Hardware: what it has run on, and how to add yours

README · All docs · Guides: First night · Setup · Imaging · Calibration · Focus · Science: Discovery · Results · Validation · Data · Developers: Contributing · Agents

Other mounts are wanted. It has driven one mount, a Sky-Watcher EQ3 Pro; nothing in it is meant to stay Sky-Watcher-only. Mounts says which mounts can be reached and how, in the order planned: the rest of Sky-Watcher's family through the motor board's own protocol, Celestron's NexStar hand controllers, any mount INDI drives on Linux, any ASCOM or Alpaca driver through Alpaca, and ZWO's AM mounts natively. Ask for yours, or offer to test one, with a Mount support request: the first step only reads, and nothing moves until you choose it.

Tried so far

One row for each set of equipment someone has run it on. So far all of them are the author's. Validation has the evidence behind each tick.

Mount Handset Camera and optics System What has worked Tried by
Sky-Watcher EQ3 Pro SynScan, firmware 3.35, FTDI serial lead Explorer 150P (750 mm f/5); Altair Hypercam 183C, colour (on USB 2 on 3 and 4 October 2026, on a 3 m USB 3 lead since 6 October) Ubuntu 26.04, Python 3.14 ✅ Planner, mount moves, camera, focusing (by hand and by motor), plate solving, GoTo with centring, polar alignment, imaging and stacking, under real stars the author
the same EQ3 Pro the same the same Hypercam 183C Windows 11 ⚠️ The demo, and camera frames indoors. No mount driven, no star seen the author
the same EQ3 Pro the same The 150P with a 0.9x coma corrector (675 mm f/4.5); Altair Hypercam 183M PRO TEC, mono and cooled (Altair's library, [cameras.183m], ./cameras.py); Starlight Xpress 7-position USB filter wheel (./sxwheel.py): L, R, G, B, Ha, SII, OIII Ubuntu 26.04 ✅ First night 4-5 November 2026: recognised by its profile, every frame at every readout speed, the cooler holding -5 °C with the camera kept open all session, master darks at -5 °C, all seven filter slots, focus by hand (HFR 2.0), plate solving at 1.46"/px in 0.2-0.3 s, polar alignment, and M33 in L (34 minutes of 16 s frames). ✅ 18 November 2026: the motor focuser, now a NEMA 17 on a TMC2209, focuses this train to HFR 1.67 (the night). ❌ No flats yet; the first colour picture failed (each filter's stack drifted further off; fixed, not yet rerun). The record the author
EQ5 SynScan any Linux or Windows ❔ wanted could be you
HEQ5 SynScan any Linux or Windows ❔ wanted could be you
EQ6, EQ6-R SynScan any Linux or Windows ❔ wanted could be you
any of them SynScan another INDI camera Linux ❔ wanted could be you
a mount converted with an EQStar or other EQMOD-style controller none any Linux or Windows ❔ wanted: whether it answers at all could be you

To add a row

Working or not:

  1. Run ./doctor.py --report (on Windows python doctor.py --report), or press "Write a hardware report" on the application's Doctor screen. It writes out what the computer is, what the handset says the mount is and its firmware version, and every check. It only looks: nothing is moved, and your location is left out.
  2. Paste it into a Hardware compatibility report and tick what you tried. Your GitHub name goes beside your row if you want it there.

You can stop there. If you want to go further without the mount turning, ./mount.py status reads its position and ./mount.py goto M27 --dry-run checks a move against the limits and says what it would do, without making it. For a question first ("will it work with my HEQ5?"), ask in Discussions.

A controller that is not a SynScan handset (an EQDIR lead, an Astro-Gadget EQStar, anything normally driven through EQMOD): nobody knows yet whether telescopeyoke can talk to yours, and it does not guess. Name the port and it will ask:

./doctor.py --report --probe COM7        # Linux: --probe /dev/ttyUSB0

It asks that one port what it is, first as a SynScan handset and then as a Sky-Watcher motor board (the language EQMOD speaks), at 9600 and at 115200 baud, and writes what answered into the report along with the adapter's make and USB numbers. Every question only reads; nothing is told to move. Close EQMOD first, since only one program can have the port.

Already using EQMOD or ASCOM?

