QUALITY-SCORE.md — per-domain quality grades

Analysis Date: 2026-10-07

Overview

Quality grades per domain/layer. Scores are qualitative assessments based on test coverage, documentation, invariant enforcement, and known debt. Issue numbers in parentheses are the closed issues that moved a grade; see the Changelog at the end for when each re-derivation happened.


Domain Scores

Core Model (building_model.py)

Grade: A (unchanged)

  • Dataclass tree is well-defined with complete type hints
  • Provenance on every fact with history for revision tracking; Provenance = None no longer accepted (#402)
  • review_queue with flag_for_review() for low-confidence items; needs_review defaults fixed (#405)
  • from_dict/to_dict with generic dataclass revival
  • MODEL_VERSION 1.1 with migration; SpaceOpening.source_provenance holds up to two sheets for a merged opening (#663)
  • RoofPlane for sloped roofs (#613); matchline ids stable through export and re-import (#588)
  • No known blocking debt

Validation (validate/)

Grade: A (unchanged)

  • 49-check invariant battery documented in docs/validation.md; N_CHECKS = len(BATTERY) + len(CONSERVATION_BATTERY) is tested
  • Conservation laws block export via export_gate(), including violations introduced by the BEM transform (#230, #403, #415)
  • Post-export gbXML/IFC4 schema validation is part of the pipeline (#304, #475)
  • Defect injection tests in tests/test_validate.py (model_factory.py), parametrized for BEM checks (#344, #467)
  • Every check has error/warn/skip semantics
  • New since 2026-09-22: hvac_zone_coverage (#658), cross_level_dedup (#664)
  • envelope_closure now errors only when openings exceed the facade; it no longer caps window-to-wall ratio at 5% (#664)

Cross-Discipline Linking (link/, registration.py)

Grade: A- (was B+)

  • Two registration paths: grid (high confidence) and geometric fallback (flagged)
  • Point-in-polygon assignment with assign_points_to_spaces()
  • Facade interval matching with ambiguity detection; length-only wall matching fixed (#505)
  • Cross-level window dedup closed: merges only openings at the same along-wall position (≤5 cm) whose vertical extents meet, keeps both sheets' provenance, and a validation check catches survivors (#404, #422, #664)
  • link.py split into a package (#256)
  • Remaining gap: cross-level and per-facade links are verified on synthetic buildings only (IFC Tier 1 space attachment landed in #666/#681)

BEM Export (bem_export.py)

Grade: A- (was B+)

  • gbXML 8.01 and IFC4 export paths, both parsed with safe_xml (#272)
  • y-down → north-up flip explicit in model_from_takeoff()
  • Multi-storey export with inter-storey surface matching and shaft stacks (#632, #639)
  • OpenStudio round-trip gate in CI; RectangularGeometry-only walls fixed (#627, #628)
  • Sloped roofs with closed shells in gbXML and IFC round trip (#618, #619)
  • ASHRAE 90.1 Appendix G perimeter/core zoning with room splits and air walls (#630, #638, #648)
  • Below-grade boundary types, walk-out basements and atria (#634, #640, #641, #649, #650)
  • Remaining gap: the documented template limits in docs/bem_export.md (rectangular-room approximation, synthetic schedules, large commercial HVAC not templated)

IFC Import (ifc_import.py)

Grade: A- (was B+)

  • Tier 0 (geometry + openings without space assignment) much more complete: wall centrelines and junctions (#575, #576, #579), lining walls (#577, #597), finish slabs (#584), ceilings and plenums (#583), door operation and glazing (#573), storey fallback (#585)
  • Deterministic across runs (#586); fixture builder for mirrored placements (#587)
  • Fragment-merge and duplicate-opening parity check (#578); unattached openings counted and reported (#512)
  • Untrusted-input guards: pre-open validation and size limits (#270, #271); a broken IfcOpenShell install fails with a clear message (#407); ifcopenshell 0.9 (#528)
  • review_queue integration for low-confidence items and unclaimed wall loops (#581)
  • Tier 1 space attachment landed (#666, #681)

Geometry Simplification (geometry_simplify.py)

Grade: A- (was B)

  • Area-budgeted simplification with ≤2% drift default
  • Area-growth bugs fixed: concave-vertex handling and cost function (#329, #356, #359, #360, #472)
  • Convexity invariant tests and convex-only audit (#330, #332, #333); oblique and circulation hard-case fixtures (#502)
  • Property tests de-flaked and no longer vacuous on the #472 failure mode (#466, #476)
  • Solar-weighted roof mode (#616)
  • SimplifyResult with valid flag and area_delta_pct; validation check _check_simplify_budget
  • Tolerances documented in docs/geometry_simplify.md

HVAC Zoning (hvac_trace.py)

Grade: A- (was B+)

  • Duct tracing → terminal units → zone graphs
  • Many-to-many zone↔space relationships supported
  • Dedicated hvac_zone_coverage check: unserved terminal spaces error, unzoned floor area above 5% warns (#658)
  • Provenance on returned objects (#431); validate() name collision fixed (#319)
  • Ceiling height and plenum depth available from IFC (#583)
  • Boundary and outside-every-room diffusers resolved by duct connectivity, then nearest room within 0.5 m; ties go to review (#684)
  • Diffuser assignment uses each room's polygon_m outline when given (L-shaped and angled rooms), falling back to rect_m (#697)
  • Real-model check on the BSI Medical-Dental Clinic HVAC IFC (CC BY 4.0): room assignment 437/437 correct (#711). Detection on sheets drawn from the model, held out of training: diffuser recall 0.99–1.00, grille recall 0.65–0.87, 382 of 437 terminals placed in the correct room and 0 in a wrong room (#718, #720)
  • Remaining gap: one real model, and its sheets are drawn in matchline's own symbol style, not scanned drawings. VAV, AHU, sensor and zone grouping are still validated only on synthetic sheets, and #720 cost sensor-to-zone accuracy on synthetic seed 11 (4/5 → 2/5). Grilles read as diffusers are the main remaining false positive (#721)

