Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Add run-time check on domain of validity for self_inductance_lyle6 #9

Open
jlogan-cfs opened this issue Nov 19, 2024 · 0 comments
Open

Comments

@jlogan-cfs
Copy link
Collaborator

6th order truncated analytic solution has a finite domain of validity; can return nonphysical results for extreme coil L/D. Should add some error handling on this, and suggest an alternate solution using Neumann's method or vector potential when needed.