Skip to content

the RHD2000 Interface software for intantech RHD2000 evaluation system.

License

Notifications You must be signed in to change notification settings

braindevices/RHD2kGUI

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

20 Commits
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

RHD2kGUI LW edition

the RHD20002kGUI is the Interface software for intantech RHD2000 evaluation system.

This edition enhanced the original RHD2kGUI program, by allowing Electrochemical Impedance Spectroscopy (EIS) on each individial electrode. It also automatically load settings from ~./rhd2kLWE/default.isf, which can be very convienent when run several experiments with same configuration in parallel.

Citation for this project: Chapman, C.A.R., Wang, L., Chen, H., Garrison, J., Lein, P.J., Seker, E. Advanced Functional Materials 27:1604631 (2017)

EIS scanning

Interface

If the AtuoRunEIS is checked then it starts the EIS scanning on each enabled channel when recording started.

In the Impedance panel, now we can input a list of desired frequencies. The actual frequencies used in the program are calculated and displayed below. The filename can be automatically generated based on the basefilename.

One can still start the impedance scanning manually, with the Run impedance measurement.

eisdiag

EIS data file

The data are saved as .csv The EIS csv file is like this:

Channel Number,Channel Name,Port,Enabled,Impedance Magnitude at  300.000000, 600.000000, 1000.000000, 2000.000000, 3750.000000, Hz (ohms),Impedance Phase (degrees),Series RC equivalent R (Ohms),Series RC equivalent C (Farads)
A-000,A-000,Port A,1,3.000000e+02,4.657420e+06,-72.9,1.371045e+06,9.535137e-12
A-000,A-000,Port A,1,6.000000e+02,3.075658e+06,-83.5,3.461604e+05,1.388734e-11

The first line is some comments which can be ignored. Then it comes with data rows, which have following columns:

    Channel Number,Channel Name,Port,Enabled,Hz,Impedance (ohms), Phase (degrees),Series RC equivalent R (Ohms),Series RC equivalent C (Farads)

If the scanning frequencies are: 300, 600, 1k, 2k, and 3.75k, then the loaded data is like this:

Channel Number Channel Name Port Enabled Hz Impedance (ohms) Phase (degrees) Series RC equivalent R (Ohms) Series RC equivalent C (Farads)
A-000 A-000 Port A 1 3.000000e+02 4.657420e+06 -72.9 1.371045e+06 9.535137e-12
A-000 A-000 Port A 1 6.000000e+02 3.075658e+06 -83.5 3.461604e+05 1.388734e-11
A-000 A-000 Port A 1 1.000000e+03 1.837914e+06 -87.4 8.377171e+04 2.311613e-11
A-000 A-000 Port A 1 2.000000e+03 8.718171e+05 -97.8 -1.186152e+05 4.913837e-11
A-000 A-000 Port A 1 3.750000e+03 4.466400e+05 -109.0 -1.454549e+05 1.005024e-10
A-001 A-001 Port A 1 3.000000e+02 1.435662e+06 -95.0 -1.254829e+05 2.967577e-11
A-001 A-001 Port A 1 6.000000e+02 7.301232e+05 -93.3 -4.203666e+04 5.822557e-11
A-001 A-001 Port A 1 1.000000e+03 4.378847e+05 -94.4 -3.384901e+04 9.721438e-11
A-001 A-001 Port A 1 2.000000e+03 2.117935e+05 -96.8 -2.496076e+04 2.017964e-10
A-001 A-001 Port A 1 3.750000e+03 1.053514e+05 -96.2 -1.130027e+04 4.051925e-10
A-002 A-002 Port A 1 3.000000e+02 8.124212e+06 -91.6 -2.254001e+05 5.226065e-12

load the csv data

We can use the popular python package pandas to load the data:

import pandas as pd
columns = ['Channel Number','Channel Name','Port','Enabled','Hz','Impedance (ohms)', 'Phase (degrees)','Series RC equivalent R (Ohms)','Series RC equivalent C (Farads)']
a = pd.read_csv('Serum_Media_on_EIS_160511_012211.csv', sep = ',', skiprows=[0,], names =columns, index_col=[0, 4]) # this will use the channel number and the frequency as 2-level index.

Access the loaded data is quite easy now:

>>> a.loc['A-000']
       Channel Name    Port  Enabled  Impedance (ohms)  Phase (degrees)  \
Hz                                                                        
300.0         A-000  Port A        1         4657420.0            -72.9   
600.0         A-000  Port A        1         3075658.0            -83.5   
1000.0        A-000  Port A        1         1837914.0            -87.4   
2000.0        A-000  Port A        1          871817.1            -97.8   
3750.0        A-000  Port A        1          446640.0           -109.0   

        Series RC equivalent R (Ohms)  Series RC equivalent C (Farads)  
Hz                                                                      
300.0                      1371045.00                     9.535137e-12  
600.0                       346160.40                     1.388734e-11  
1000.0                       83771.71                     2.311613e-11  
2000.0                     -118615.20                     4.913837e-11  
3750.0                     -145454.90                     1.005024e-10  

Now it can be plotted by matplotlib:

import matplotlib.pyplot as plt
 def plot_eis(a, channel):
	impedance = a.loc[channel]['Impedance (ohms)']
	phase = a.loc[channel]['Phase (degrees)']
	fig,ax=plt.subplots()
	ax2 = ax.twinx()
	_ips = ax.plot(impedance/1E6, label='impedance (Mohms)', color='C0')
	_phs = ax2.plot(phase, label='phase (degrees)', color='C1')
	lns = _ips + _phs
	labs = [l.get_label() for l in lns]
	ax.set_xscale('log', nonposx='clip')
	ax.legend(lns, labs)
	ax.grid()
	ax.set_xlabel("Freqency (Hz)")
	ax.set_ylabel(r"Z (M$\Omega$)")
	ax2.set_ylabel(r"Phase ($^\circ$)")
	plt.show()

plot_eis(a, 'A-005')

The result looks like this:

eisplot

Change the fonts

It is very common, that one find the default font does not work under their OS/Display settings. For example: beforefontchange We can see the font is too big making the text unreadable in both left and right panels. In standard edition, we have to change the system fonts to sovle this issue which is very annoying.

Now in this edition, we can simple use the font menu to change them: fontmenu

After I change left side font to 10 and right side font to 9, the text looks good: afterfontchange

Automatic load your experiment settings

It is common that one will run lots of experiments with the same settings. In standard edition, one have to keep loading the settings after reopenning the GUI. In this edition, the settings are automatically loaded from ~./rhd2kLWE/default.isf. One can save a default.isf once he/she is happy about the current settings. After that, repeating experiments with same config does not require manually loading setting file any more.

configsaveload

About

the RHD2000 Interface software for intantech RHD2000 evaluation system.

Resources

License

Stars

Watchers

Forks

Packages

No packages published

Languages