Synthetic Data (synth/)

Grade: A (unchanged)

  • Deterministic generators for buildings, sheets, lighting, mechanical
  • Ground truth JSON for every synthetic sheet
  • Fixtures for bldg_3room, bldg_open_office, bldg_8room
  • Documented in docs/synth/README.md (#273)

Testing (tests/)

Grade: A (unchanged)

  • 1,744 tests with a CI test-count ratchet (EXPECTED_TEST_COUNT)
  • conftest.py with shared fixtures; model_factory.py with clean model + break_* defect injectors
  • Pipeline-level defect injection and end-to-end runs (#347, #421)
  • Property-based tests with timeouts (#269, #345); pytest-timeout (#349)
  • Detector tests run in CI (#507)
  • Golden fixtures in tests/goldens/
  • No external dataset dependencies for core tests

Code Style (ruff)

Grade: A (was A-)

  • Ruff with E, F, I, W, FA; line length 100 enforced, with inline # noqa: E501 only on geometry/XML literals (#657)
  • Ruff pinned to one version in CI and pre-commit, with grouped Renovate updates (#656)
  • Return type annotations on public functions (#444); broad except clauses removed (#445)
  • Remaining ignores (E701, E702, E741, F821) are documented pre-existing style choices

CLI (cli.py)

Grade: A (unchanged)

  • Unified matchline CLI with subcommands; the wisard-bem alias was removed in 0.2.0
  • Argument parsing with --config YAML support; --confidence-threshold range-checked (#480)
  • matchline ifc-export runs the validation gates (#478)
  • Integration tests for every subcommand (#236, #264)
  • Help text for every subcommand

Gap Summary

Domain Grade Primary Gap
Core Model A None
Validation A None
Linking A- Cross-level links verified on synthetic buildings only
BEM Export A- Template limits (synthetic schedules, large commercial HVAC not templated)
IFC Import A- Tier 1 is 2-D footprint probes; no authored-boundary cross-check (Tier 2)
Geometry A- None
HVAC A- One real model (BSI Clinic); VAV/AHU/sensor zoning validated on synthetic sheets only
Synth A None
Tests A None
Style A None
CLI A None

Changelog

  • 2026-10-07 (#719, #720): HVAC B+ → A-. Room assignment validated on the BSI Clinic HVAC model (#711). Detection carries over to sheets drawn from it after context-augmented training (#718, #720): 382 of 437 terminals land in the correct room and none in a wrong one. Also fixed a stale IFC Import section header, which still read B+ although the table and the #681 entry have it at A-.
  • 2026-10-07 (#706): Stale gap notes fixed. Linking no longer lists IFC Tier 1 attachment (merged in #666/#681). HVAC's gap summary drops "rectangular rooms" (polygon assignment since #697). BEM Export's drops it too, since spaces export as their own polygons (docs/bem_export.md). No grade changes.
  • 2026-10-06 (#681) — IFC Import B+ → A-: Tier 1 complete (opening attachment and side probes #666; host intervals, facade_unclear, adjacency_ambiguous #681). Linking gap note updated now that #666 is merged.
  • 2026-10-06 (#702) — Linking/Synthetic: opt-in north elevations in the generator (grid and no-grid, drawn as seen from the north); the no-grid registration now mirrors north/east sheets, which would otherwise have put their windows in the wrong rooms.
  • 2026-10-06 (#699) — Linking: elevation windows now link on north/east/west facades, not only south; fixed north/west facade coordinates; wall segments use room polygons when given.
  • 2026-10-07 (#697) — HVAC: diffuser-to-room assignment and the #684 boundary/nearest/tie rules measure against room polygons, so a diffuser in the notch of an L-shaped room goes to the room that fills it. Grade unchanged (synthetic-only validation remains).
  • 2026-10-07 (#693) — BEM Export: people heat gain now written (gbXML PeopleHeatGain W/person Total; IFC Pset_SpaceThermalLoad.People) from each DOE prototype row's constant occupancy activity schedule; rows with none (data center) get none.
  • 2026-10-07 (#691) — BEM Export: gbXML (single- and multi-storey) writes per-space people, lighting and equipment densities with their hourly schedules and a source note; IFC4 writes occupancy and thermal-load psets. People heat gain still not written.
  • 2026-10-06 (#685) — BEM Export: missing per-room LPD, occupant and plug-load density and schedules now default from the DOE Commercial Prototype Building Models (ASHRAE 90.1-2019, openstudio-standards v0.8.6) with doe_prototype_default provenance; drawing values are never overwritten. Grade unchanged until gbXML/IDF carry them.
  • 2026-10-06 (#684) — HVAC B → B+: diffusers on or near a wall line, or just outside every room, are assigned by duct connectivity then nearest room, and genuine ties go to review instead of the first room listed.
  • 2026-10-06 — Re-derived against issues closed since 2026-09-22 (#661). Linking B+ → A- (cross-level dedup #664, multi-provenance #663). BEM Export B+ → A- (multi-storey, OpenStudio gate, sloped roofs, Appendix G). IFC Import B → B+ (Tier 0 coverage and guards; Tier 1 still open). Geometry B → A- (simplifier area-growth fixes and tests). HVAC B- → B (hvac_zone_coverage #658). Style A- → A (E501 enforced #657, ruff pin #656). Fixed stale notes: N_CHECKS is 47, not 26; the wisard-bem alias is gone.
  • 2026-09-22 — Initial assessment.

Quality assessment: 2026-10-07