# * Copyright (c) [2024] ams-OSRAM AG *
# * All rights are reserved. *
# * *
# * FOR FULL LICENSE TEXT SEE LICENSE.TXT *
# ******************************************************************************/
"""
TMF8806 ZeroMQ client and data logger example.
This example shows how to use the ZeroMQ client to control
the TMF8806 Raspberry Pi EVM and log the measurement data.
To run these examples you must have a TMF8806 Raspberry Pi EVM connected.
Or you can use a TMF8806 shield board with the matching ZeroMQ server.
You must have the zmq_client Python Package installed.
It's recommended to use a Python virtual environment.
Example (Powershell):
> python -m venv .venv-test
> ./.venv-test/Scripts/Activate.ps1
> pip install zmq_client-1.1.3.tar.gz
> python example_zmq_client.py
"""
from pathlib import Path
from time import sleep
from zmq_client.tmf8x0x_zeromq_client import ZeroMqClient
from zmq_client.tmf8x0x_zeromq_common import MeasureCommand
CMD_SERVER_ADDR = "tcp://169.254.0.2:5555"
RESULT_SERVER_ADDR = "tcp://169.254.0.2:5556"
LOG_FILE = Path(__file__).parent / "example_log_active.csv"
client = ZeroMqClient()
client.connect(cmd_addr=CMD_SERVER_ADDR,
result_addr=RESULT_SERVER_ADDR)
print("Connected to server")
try:
# As a precaution false another measurement is running
client.stop_measurement()
# configure measurement
meas_cfg = client.get_configuration()
meas_cfg.data.kIters = 4000
meas_cfg.data.data.spadSelect = 1
# configure histogram dumping
histogram_config = client.get_histogram_config()
histogram_config.summed = True
client.set_histogram_config(histogram_config)
print("Configured histogram dumping")
# Run factory calibration
print("Start factory calibration")
meas_cfg.data.command = MeasureCommand.FACTORY_CALIB
client.start_measurement(meas_cfg)
print("Finished factory calibration")
client.start_logging(LOG_FILE)
print(f"Start data logging -> {LOG_FILE.absolute()}")
meas_cfg.data.command = MeasureCommand.MEASURE
if client.start_measurement(meas_cfg):
print("Started calibrated measurement")
else:
print("Started uncalibrated measurement")
sleep(5.0)
client.stop_measurement()
client.stop_logging()
print("Stopped measurement")
finally:
client.stop_measurement()
client.disconnect()
print("Disconnect from server.")