Request that notifies the device to switch on or off one or several light relays, optionally with a dim-value per relay. If optional value 'index' is omitted, all relays configured as light are switched. In that case, all light relays will switch using only 1 LightValue instance for 'values'. In case the value 'index' is included, multiple instances of LightValue can be used (up to 6), each indicating a particular relay. If optional value 'dimValue' is omitted, then default values of 0 and 100 will be assumed for either 'on = false' or 'on = true'.
Response communicates status.
message SetLightRequest {
repeated LightValue values = 1; // [(nanopb).max_count = 6];
}
message SetLightResponse {
required Status status = 1;
}
message LightValue {
optional bytes index = 1; // [(nanopb).max_size = 1]; // index number of connected light (DALI), none means all connected ligts.
required bool on = 2;
optional bytes dimValue = 3; // [(nanopb).max_size = 1]; // 1 - 100 %
}
enum Status {
OK = 0;
FAILURE = 1; // general failure
REJECTED = 2; // request received in wrong state
}
Soap requests and responses sent to and from platform:
<SOAP-ENV:Envelope xmlns:SOAP-ENV="http://schemas.xmlsoap.org/soap/envelope/">
<SOAP-ENV:Header>
<OrganisationIdentification xmlns="http://www.opensmartgridplatform.org/schemas/common">LianderNetManagement</OrganisationIdentification>
<ApplicationName xmlns="http://www.opensmartgridplatform.org/schemas/common">WEB_OWNER</ApplicationName>
<UserName xmlns="http://www.opensmartgridplatform.org/schemas/common">liander gebruiker</UserName>
</SOAP-ENV:Header>
<SOAP-ENV:Body>
<ns2:SetLightRequest xmlns:ns2="http://www.opensmartgridplatform.org/schemas/publiclighting/adhocmanagement/2014/10" xmlns:ns3="http://www.opensmartgridplatform.org/schemas/common/2014/10">
<ns2:DeviceIdentification>device-01</ns2:DeviceIdentification>
<ns2:LightValue>
<ns2:On>true</ns2:On>
</ns2:LightValue>
</ns2:SetLightRequest>
</SOAP-ENV:Body>
</SOAP-ENV:Envelope>
<SOAP-ENV:Envelope xmlns:SOAP-ENV="http://schemas.xmlsoap.org/soap/envelope/">
<SOAP-ENV:Header />
<SOAP-ENV:Body>
<ns2:SetLightAsyncResponse xmlns:ns2="http://www.opensmartgridplatform.org/schemas/publiclighting/adhocmanagement/2014/10" xmlns:ns3="http://www.opensmartgridplatform.org/schemas/common/2014/10">
<ns2:AsyncResponse>
<ns3:CorrelationUid>LianderNetManagement|||device-01|||20160105121022551</ns3:CorrelationUid>
<ns3:DeviceId>device-01</ns3:DeviceId>
</ns2:AsyncResponse>
</ns2:SetLightAsyncResponse>
</SOAP-ENV:Body>
</SOAP-ENV:Envelope>
<SOAP-ENV:Envelope xmlns:SOAP-ENV="http://schemas.xmlsoap.org/soap/envelope/">
<SOAP-ENV:Header>
<OrganisationIdentification xmlns="http://www.opensmartgridplatform.org/schemas/common">LianderNetManagement</OrganisationIdentification>
<ApplicationName xmlns="http://www.opensmartgridplatform.org/schemas/common">WEB_OWNER</ApplicationName>
<UserName xmlns="http://www.opensmartgridplatform.org/schemas/common">liander gebruiker</UserName>
</SOAP-ENV:Header>
<SOAP-ENV:Body>
<ns2:SetLightAsyncRequest xmlns:ns2="http://www.opensmartgridplatform.org/schemas/publiclighting/adhocmanagement/2014/10" xmlns:ns3="http://www.opensmartgridplatform.org/schemas/common/2014/10">
<ns2:AsyncRequest>
<ns3:CorrelationUid>LianderNetManagement|||device-01|||20160105121022551</ns3:CorrelationUid>
<ns3:DeviceId>device-01</ns3:DeviceId>
</ns2:AsyncRequest>
</ns2:SetLightAsyncRequest>
</SOAP-ENV:Body>
</SOAP-ENV:Envelope>
<SOAP-ENV:Envelope xmlns:SOAP-ENV="http://schemas.xmlsoap.org/soap/envelope/">
<SOAP-ENV:Header />
<SOAP-ENV:Body>
<ns2:SetLightResponse xmlns:ns2="http://www.opensmartgridplatform.org/schemas/publiclighting/adhocmanagement/2014/10" xmlns:ns3="http://www.opensmartgridplatform.org/schemas/common/2014/10">
<ns2:Result>OK</ns2:Result>
</ns2:SetLightResponse>
</SOAP-ENV:Body>
</SOAP-ENV:Envelope>
OSLP SetLightRequest sent to 'device-01':
setLightRequest {
values {
on: true
}
}
OSLP SetLightResponse sent to platform:
setLightResponse {
status: OK
}