Notifications
You must be signed in to change notification settings - Fork 9
/
plugin.py
248 lines (227 loc) · 12.4 KB
/
plugin.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
"""
UPS Monitor python plugin for Domoticz
Author: Logread, adapted from the NUT utilities (see Network UPS Tools project at http://networkupstools.org/)
Version: 0.0.1: alpha
0.0.2: beta, changed status device to Alert v.s. multilevel switch with alarm icon
0.1.0: 1st stable version
0.1.1: small bux fix, edit incorrect some devices labels (AC v.s. DC)
0.1.2: code change to avoid bug that appeared with domoticz version 3.8035
(devices no longer can be created and updated in the same pass
0.1.3: code cleanup
0.2.0: added a more comprehensive list of NUT status variables. Thanks to domoticz forum user @ycahome
0.2.1: in case of communication error or invalid data received, stop updating devices (thanks
to domoticz forum user @hamster) and mark the status device as "timed out" to display in red in GUI
0.2.2: added authentication option (thanks to domoticz forum user @copernicnic)
0.2.3: fixed incorrect indent
"""
"""
<plugin key="NUT_UPS" name="UPS Monitor" author="logread" version="0.2.3" wikilink="http://www.domoticz.com/wiki/plugins/NUT_UPS.html" externallink="http://networkupstools.org/">
<params>
<param field="Address" label="UPS NUT Server IP Address" width="200px" required="true" default="127.0.0.1"/>
<param field="Port" label="Port" width="40px" required="true" default="3493"/>
<param field="Username" label="Username" width="200px" required="false" default=""/>
<param field="Password" label="Password" width="200px" required="false" default=""/>
<param field="Mode1" label="UPS NUT name" width="200px" required="true" default="ups"/>
<param field="Mode6" label="Debug" width="75px">
<options>
<option label="True" value="Debug"/>
<option label="False" value="Normal" default="true" />
</options>
</param>
</params>
</plugin>
"""
import Domoticz
import telnetlib
from datetime import datetime, timedelta
class BasePlugin:
def __init__(self):
self.debug = False
self.error = True
self.timeoutversion = False
self.timeout = False
self.nextpoll = datetime.now()
self.pollinterval = 60 #Time in seconds between two polls
self.variables = {
# key: [device label, unit, value, device number, used by default]
"ups.status": ["UPS Status", "", 0, 1, 1],
"battery.charge": ["UPS Charge", "%", None, 2, 1],
"battery.runtime": ["UPS Backup Time", "s", None, 3, 1],
"input.voltage": ["UPS AC Input", "V", None, 4, 0],
"ups.load": ["UPS Load", "%", None, 5, 0],
"ups.realpower": ["UPS Power", "W", None, 6, 0],
"input.frequency": ["UPS AC Frequency", "Hz", None, 7, 0]
}
self.status = {
#code (display, alarm level)
"OL": ("ONLINE", 1), # On line (mains is present)
"OB": ("ONBATTERY", 4), # On battery (mains is not present)
"LB": ("LOWBATTERY", 4), # Low battery
"HB": ("HIGHBATTERY", 1), # High battery
"RB": ("REPLACEBATTERY", 3), # The battery needs to be replaced
"CHRG": ("CHARGING", 1), # The battery is charging
"DISCHRG": ("DISCHARGING", 3), # The battery is discharging (inverter is providing load power)
"BYPASS": ("BYPASS", 3), # UPS bypass circuit is active - no battery protection is available
"CAL": ("CALLIBRATION", 1), # UPS is currently performing runtime calibration (on battery)
"OFF": ("OFF", 0), # UPS is offline and is not supplying power to the load
"OVER": ("OVERLOAD", 4), # UPS is overloaded
"TRIM": ("SMARTTRIM", 3), # UPS is trimming incoming voltage (called "buck" in some hardware)
"BOOST": ("BOOST", 3), # UPS is boosting incoming voltage
"FSD": ("FORCE_SHUTDOWN", 4) # Forced Shutdown
}
self.statusflags = []
self.alert = 0
self.telnettimeout = 2 # seconds
return
def onStart(self):
Domoticz.Debug("onStart called")
if Parameters["Mode6"] == 'Debug':
self.debug = True
Domoticz.Debugging(1)
DumpConfigToLog()
else:
Domoticz.Debugging(0)
# create the mandatory child device if it does not yet exist
if 1 not in Devices:
Domoticz.Device(Name="UPS Status Mode", Unit=1, TypeName="Alert", Used=1).Create()
Devices[1].Update(nValue=0, sValue="") # Grey icon to reflect not yet polled
# check if our version of domoticz supports the "TimedOut" device attribute (I cannot remember which version of
# domoticz has this implemented, so best is to check if supported by "trial and error" method)
try:
temp = Devices[1].TimedOut
except AttributeError:
self.timeoutversion = False
else:
self.timeoutversion = True
def onStop(self):
Domoticz.Debug("onStop called")
Domoticz.Debugging(0)
def onHeartbeat(self):
now = datetime.now()
if now >= self.nextpoll:
self.nextpoll = now + timedelta(seconds=self.pollinterval)
# poll the NUT UPS server
try:
nut = telnetlib.Telnet(host=Parameters["Address"], port=Parameters["Port"], timeout=5)
except Exception as errorcode:
Domoticz.Error("Cannot communicate with NUT Server at {}:{} due to {}".format(
Parameters["Address"], Parameters["Port"], errorcode.args))
self.error = True
self.UpdateDevice("ups.status") # we flag the error to the status device
else:
# proceed with authentication if parameters are present
if Parameters["Username"] != "" and Parameters["Password"] != "":
try:
nut.write(bytes("USERNAME %s\n" % Parameters["Username"], "utf-8"))
result = nut.read_until(b"\n", self.telnettimeout).decode()
if result[:2] != "OK":
raise Exception(result.replace("\n", ""))
nut.write(bytes("PASSWORD %s\n" % Parameters["Password"], "utf-8"))
result = nut.read_until(b"\n", self.telnettimeout).decode()
if result[:2] != "OK":
raise Exception(result.replace("\n", ""))
except Exception as errorcode:
Domoticz.Error("Authentication error: {}".format(errorcode.args))
self.error = True
self.UpdateDevice("ups.status") # we flag the error to the status device
nut.close()
return
# read NUT variables
nut.write(bytes("LIST VAR {}\n".format(Parameters["Mode1"]), "utf-8"))
response = nut.read_until(b"\n", self.telnettimeout).decode()
if response == "BEGIN LIST VAR {}\n".format(Parameters["Mode1"]):
response = nut.read_until(bytes("END LIST VAR {}\n".format(Parameters["Mode1"]), "utf-8"),
self.telnettimeout).decode()
offset = len("VAR {} ".format(Parameters["Mode1"]))
end_offset = 0 - (len("END LIST VAR %s\n" % Parameters["Mode1"]) + 1)
for current in response[:end_offset].split("\n"):
key = str(current[offset:].split('"')[0].replace(" ", ""))
data = current[offset:].split('"')[1]
if key in self.variables:
self.variables[key][2] = data
self.error = False
else:
Domoticz.Error("Error reading UPS variables: {}".format(response.replace("\n", "")))
self.error = True
nut.close()
self.statusflags = [] # reset status flags list
self.alert = 0 # reset alarm level to 0
for key in self.variables:
Domoticz.Debug("Variable {} = {}".format(self.variables[key][0], self.variables[key][2]))
if self.variables[key][2]: # skip any variables not reported by the NUT server
self.UpdateDevice(key) # create/update the relevant child devices
def UpdateDevice(self, key):
# inner function to perform the actual update
def DoUpdate(Unit=0, nValue=0, sValue="", TimedOut=0):
try:
if self.timeoutversion: # Device attribute TimeOut exists in the host domoticz version or not
Devices[Unit].Update(nValue=nValue, sValue=sValue, TimedOut=TimedOut)
else:
Devices[Unit].Update(nValue=nValue, sValue=sValue)
except Exception as errorcode:
Domoticz.Error("Failed to update device unit {} due to {}".format(Unit, errorcode.args))
# Make sure that the Domoticz device still exists (they can be deleted) before updating it
if self.variables[key][3] in Devices:
if key == "ups.status":
if self.error:
nvalue = 0
svalue = "COMMUNICATION ERROR"
timedout = True
else:
# iterate over the codes in the status string
for word in self.variables[key][2].split(" "):
try:
temp = self.status[word]
except KeyError:
# code not in our list of possible statuses... do not "translate" but report as is
self.statusflags.append(str(word))
else:
# code is known so translated and alert level updated accordingly
self.statusflags.append(self.status[word][0])
self.alert = max(self.alert, self.status[word][1])
nvalue = self.alert
svalue = " ".join(self.statusflags)
timedout = False
if timedout != self.timeout:
self.timeout = timedout
timedoutchange = True
else:
timedoutchange = False
if Devices[self.variables[key][3]].sValue != svalue or timedoutchange:
DoUpdate(self.variables[key][3], nvalue, svalue, timedout)
else:
if not self.error:
nvalue = 0
svalue = str(self.variables[key][2])
DoUpdate(self.variables[key][3], nvalue, svalue)
elif key != "ups.status":
Domoticz.Device(Name=self.variables[key][0], Unit=self.variables[key][3], TypeName="Custom",
Image= 17, Options={"Custom": "1;{}".format(self.variables[key][1])},
Used=self.variables[key][4]).Create()
# Update upon next poll (recursive call to update device broken in some domoticz versions)
global _plugin
_plugin = BasePlugin()
def onStart():
global _plugin
_plugin.onStart()
def onStop():
global _plugin
_plugin.onStop()
def onHeartbeat():
global _plugin
_plugin.onHeartbeat()
# Plugin specific functions ---------------------------------------------------
# Generic helper functions
def DumpConfigToLog():
for x in Parameters:
if Parameters[x] != "":
Domoticz.Debug( "'" + x + "':'" + str(Parameters[x]) + "'")
Domoticz.Debug("Device count: " + str(len(Devices)))
for x in Devices:
Domoticz.Debug("Device: " + str(x) + " - " + str(Devices[x]))
Domoticz.Debug("Device ID: '" + str(Devices[x].ID) + "'")
Domoticz.Debug("Device Name: '" + Devices[x].Name + "'")
Domoticz.Debug("Device nValue: " + str(Devices[x].nValue))
Domoticz.Debug("Device sValue: '" + Devices[x].sValue + "'")
Domoticz.Debug("Device LastLevel: " + str(Devices[x].LastLevel))
return