title | description | addedAt | pageClass |
---|---|---|---|
Plugwise 106-03 control via MQTT |
Integrate your Plugwise 106-03 via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway. |
2023-05-24 13:14:06 -0700 |
device-page |
Model | 106-03 |
Vendor | Plugwise |
Description | Tom thermostatic radiator valve |
Exposes | battery, pi_heating_demand, local_temperature, valve_position, force, radio_strength, calibrate_valve, linkquality |
Picture |
How to use device type specific configuration
-
temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
-
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.
Remaining battery in %, can take up to 24 hours before reported..
Value can be found in the published state on the battery
property.
It's not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 100
.
The unit of this value is %
.
Position of the valve (= demanded heat) where 0% is fully closed and 100% is fully open.
Value can be found in the published state on the pi_heating_demand
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"pi_heating_demand": ""}
.
It's not possible to write (/set
) this value.
The minimal value is 0
and the maximum value is 100
.
The unit of this value is %
.
Current temperature measured on the device.
Value can be found in the published state on the local_temperature
property.
It's not possible to read (/get
) or write (/set
) this value.
The unit of this value is °C
.
Directly control the radiator valve. The values range from 0 (valve closed) to 100 (valve fully open).
Value can be found in the published state on the valve_position
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"valve_position": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"valve_position": NEW_VALUE}
.
The minimal value is 0
and the maximum value is 100
.
How hard the motor pushes the valve. The closer to the boiler, the higher the force needed.
Value can be found in the published state on the force
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"force": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"force": NEW_VALUE}
.
The possible values are: standard
, high
, very_high
.
Transmits with higher power when range is not sufficient.
Value can be found in the published state on the radio_strength
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"radio_strength": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"radio_strength": NEW_VALUE}
.
The possible values are: normal
, high
.
Calibrates valve on next wakeup.
Value can be found in the published state on the calibrate_valve
property.
It's not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"calibrate_valve": NEW_VALUE}
.
If value equals calibrate
calibrate_valve is ON, if idle
OFF.
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It's not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.