Create a plan for pressure jump experiment #79
Comments
tagging @barnettwilliam for reference |
@stan-dot I can't modify the list to add this: |
added |
initial draft of devices needed
plan parameters
|
base rate - some detectors going at different frequencies haven't considered how to make a generic plan doing that. tfg atm does not do multiples of the base rate (???) but no gui for this camera is the slowest (up to 20Hz), pilatuses (up to 250Hz), and tetramm (20kHz) have the same frame time |
what parameters? Pilatus exposure time should be the main reference point Tetramm is set to match Pilatus Can we run an optical camera at some divisor of the Pilatus rate, so we choose an integer close to 20Hz?? but the image could be ruined, intensity must be sensible so that it's not over- or under- saturated |
we can do a small test plan in order to make the pressure cell work |
meeting notespressure - just 1 jump very the initial pressure 150-250 1500-3000 with 2000 the main vlaue 10s, jump, (5s, more captures high resolution), 10s after both tetramms (i0, it) and waxs and saxs vaery from 5 seconds to 10 minutes shouldn't be outside those bounds |
based on the confluence docs page.
We need to create sub-issues for this epic. We need to: