My Baxi Nuvola DUO-TEC HT 16 boiler works well If I have heating turn on (climate.opentherm_heating), but boiler don't heating (i use ON/OFF + zone heating valves), the pump is still running. |
Thanks for the info!
Yes, in this mode the boiler will simply maintain the set coolant temperature. Just as if you had set it from the boiler control panel.
Hmm, I think you can turn off the heating using automation in the home assistant. Turning off the heating should turn off the pump. In my system, just like yours, installed electric valves to accurately regulate the temperature in the zones. And I use equitherm mode. This prevents the heating system from swinging. Try this. |
Котел: Ferroli DOMIcompact C 24 (плата MF08FA) Master Member ID: 211 Конфиг: WEMOS D1 MINI + DIYLESS Master OpenTherm Shield + датчик Xiaomi LYWSD03MMC (через MQTT отсылаю температуру в топик) + DS18B20 на улице (так же в топик через MQTT). Ссылки кликабельные, для тех кто решит повторить мой опыт с таким же котлом Логика работы: Эквитерм (PID не пробовал) Не работающие сенсоры: Pressure (показывает нули) Fault code: при необходимых условиях работает Все остальное работает корректно:
Работает просто отлично, я прям не ожидал что будет все так просто (котел то довольно старый, 2005 год, думал что вообще не заведется). Сначала прошил собранную прошивку 1.3.1, но не сохранялись настройки MQTT после перезагрузки (еще до того как вы выложили по d1 mini), потом досмотрел что это для d1 mini pro и собрал через Platformio, стало все нормально. Раньше до этого пользовался реле с сухими контактами, а сейчас уже 5 день как пользуюсь вашей прошивкой, так что статистики пока мало. Да и холодов особо не было, до 5 градусов максимум. но температуру держит хорошо, теперь главное как с расходом. Оффтоп по потреблениюПо замерам на минимуме модуляции (2%) потребляет где-то 0.75 куба газа в час, на максимуме (100%) выходит 1.5 куба (хотя по паспорту должно до 2.73 куба, то ли газ такой сейчас в Украине, то ли так настроена подача газа в котле). Теперь как бы сделать сенсор в Home assistant, который будет рассчитывать потребление газа брав данные из сенсора модуляции, по логике: с 2% до 50% модуляции это 0,75 куба, а с 50 до 100% это уже 1.5 куба, так как счетчика отдельного на котел нет и замеры проводились с секундомером и точно не могу посчитать, так как нет возможности самому регулировать модуляцию и точно высчитать сколько газа потребляет в на каждой ступеньке с 2 до 100%, а так хоть будет примерное понимание. Сейчас сделал по гайду (настраивал еще под реле с сухими контактами) и поставил 1 куб в час при работе отопления и горелки. Кстати по его же методике балансировал радиаторы отопленияБольшое спасибо за ваш труд! |
This comment was marked as off-topic.
This comment was marked as off-topic.
This comment was marked as off-topic.
This comment was marked as off-topic.
This comment was marked as off-topic.
This comment was marked as off-topic.
This comment was marked as off-topic.
This comment was marked as off-topic.
This comment was marked as off-topic.
This comment was marked as off-topic.
This comment was marked as off-topic.
This comment was marked as off-topic.
This comment was marked as off-topic.
This comment was marked as off-topic.
This comment was marked as off-topic.
This comment was marked as off-topic.
Hello, One question: is there any particular reason why you set DHW temperature to zero when DHW is off? It would be nice to have this reading all the time, because in my case it shows the water reservoir temperature. Best regards, |
@menuet88, thanks for the info!
I'll fix this in the next version.
I thought about it. But I decided to leave it as is. Because different boilers have different software. We can break the logic of the controller on boilers that do not fully implement the opentherm specification. |
Даже с некорректным member master id котёл должен отвечать на базовые запросы. Подбирают методом перебора, но это необходимо только в том случае, если котлом не получается управлять (менять температуру и т.п.) Если у вас вообще котел не отвечает, проверьте в настройках пины OT. Иногда помогает поменять их местами. |
Offtop
Здравствуйте Данные берутся с фото счетчика, оцифровываются и выгружаются по mqtt в HA. Можно смотреть статистику по часам, дням, неделям, месяцам, годам.. По OTGateway. Данные о внешней температуре получаю с датчика котла. Также немного переделал код в части встроенного датчика температуры на контроллере Opentherm. У меня DS18B20 примотан к трубе обратки около самого котла и в HA передается температура обратки тоже. Пока на улице +7 градусов, поэтому такое частое тактование. Котел 31 квт излишен для моего дома при такой положительной температуре. Я ставлю минималку 45 градусов. Котел не может её поддерживать и когда до +50 градусов набирает температуру, то выключает горелку. |
@bigbrother72, благодарю за информацию. А зачем снимать температуру обратки, если мы на нее нигде не ориентируемся? |
@aurelmarius thanks for the info! |
Hello All, I am facing issues with existing thermostat BAXI connected to slave shield - it reports error 83 as can be seen on attached photos: Anyone could help on slave-thermostat side? Thank you for your help |
@kerajkeraj it won't work the way you want. The baxi thermostat is the master, the firmware from this repository is also the master, and the boiler is the slave. We could probably intercept requests to set the temperature and not pass them on to the boiler. But I don't have a thermostat to test this. |
Boiler: Radiant R2KA |
Intergas Kombi Kompakt working fine with Diyless Thermostat shield. Combi boiler, so hot water is on demand only. All parameter (relevant to me) reporting / being set correctly. Master ID = 0. |
Baltur Tesis 24 works. |
I have assembled a DIYLESS Thermostat shield with a D1 Mini and installed version 1.3.3 It works with my Domusa Bioclass HM 16 pellet boiler. I have left the master ID with value 0 (default) Almost everything works, DHW, correct. Diagnostics, fault messages, etc. ok. But I don't see the % modulation, my old Tado showed me that value. Is there any way to see it? I'm interested to see if the modulation works well. I don't see the value of pressure either. On the other hand, wouldn't it be more correct to show the HW controller in HA as water_heater entity and not as climate? |
@MikelillOi thanks for the info! Modulation and pressure entities are not activated by default. You need to activate them in Home Assistant. |
This comment was marked as off-topic.
