ARM64 Cavium Thunder - Manual Installation

This document describes how to use kubeadm to manually install Kubernetes with Contiv-VPP networking on one or more Cavium ThunderX bare metal machines provided by packet.

Preparing your hosts

Host-specific configuration

  • Packet’s Cavium Thunderx's are using bonded network configuration by default. Kubernetes with Contiv-VPP doesn't support bonding, which needs to be removed.

    WARNING: Disabling bonding will remove public connectivity from your server and you will have to use SOS to connect.

  • Configure the network according to Packet's l2 configuation instruction - section "C #3: Using eth0 with a publicly-connected VLAN and eth1 on a private VLAN".

  • Install docker.

  • Check the drivers used on the host according to 34.6.1. SR-IOV: Prerequisites and sample Application Notes.

    • In particular, verify PF and VF device capabilities
  • Check that drivers are loadable by looking for CONFIG_THUNDER_NIC in your boot config:

    $ grep CONFIG_THUNDER_NIC /boot/config-$(uname -r)
    CONFIG_THUNDER_NIC_PF=m
    CONFIG_THUNDER_NIC_VF=m
    CONFIG_THUNDER_NIC_BGX=m
    CONFIG_THUNDER_NIC_RGX=m
    

Setting up Network Adapter(s)

Setting up DPDK

DPDK setup must be set up on each node as follows:

  • Load the VFIO PCI driver:

    $ sudo modprobe vfio-pci
    
  • Verify that the VFIO PCI driver has loaded successfully:

    $ lsmod | grep vfio_pci
    vfio_pci               49152  1
    vfio_virqfd            16384  1 vfio_pci
    vfio                   40960  6 vfio_iommu_type1,vfio_pci
    

    Please note that this driver needs to be loaded upon each server bootup, so you may want to add vfio_pci into the /etc/modules file, or a file in the /etc/modules-load.d/ directory. For example, the /etc/modules file could look as follows:

    # /etc/modules: kernel modules to load at boot time.
    #
    # This file contains the names of kernel modules that should be loaded
    # at boot time, one per line. Lines beginning with "#" are ignored.
    vfio-pci
    

Determining Network Adapter PCI addresses

You need to find out the PCI address of the network interface that you want VPP to use for multi-node pod interconnect. On Debian-based distributions, you can use lshw(*):

$ sudo lshw -class network -businfo
Bus info          Device      Class      Description
====================================================
pci@0000:01:10.0              network    THUNDERX BGX (Common Ethernet Interface)
pci@0002:01:00.0              network    THUNDERX Network Interface Controller
pci@0002:01:00.1  enP2p1s0f1  network    Illegal Vendor ID
pci@0002:01:00.2  enP2p1s0f2  network    Illegal Vendor ID
pci@0002:01:00.3              network    Illegal Vendor ID
pci@0002:01:00.4              network    Illegal Vendor ID
pci@0002:01:00.5              network    Illegal Vendor ID
pci@0002:01:00.6              network    Illegal Vendor ID
pci@0002:01:00.7              network    Illegal Vendor ID
pci@0002:01:01.0              network    Illegal Vendor ID
pci@0002:01:01.1              network    Illegal Vendor ID
pci@0002:01:01.2              network    Illegal Vendor ID
pci@0002:01:01.3              network    Illegal Vendor ID
pci@0002:01:01.4              network    Illegal Vendor ID
pci@0002:01:01.5              network    Illegal Vendor ID
pci@0002:01:01.6              network    Illegal Vendor ID
pci@0002:01:01.7              network    Illegal Vendor ID
pci@0002:01:02.0              network    Illegal Vendor ID
pci@0002:01:02.1              network    Illegal Vendor ID
pci@0002:01:02.2              network    Illegal Vendor ID
pci@0002:01:02.3              network    Illegal Vendor ID
pci@0002:01:02.4              network    Illegal Vendor ID
pci@0002:01:02.5              network    Illegal Vendor ID
pci@0002:01:02.6              network    Illegal Vendor ID
pci@0002:01:02.7              network    Illegal Vendor ID
pci@0002:01:03.0              network    Illegal Vendor ID
pci@0002:00:03.0              network    THUNDERX Traffic Network Switch
pci@0006:01:00.0              network    THUNDERX Network Interface Controller
pci@0006:00:03.0              network    THUNDERX Traffic Network Switch