Keep them. There are three ways TelescopeYoke can sit beside them, and only two of them share any equipment:

How NINA, EQMOD, PHD2 meanwhile
The companion: reads the frames your capture program saves and PHD2's guiding, and says what went wrong and why (0.4.1 and later) Run exactly as usual: it touches no device and no port
TelescopeYoke driving the mount itself, through the handset's serial lead Close EQMOD (or NINA, or the SynScan app) first: two programs cannot hold one COM port; on Windows the doctor says so when it sees ASCOM or EQMOD installed
TelescopeYoke driving your ASCOM mount, camera, focuser and wheel through Alpaca, and guiding by PHD2 (0.4.1 and later, tried on ASCOM's simulator only: Mounts) Not both at once: whether a driver lets two programs command it together is the driver's own, so check it before letting TelescopeYoke move anything NINA also has

What it adds when it drives is the part in between: targets ranked for your own horizon, a GoTo that plate-solves and centres itself, focusing by ear, and short exposures checked and stacked as they arrive.

More than one telescope

A rig is one telescope with its own settings and its own files. With two out on a good night, each runs in a window of its own:

./app.py --new-rig heq5       # its settings (rigs/heq5.toml) and "TelescopeYoke (heq5)" in the menu
./app.py --rig heq5           # open it; set it up on its Settings screen
./ty --rig heq5 mount status  # any command, for that rig
./ty rigs                     # every rig in one view: what each is and what it is imaging

Each rig keeps its own frames, pictures, calibration frames and remembered measurements under rigs/heq5/, so two nights' work never mix. The application's Rigs screen shows what every rig is doing. With no rig named everything is as before: config.toml and the folders beside it. The motion lock (MOTION_LOCKED) stops every rig at once.

What to expect of other equipment

A suggested way to describe each device when setting up a new rig, in one of four answers: ✅ proven (on this model), ⚠️ expected to work but unproven on this model, ❌ seen but not supported (it can be reported, not driven), and not found. Something showing on USB is only "seen".

Hardware Status
Sky-Watcher Explorer 150P (150 mm f/5 Newtonian) ✅ Used by the author, at 750 mm and with a 0.9x coma corrector at 675 mm
Altair Hypercam 183C (colour) ✅ Used by the author through INDI on Ubuntu and through Altair's library on Windows
Altair Hypercam 183M PRO TEC (mono, cooled) and a Starlight Xpress USB filter wheel ✅ Used by the author from 4 November 2026; see the row above for what is still to prove
Python 3.11 to 3.14 ✅ Runs on Ubuntu (no automated tests)
Windows 10 and 11 ⚠️ The demo runs with no hardware. The camera has taken frames on Windows 11, indoors. No mount has been driven from Windows, and camera and mount have not been used together there.
SynScan Wi-Fi adapter, or an EQDIR lead (no handset) ⚠️ The adapter, on the home router, has driven a real EQ3: the Dec direction check, one GoTo and home (16 November 2026, no tube on). Pointing on the sky not yet plate-solved; the EQDIR lead is untried.
EQ5, HEQ5, EQ6 with a SynScan handset ⚠️ Untested. Likely: same serial protocol.
Other INDI cameras ⚠️ Untested. Likely for mono or RGGB colour sensors: set the driver and sensor size in config.toml.
Other telescopes Set the focal length in config.toml.
ASCOM, Alpaca ⚠️ A mount through its Alpaca driver (alpaca.py): built, tried only against ASCOM's own simulator (Mounts). Focusers and filter wheels through Alpaca ([focuser] or [filterwheel] backend = "alpaca"): built, tried on the same simulator (a wheel turned by name and number, a focuser out and back to the step, its temperature); another focuser's step size against the NEMA 17's is still to be found on the sky. Guiding by PHD2 ([guider] backend = "phd2", Autoguiding): built, tried against a pretend PHD2 only. A camera through Alpaca ([camera] backend = "alpaca"): built, tried on the same simulator (frames full and 2x2 binned, mono, by ASCOM's ImageBytes or JSON, a short imaging run end to end); its cooling is left to the driver's own program. An ASCOM or EQMOD installation is noticed and left alone; see above.
Other cameras on Windows (ZWO, QHY, Player One, ...) 🧪 Through their ASCOM driver and Alpaca ([camera] backend = "alpaca"), in 0.4.1 and later: tried on ASCOM's simulator only. Otherwise Altair's own library only. On Linux, through INDI (the row above)
Other filter wheels 🧪 Through their ASCOM driver and Alpaca ([filterwheel] backend = "alpaca"), 0.4.1 and later, ASCOM's simulator only. Natively, sxwheel.py drives Starlight Xpress USB wheels only. Without a wheel, colour cameras need none
Other motor focusers 🧪 Through their ASCOM driver and Alpaca ([focuser] backend = "alpaca"), 0.4.1 and later, ASCOM's simulator only; its step size against the NEMA 17's is still to be found on the sky. Natively, focuser.py drives the home-built Arduino focuser (firmware/focuser/) only. Focusing by hand with ./focus.py (spoken and tone guidance) works with any focuser
Celestron, ZWO, iOptron and others 🗓️ Planned, in order, in Mounts; testers wanted.