Notifications
You must be signed in to change notification settings - Fork 37
/
autofertilizermod.py
executable file
·104 lines (87 loc) · 3.87 KB
/
autofertilizermod.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
from __future__ import print_function
import logging
from datetime import datetime, date ,timedelta
import time
import hardwaremod
import os
import subprocess
import emailmod
import autofertilizerdbmod
import sensordbmod
import actuatordbmod
import fertilizerdbmod
import statusdataDBmod
import ActuatorControllermod
logger = logging.getLogger("hydrosys4."+__name__)
# status array, required to check the ongoing actions within a watering cycle
elementlist= autofertilizerdbmod.getelementlist()
AUTO_data={} # dictionary of dictionary
#for element in elementlist:
# AUTO_data[element]={"triggerdate":datetime.utcnow(),"tobeactivated":False, "duration":0, "alertcounter":0}
AUTO_data["default"]={"triggerdate":datetime.utcnow(),"tobeactivated":False, "duration":0, "alertcounter":0}
# triggerdate, datetime when the doser have been triggered to start
# tobeactivated, doser need to be activated in the next opportunity
def isschedulermode(element):
recordkey="element"
recordvalue=element
keytosearch="workmode"
workmode=autofertilizerdbmod.searchdata(recordkey,recordvalue,keytosearch)
if workmode=="SceduledTime":
return True
else:
return False
def checkactivate(elementwater,durationwater): # requires integer input
elementlist=fertilizerdbmod.getelementlist()
waterok=False
for doserelement in elementlist: # provided the waterelement, search for corresponding doserelement
linkedwaterelement=autofertilizerdbmod.searchdata("element",doserelement,"waterZone")
if linkedwaterelement==elementwater:
waterok=True
element=doserelement
break
if waterok: # there is a corresponding doser element
minwaterduration=hardwaremod.toint(autofertilizerdbmod.searchdata("element",element,"minactivationsec"),0)
if not isschedulermode(element): #setup is not for scheduled time
print(" Fertilizer " ,element ," set to autowater")
print(" Check Water duration ", durationwater ,">", minwaterduration)
if durationwater>minwaterduration: # watering time above the set threshold
print(" OK Water duration ")
if statusdataDBmod.read_status_data(AUTO_data,element,"tobeactivated"): #if flag is ON
print(" Activate ", element)
durationfer=statusdataDBmod.read_status_data(AUTO_data,element,"duration")
activatedoser(element,durationfer)
time.sleep(durationfer) #this blocks the system (and watering activation) for n seconds ... not best practice
else:
print(" No pending request to activate ", element)
def activatedoser(element, duration):
print(element, " ",duration, " " , datetime.now())
logger.info('Doser Pulse, pulse time for ms = %s', duration)
msg, pulseok = ActuatorControllermod.activateactuator(element,duration)
# msg , pulseok=hardwaremod.makepulse(element,duration)
# salva su database
actuatordbmod.insertdataintable(element,duration)
# put flag down
global AUTO_data
statusdataDBmod.write_status_data(AUTO_data,element,"tobeactivated",False)
statusdataDBmod.write_status_data(AUTO_data,element,"duration",0)
statusdataDBmod.write_status_data(AUTO_data,element,"triggerdate",datetime.now())
def setActivationDurationDate(element,tobeactivated,duration,triggerdate):
global AUTO_data
statusdataDBmod.write_status_data(AUTO_data,element,"tobeactivated",tobeactivated) #true or false
statusdataDBmod.write_status_data(AUTO_data,element,"duration",duration)
statusdataDBmod.write_status_data(AUTO_data,element,"triggerdate",triggerdate)
def checkworkmode(element):
return autofertilizerdbmod.searchdata("element",element,"workmode")
def timelist(element):
if isschedulermode(element):
fertime=autofertilizerdbmod.searchdata("element",element,"time")
print("fertime " , fertime)
timelist=hardwaremod.separatetimestringint(fertime)
else:
print("non scheduler mode ")
timelist=hardwaremod.separatetimestringint("00:20:00") # get up 0 minutes and check for doseractivation
return timelist
if __name__ == '__main__':
"""
prova functions
"""