This comment was marked as off-topic.
This comment was marked as off-topic.
This comment was marked as off-topic.
Mizudo 24mth, Master MemberID 0, уличная температура подтягивается с датчика котла, температуру дома взял с BLE через автоматизацию НА, температуру косвенника (ГВС) тоже с котла, прошивка v1.4.0-rc.17, собрал на d1, в НА стандартная карта, плюс добавил автоматизацию по темп ГВС, CO отрабатывает по еквитерм. Можно добавить еще, что модуляция отрабатывается сейчас на 3% (температура на улицк 0 -2). Ранее при подключении к котлу обычного термостата модуляция начиналась где-то с 10%, судя по дисплею котла. |
This comment was marked as off-topic.
This comment was marked as off-topic.
This comment was marked as off-topic.
This comment was marked as off-topic.
This comment was marked as off-topic.
This comment was marked as off-topic.
This comment was marked as off-topic.
This comment was marked as off-topic.
Котел: Baxi Eco 5 Compact |
Котел: De Dietrich PMC-M 24/28MI PLUS Не работающие сенсоры: Fault code: коректно показывал ошибку E36, так же как термостат (De Dietrich AD 289) Все остальное работает корректно: Большое спасибо! |
Hi, |
This comment was marked as off-topic.
This comment was marked as off-topic.
Hi @Saur0o0n |
Спасибо за проделанную работу!
Замечания:
Предложения:
|
Hi! |
@gunarser thx for the info. It's normal, when you disable PID and Equitherm, you control the heating temperature, not the indoor temperature. For questions create a new issue:
|
Thanks for the explanation! It makes total sense.
|
Please create an issue and upload logs. |
hi I have the same boiler and I'm not able to Disable the DWH for example. Is it working for you? |
Hey, First - thanks for the work creating this. Boiler: Immergas Victrix Zeus 25 All stock settings used - apart from enabling 'Fix for Immergas boilers' Key functions are working fine it seems. DHW flow rate is not working (values are not changing) - any ideas what I could try? |
I can confirm that the B1hc from Viessmann works as quoted above. But it also allows use of the weather compensation external thermometer if installed in x21 cable slots 3 and 4, with the open therm contacts being used by the opentherm gateway in slots 1 and 2 of the x21 area. now I just need to figure out how to use PID…because it is there, looking at me. |
Veissmann 100w-B1hc 30Kwh limited to 14Kwh max Output, system boiler with priority dhw. mistakes I made: Settings: Opentherm settings: (checked boxes) |
Hi there |
Hi there! плата согласования с котлом: Прошивку скачал здесь: https://github.com/Laxilef/OTGateway/releases/tag/1.4.6 программа прошивальщик: Если все сделали правильно, то на ESP загорятся светодиодики и она может быть доступна по WiFI. Подключаемся к ESP по WiFi компом или телефоном к сети с названием :otgateway что-то там, пароль: otgateway123456. Заходим на IP:192.168.4.1 и попадаем на страницу с первоначальными настройками, где уже вносим название своей сети и свой пароль от WiFi. Перезагружаемся. После этого ESP по адресу 192.168.4.1 уже будет не доступна. Необходимо установить статический ip из пула адресов, выдаваемых вашим домашним роутером нашей платке. Для этого нужно зайти на свой домашний роутер с админом и паролем (по дефолту у роутеров admin/admin ), найти ip присвоенный роутером нашей ESP после внесенных изменений и ее перезагрузке и в настройках DHSP зафиксировать ip по MAC адресу ESP. Это нужно для того, чтобы при перезагрузке или при отключении света роутер опять присвоил плате тот же ip. Отключаем шнурок от компа, если ESP была подключена к нему. Далее плату подключаем к питанию, достаточно зарядника от мобильника 300 ват. Отключаем котел с панели, обесточиваем, вставляем 2-а провода OpenTerm в нашу платку, сечением не менее 0,5mm каждый. Другой конец вставляем в котел. У моего котла это контакты 40, 41 вместо перемычки, полярность не имеет значения. Подключаем котел к сети, ждем включения, если зимний режим не был включен, то включаем его с панельки котла. Температуру отопления на панельке котла выставляем ближе к максимальной. Должно все заработать. Светодиоды красный и синий должны гореть постоянно. Если синий моргает, то связь по ОпенТерм отсутствует. |
Please write here the name of your boiler and its compatibility features (what works, what doesn’t work).
I will add to the table in README.
This will be very useful for other people. Thanks!
Please do not ask questions in this issue; to do this, you can open a new issue or ask a question in telegram chat.
This issue is ONLY for reports on the work of boilers with firmware.
The text was updated successfully, but these errors were encountered: