Hei, From the message, my best guess is because you have multiple PVT regions. Due to some implementation difficulties back then, PLYSHLOG keyword can not handle multiple PVT regions. And I do not know whether we can prioritize to fix it either. Other polymer keywords should support multiple PVT regions. Please let us know if you find anything otherwise. Thanks for trying and reaching out. |
Hi again! Thank you for bringing this to attention; however, the manual displays two tables for the PLYSHLOG keyword. It is available just for one PVT table? In my model, there are eight PVT tables. |
Hei, not totally sure following your information here. In my opinion, if you you have eight PVT region, if you need PLYSHLOG keyword, you will need eight PLYSHLOG tables. Each PLYSHLOG table contain two parts.
Do you mean the two parts of one PLYSHLOG table setup? |
Thanks for the information. As I mentioned in the message above, OPM-flow had difficulties in handle multiple PLYSHLOG tables. If you have multiple PVT regions, then PLYSHLOG will not work (multiple PLYSHLOG tables are needed if you use PLYSHLOG). But other polymer keywords should work with multiple PVT regions. |
Hi!
I was working on the polymer model and encountered a problem. I'm using the standard polymer model.
this is my RUNSPEC section