Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Consider single experiment per temperature approach #5

Open
bjartelund opened this issue Dec 15, 2019 · 2 comments
Open

Consider single experiment per temperature approach #5

bjartelund opened this issue Dec 15, 2019 · 2 comments

Comments

@bjartelund
Copy link
Owner

On the estimation errors of KM and V from time-course experiments using the Michaelis–Menten equation
Wylie Stroberg, Santiago Schnell
bioRxiv 068015; doi: https://doi.org/10.1101/068015
Now published in Biophysical Chemistry doi: 10.1016/j.bpc.2016.09.004

@bjartelund
Copy link
Owner Author

Some clear drawbacks with the approach:
You would have to run the individual experiments much longer
In my case, you reach a saturation-point where the detector is no longer capable of measuring the signal.

@bjartelund
Copy link
Owner Author

thermofit-gradient does use the absorbance to calculate concentration, could be extended to the other script as well

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment