Update calibrations to compile against (newer) newest version of CERN ROOT.
The string concat '+' operator fails in hodoscope calibration.
Correct hard coded cuts on TDCs for hodoscope timing.

Make TDC plots so people select the true hits in the hodo trigger TDC.
Remove the count on number of planes hit in DC for double peaking in DC during high rate running:
//Count how many planes were hit by the event
Make it clear for setting timing windows and reference times which DBASE file and PARAMs are used.
There is a line added to the plots with no timing window or reftime cuts. These read from the gHcParms list. If the DBASE file is wrong, this will show the user incorrect cuts.
Remove or archive calibrations that are no longer used.