Boiler Immergas Victrix Zeus 25 #92

Open
VladaWaas opened this issue Nov 13, 2024 · 13 comments
Open

Boiler Immergas Victrix Zeus 25 #92

VladaWaas opened this issue Nov 13, 2024 · 13 comments
Labels

Comments

@VladaWaas
Copy link

Actualy status:
Snímek obrazovky 2024-11-13 102957
This is compatible points with OpenTherm:
zeus25
Could you add points: 19,77 and 85 to your firmware?
Thank you in adwance.
Vladimir

@Laxilef
Copy link
Owner

Laxilef commented Nov 13, 2024

Hi,

ID 19 - DHW flow rate, it is already supported.
What do ID 77 and 85 mean for your boiler?

@VladaWaas
Copy link
Author

VladaWaas commented Nov 13, 2024

Hello,
thx for fast respose. ID19- flow rate is permanently zero on interface. Can I have any mistake in my setup?
ID 77 represented intake relative ventilation level 0-100%
ID 85 represented actual inlet fan speed in rpm

I don't necessarily need the last two values, but I thought why not show them if there was an option. :D

I have one more question about setting the equithermal constants.
I have
N = 1.2
K = 0.1
T=2
instead of power modulation, the boiler is switched off after reaching T-in 22°
which constant should I correct?

@Laxilef
Copy link
Owner

Laxilef commented Nov 13, 2024

I will add polling ID 85 to the new version.

I have one more question about setting the equithermal constants.

https://github.com/Laxilef/OTGateway/wiki#fit-coefficients

@Laxilef
Copy link
Owner

Laxilef commented Nov 13, 2024

ID19- flow rate is permanently zero on interface. Can I have any mistake in my setup?

Well, not all boilers report this parameter.

@VladaWaas
Copy link
Author

ID19- flow rate is permanently zero on interface. Can I have any mistake in my setup?

Well, not all boilers report this parameter.

Immergas is not in the OpenTherm association, but its extension modules are based on OpenTherm protocols. According to a non-public information from their developer, ID 19 should be active. But it is possible that the query string may differ in some small way from the OT spec.

@VladaWaas
Copy link
Author

I will add polling ID 85 to the new version.

Thank you!

I have one more question about setting the equithermal constants.

https://github.com/Laxilef/OTGateway/wiki#fit-coefficients

I reading it last week. I did exactly according to your instructions immediately after installation. But I'm a pretty impatient person. Any intervention in the system has a long inertia. I will have to improve! :))))

@Laxilef
Copy link
Owner

Laxilef commented Nov 13, 2024

Immergas is not in the OpenTherm association, but its extension modules are based on OpenTherm protocols. According to a non-public information from their developer, ID 19 should be active. But it is possible that the query string may differ in some small way from the OT spec.

Hmm, in the firmware we interpret response as float. Can you open the hot water tap and start logging?

@VladaWaas
Copy link
Author

Immergas is not in the OpenTherm association, but its extension modules are based on OpenTherm protocols. According to a non-public information from their developer, ID 19 should be active. But it is possible that the query string may differ in some small way from the OT spec.

Hmm, in the firmware we interpret response as float. Can you open the hot water tap and start logging?

yes I do. Can I acces via telnet in debug mode?

@VladaWaas
Copy link
Author

putty.log

@Laxilef
Copy link
Owner

Laxilef commented Nov 14, 2024

ID: 19 Request: 80130000 Response: 70130000 Attempt: 1 Status: INVALID
Your boiler responds with INVALID response to DHW flow rate request

@VladaWaas
Copy link
Author

yes i noticed it as soon as i opened telnet. But I don't want to give up yet. I will ask the developer technician from the manufacturer if it is the same request at Imerrgas as specified by opentherm. Can you please send me the script of your command to fetch the values?

@VladaWaas
Copy link
Author

so I don't have positive information :(
ID19 is active only in models with direct flow heating without a hot water storage tank

Copy link
Contributor

This issue is stale because it has been open 15 days with no activity. Remove stale label or comment or this will be closed in 5 days.

@github-actions github-actions bot added the Stale label Nov 30, 2024
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
Projects
None yet
Development

No branches or pull requests

2 participants