Notifications
You must be signed in to change notification settings - Fork 1
/
Copy pathZigSwitchPlus.groovy
131 lines (114 loc) · 5.56 KB
/
ZigSwitchPlus.groovy
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
/**
* Zigbee switch augmented with Momentary (pulse) capability for use with garage opener switches and such
* The device type handler once installed, will allow you to configure the pulse length in seconds (min 1)
* Note: Be sure to configure it, as the pulsing otherwise won't work.
*
* Mod by Max Ranzau ([email protected])
* Use at your own risk, blah-di-blah-boilerplate-disclaimer.
*/
metadata {
definition (name: "ZigBee Switch PLUS", namespace: "MaxVonEvil", author: "MaxVonEvil", ocfDeviceType: "oic.d.switch", runLocally: false, minHubCoreVersion: '000.019.00012', executeCommandsLocally: true) {
capability "Actuator"
capability "Configuration"
capability "Refresh"
capability "Switch"
capability "Health Check"
capability "Momentary"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0006", outClusters: "0003, 0006, 0019, 0406", manufacturer: "Leviton", model: "ZSS-10", deviceJoinName: "Leviton Switch"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0006", outClusters: "000A", manufacturer: "HAI", model: "65A21-1", deviceJoinName: "Leviton Wireless Load Control Module-30amp"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006", outClusters: "0003, 0006, 0008, 0019, 0406", manufacturer: "Leviton", model: "DL15A", deviceJoinName: "Leviton Lumina RF Plug-In Appliance Module"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006", outClusters: "0003, 0006, 0008, 0019, 0406", manufacturer: "Leviton", model: "DL15S", deviceJoinName: "Leviton Lumina RF Switch"
fingerprint profileId: "C05E", inClusters: "0000, 0003, 0004, 0005, 0006, 1000, 0B04, FC0F", outClusters: "0019", manufacturer: "OSRAM", model: "Plug 01", deviceJoinName: "OSRAM SMART+ Plug"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0B05, FC01, FC08", outClusters: "0003, 0019", manufacturer: "LEDVANCE", model: "PLUG", deviceJoinName: "SYLVANIA SMART+ Smart Plug"
}
// simulator metadata
simulator {
// status messages
status "on": "on/off: 1"
status "off": "on/off: 0"
// reply messages
reply "zcl on-off on": "on/off: 1"
reply "zcl on-off off": "on/off: 0"
}
tiles(scale: 2) {
multiAttributeTile(name:"switch", type: "lighting", width: 6, height: 4, canChangeIcon: true){
tileAttribute ("device.switch", key: "PRIMARY_CONTROL") {
attributeState "on", label:'${name}', action:"switch.off", icon:"st.switches.light.on", backgroundColor:"#00A0DC", nextState:"turningOff"
attributeState "off", label:'${name}', action:"switch.on", icon:"st.switches.light.off", backgroundColor:"#ffffff", nextState:"turningOn"
attributeState "turningOn", label:'${name}', action:"switch.off", icon:"st.switches.light.on", backgroundColor:"#00A0DC", nextState:"turningOff"
attributeState "turningOff", label:'${name}', action:"switch.on", icon:"st.switches.light.off", backgroundColor:"#ffffff", nextState:"turningOn"
}
}
standardTile("push", "device.push", inactiveLabel: false, decoration: "flat", width: 2, height: 2) {
state "default", label:"Pulse", action:"momentary.push", icon:"st.secondary.activity"
}
standardTile("refresh", "device.refresh", inactiveLabel: false, decoration: "flat", width: 2, height: 2) {
state "default", label:"", action:"refresh.refresh", icon:"st.secondary.refresh"
}
main "switch"
details(["switch", "push","refresh"])
}
preferences {
input "pulseLength", "number",
title: "Length of pulse (Seconds)",
description: "Number of seconds to close the switch before opening it again. Minimum value is 1. Maximum is 7200 (2 hours)",
defaultValue: 1,
range: "1..7200",
displayDuringSetup: false,
required: true
input "debugOutput", "bool",
title: "Enable debug logging?",
defaultValue: true,
displayDuringSetup: false,
required: false
}
}
// Parse incoming device messages to generate events
def parse(String description) {
log.debug "description is $description"
def event = zigbee.getEvent(description)
if (event) {
sendEvent(event)
}
else {
log.warn "DID NOT PARSE MESSAGE for description : $description"
log.debug zigbee.parseDescriptionAsMap(description)
}
}
def off() {
logDebug "*** OFF"
zigbee.off()
}
def on() {
logDebug "*** ON"
zigbee.on()
}
// ------------------------------------------------------------------------
def push() {
def sLetter
if (settings?.pulseLength > 1) { sLetter = "s." } else { sLetter = "." }
logDebug "*** Momentary pulse for " + settings?.pulseLength + " second" + sLetter
delayBetween([
zigbee.on(),
zigbee.off()
], (settings?.pulseLength * 1000))
}
// PING is used by Device-Watch in attempt to reach the Device
def ping() {
return refresh()
}
def refresh() {
zigbee.onOffRefresh() + zigbee.onOffConfig()
}
def configure() {
// Device-Watch allows 2 check-in misses from device + ping (plus 2 min lag time)
sendEvent(name: "checkInterval", value: 2 * 10 * 60 + 2 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
logDebug "Configuring Reporting and Bindings."
zigbee.onOffRefresh() + zigbee.onOffConfig()
}
private logDebug(msg) {
if (settings?.debugOutput || settings?.debugOutput == null) {
log.debug "$msg"
}
}