Create a plan for pressure jump experiment #79

Open
2 of 4 tasks
stan-dot opened this issue Jul 3, 2024 · 8 comments · May be fixed by #97
Open
2 of 4 tasks

Create a plan for pressure jump experiment #79

stan-dot opened this issue Jul 3, 2024 · 8 comments · May be fixed by #97
Assignees

Comments

@stan-dot
Copy link
Collaborator

stan-dot commented Jul 3, 2024

based on the confluence docs page.

We need to create sub-issues for this epic. We need to:

@stan-dot stan-dot assigned stan-dot and unassigned stan-dot Jul 3, 2024
@stan-dot
Copy link
Collaborator Author

stan-dot commented Jul 4, 2024

tagging @barnettwilliam for reference

@barnettwilliam
Copy link

@stan-dot I can't modify the list to add this:
create pressure cell ophyd device DiamondLightSource/dodal#658

@stan-dot
Copy link
Collaborator Author

stan-dot commented Jul 5, 2024

added

@stan-dot
Copy link
Collaborator Author

stan-dot commented Jul 9, 2024

initial draft of devices needed

  • valve
  • pressure controller
  • detector

plan parameters

  • initial pressure
  • final pressure
  • number of captures before the jump
  • number of captures after the jump
  • ???

@stan-dot
Copy link
Collaborator Author

stan-dot commented Jul 9, 2024

base rate - some detectors going at different frequencies

haven't considered how to make a generic plan doing that.
one of the deliverables is to replace tfg, so will need a generic scan plan.

tfg atm does not do multiples of the base rate (???) but no gui for this

camera is the slowest (up to 20Hz), pilatuses (up to 250Hz), and tetramm (20kHz) have the same frame time

@stan-dot
Copy link
Collaborator Author

stan-dot commented Jul 9, 2024

what parameters?
nominal exposure times (per detector (?))
OAV only ever an ancillary measurement, but unfortunately it is the slowest

Pilatus exposure time should be the main reference point

Tetramm is set to match Pilatus

Can we run an optical camera at some divisor of the Pilatus rate, so we choose an integer close to 20Hz??

but the image could be ruined, intensity must be sensible so that it's not over- or under- saturated

@stan-dot
Copy link
Collaborator Author

we can do a small test plan in order to make the pressure cell work

@stan-dot
Copy link
Collaborator Author

meeting notes

pressure - just 1 jump

very the initial pressure 150-250
linspace

1500-3000 with 2000 the main vlaue

10s, jump, (5s, more captures high resolution), 10s after

both tetramms (i0, it) and waxs and saxs

vaery from 5 seconds to 10 minutes

shouldn't be outside those bounds

@stan-dot stan-dot linked a pull request Aug 22, 2024 that will close this issue
@stan-dot stan-dot changed the title Create a plan for November pressure jump experiment Create a plan for# pressure jump experiment Aug 29, 2024
@stan-dot stan-dot changed the title Create a plan for# pressure jump experiment Create a plan for pressure jump experiment Aug 29, 2024
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

Successfully merging a pull request may close this issue.

2 participants