Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

V 0.4.2 Beta stove loses integrity (M1+) #75

Closed
Voidfloop opened this issue Oct 24, 2023 · 14 comments · Fixed by #84
Closed

V 0.4.2 Beta stove loses integrity (M1+) #75

Voidfloop opened this issue Oct 24, 2023 · 14 comments · Fixed by #84

Comments

@Voidfloop
Copy link

With the V 0.4.2 beta I only see one of my two stoves. Going back to the V0.4.1 beta doesn't show the phenomenon. I use two M1+ models. Have you made any progress with the problem that the stove can no longer be controlled with your integration after the stabilization phase?

@Robbe-B
Copy link
Owner

Robbe-B commented Oct 25, 2023

@Voidfloop,
I would think this is by design, are both stoves plugged in and connected ?
In v0.4.2 a change was made in order to not show disconnected devices anymore since these are uncontrollable anyway.
Can you maybe remove the integration and re-add it while both stoves are connected ?
Let me know if you still have trouble.
Kind regards,
Robbe

@Voidfloop
Copy link
Author

I just switched back to the v 0.4.2 beta and no entities are available from a Stove anymore. Back to v 0.4.1 and the Stove is back.
I tried everything else... unfortunately the result is that it must be due to v 0.4.2.

@Robbe-B
Copy link
Owner

Robbe-B commented Oct 25, 2023

Can you give me your diagnostics file from v0.4.1 ?
I'm almost certain these stoves are simply not connected to the cloud at that point.
Or Maybe they handled that differently for M1+ models 😞

@Voidfloop
Copy link
Author

@Robbe-B
Copy link
Owner

Robbe-B commented Oct 26, 2023

Hi @Voidfloop,
For the stove called "Keller" te serial number is redacted, which means it's not null or empty, so that one should show up. (Might need to reload the integration after connecting the stove to the cloud)
image
For the stove called "Wohnzimmer" the serial number seems to be null, this would mean the stove is simply not connected to the cloud when the integration is getting initialized.
image

Can you check this once more ?

Kind regards,
Robbe

@Voidfloop
Copy link
Author

Everything deleted and the v 0.4.1 beta loaded and both stoves are recognized when accessing the cloud. Here are the diagnostics:

v 0.4.1 config_entry-maestro_mcz-8a7a7d8ba44c6ad9eb0d2829c3805c16.json.txt

@Voidfloop
Copy link
Author

Everything deleted and the v 0.4.2 beta loaded and only one stove is recognized when accessing the cloud. Here are the diagnostics:
v 0.4.2 config_entry-maestro_mcz-5cdd4834f9a3b64ad866ce33567dedc0.json.txt

@Voidfloop
Copy link
Author

Both stoves are correctly registered in the cloud.
Already tried all possibilities. Reload HA, delete API and reload etcetera.

If you can get the problem under control, then we still have to look at the problem that the stoves can no longer be controlled after a while.
I will then open a new issue for this.
Thanks for your great work.

@Robbe-B
Copy link
Owner

Robbe-B commented Oct 26, 2023

@Voidfloop,
Are you running the latest and greatest firmware of these stoves ?

@Voidfloop
Copy link
Author

I don't think the firmware is up to date. Updates are reserved for the service technician. This is a disaster at MCZ. I would like to have an account for the MCZ Pro app to update My Stoves. The “basement” stove is actually 2 years younger than the “living room”.

@Robbe-B
Copy link
Owner

Robbe-B commented Oct 26, 2023

I believe you can update the firmware of your stove via the MCZ Maestro app.
Adjustments/Settings => Firmware Update => Board Firmware.

Screenshot_2023-10-26-15-22-23-06_d581526f81065272a1d0a8a34a769a6f.jpg

Screenshot_2023-10-26-15-22-27-77_d581526f81065272a1d0a8a34a769a6f.jpg

Screenshot_2023-10-26-15-22-34-60_d581526f81065272a1d0a8a34a769a6f.jpg

@Voidfloop
Copy link
Author

Unfortunately not. The firmware can only be updated via a USB stick. I've already written to MCZ, let's see what happens.

I also have to use another app. MCZ Maestro upgrade. The old app is no longer supported. The new one makes it possible to log in via the cloud. Previously this was possible without registration.

@Robbe-B
Copy link
Owner

Robbe-B commented Jan 2, 2024

@Voidfloop,
Better late then never 😄
Can you test V0.4.3-beta ?
Your feedback would be very valuable.
Kind Regards,
Robbe

@Voidfloop
Copy link
Author

Hello and thank you for your work!
You're getting closer.
The stove can be switched on and after the stabilization phase it receives the feedback “Stove switched off” again.
But this time he continues to receive feedback from the stove and I can make settings. The stove emits a beep with every input.
But one thing, the Stove is in the "Off" state and can't turn it off.
Stove_Off

MCZ EGO 8 v 0.4.3Beta.json.txt

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

Successfully merging a pull request may close this issue.

2 participants