Bounded public service drain

The loopback graph-service host supports bounded removal of one service process. This is request draining, not transparent gateway failover or a mixed-version rolling-upgrade guarantee. The existing fixed cohort and server configuration still apply. See service ingress ownership.

Lifecycle

On Ctrl-C or Unix SIGTERM, the host starts drain on its HTTP and gRPC adapters before awaiting either. The adapters stop accepting new connections and reject new requests, including requests arriving on an existing connection after the admission fence. Already admitted HTTP requests and gRPC calls may finish and deliver their responses within the earlier of their original deadline and the drain deadline. Draining never resets a caller deadline or extends a session lease.

--drain-timeout-ms sets the maximum request-drain interval, from 1 through 60000 milliseconds; the default is 5000. Both listeners use the same removal phase rather than serial full grace periods. At the deadline, remaining work and response delivery are cancelled. Process scheduling and final task cleanup mean this is not a real-time exit SLA. Dropping adapter handles or shutting down the underlying gateway remains the immediate-stop fallback.

Client obligations

  • Finish active sessions before removing their owner if continued pagination is needed. Drain does not wait for a whole cursor lease or job lifecycle, persist jobs, transfer sessions, or forward an old token to another gateway.
  • A response lost during removal does not prove that a mutation was rolled back. Recover its status using the same original request identity, not a new ID or automatic arbitrary mutation replay.
  • A new gateway may open a new explicit view. It cannot relabel an old owner's cursor or silently substitute its current view.
  • Remove the endpoint from ingress selection before termination in an external deployment. There is no built-in fleet load balancer, shared session store, restored-graph activation, or automatic health-based routing in this slice.

No public administration or drain HTTP/RPC endpoint is added. Process signals and library adapter handles control termination; public APIs remain graph operations. SIGKILL cannot perform graceful draining.

Evidence and limits

The independent-process test process_drain_finishes_admitted_request_and_bounds_stalled_body uses the real graph-service, three managed node processes and another independent gateway. HTTP Expect: 100-continue establishes that a request body is already being read before SIGTERM. The test waits until both listeners reject new connections, then finishes the body and checks the complete successful read-probe response. It verifies that the other gateway remains usable. Separate cases leave a body unfinished to verify bounded termination and a shorter caller timeout remains shorter than the drain grace period. These are controlled loopback tests, not multi-host failure, network partition, all-cancellation remote resource reclamation, or write-ack delivery guarantees. Library adapter tests separately cover protocol-level request admission and cancellation behavior.