the heatport is only used to dump energy that otherwise would be lost in normalization, which is confusing and not necessary and can be seen as a historic artefact of the compontent.
Either remove the heatport or connect it to the fluid by a heat-conductance.
The text was updated successfully, but these errors were encountered:
the heatport is only used to dump energy that otherwise would be lost in normalization, which is confusing and not necessary and can be seen as a historic artefact of the compontent.
Either remove the heatport or connect it to the fluid by a heat-conductance.