* On CentOS/RedHat/Fedora distributions, lshw may not be available by default, install it by yum -y install lshw

Notice that the previous command lists a lot of items. The reason is that the built-in NIC found in the Cavium ThunderX SoC family is a card with SR-IOV virtual functions (VF).

Customization on the target machine

This manual describes the successful deployment on a Ubuntu 18.04.1 LTS Kubernetes master node with 4.15.0-20-generic Linux kernel and a Ubuntu 16.04.5 LTS Kubernetes slave node with 4.10.0-38-generic Linux kernel.

  • For Ubuntu 18.04 you need to add the parameter iommu.passthrough=1 to the file /etc/default/grub.

  • To use the card built-in in the Cavium Thunderx in context of Kubernetes with Contiv-VPP network plugin there is the need to follow instructions at the DPDK pages - Linux prerequisites.

  • To mention the most important thing from DPDK setup instructions you need to setup 1GB hugepages. The allocation of hugepages should be done at boot time or as soon as possible after system boot to prevent memory from being fragmented in physical memory. Add parameters hugepagesz=1GB hugepages=16 default_hugepagesz=1GB to the file /etc/default/grub:

    The file /etc/default/grub should look like this (for Ubuntu 18.04):

    GRUB_DEFAULT=0
    #GRUB_HIDDEN_TIMEOUT=0
    GRUB_HIDDEN_TIMEOUT_QUIET=true
    GRUB_TIMEOUT=10
    GRUB_DISTRIBUTOR=Ubuntu
    GRUB_CMDLINE_LINUX="console=ttyAMA0,115200n8 biosdevname=0 net.ifnames=1 crashkernel=auto LANG=en_US.UTF-8 iommu.passthrough=1 hugepagesz=1GB hugepages=16 default_hugepagesz=1GB"
    GRUB_TERMINAL=serial
    GRUB_SERIAL_COMMAND="serial"
    

    Once the hugepage memory is reserved, to make the memory available for DPDK use, perform the following steps:

    mkdir /mnt/huge
    mount -t hugetlbfs nodev /mnt/huge_1GB pagesize=1GB
    

    or add this line to /etc/fstab file to make the mount point permanent across reboots:

    nodev /mnt/huge_1GB hugetlbfs pagesize=1GB 0 0
    

    You can check memory allocation:

    $ grep "Huge" /proc/meminfo
    AnonHugePages:         0 kB
    ShmemHugePages:        0 kB
    HugePages_Total:      16
    HugePages_Free:       16
    HugePages_Rsvd:        0
    HugePages_Surp:        0
    Hugepagesize:    1048576 kB
    

Setting up the vswitch to use Network Adapters

Finally, you need to set up the vswitch to use the network adapters:

Installing Kubernetes with Contiv-vpp CNI plugin

After the nodes have been configured, you can install the cluster using kubeadm.

(1/4) Installing Kubeadm on your hosts

For first-time installation, see Installing kubeadm. To update an existing installation, you should do a apt-get update && apt-get upgrade or yum update to get the latest version of kubeadm.

On each host with multiple NICs where the NIC that will be used for Kubernetes management traffic is not the one pointed to by the default route out of the host, a custom management network for Kubernetes must be configured.

Using Kubernetes 1.10 and above

In K8s 1.10, support for huge pages in a pod has been introduced. For now, this feature must be either disabled or memory limit must be defined for vswitch container.

This case was successfully tested: To define memory limit, append the following snippet to vswitch container in deployment yaml file:

          resources:
            limits:
              hugepages-1Gi: 8Gi
              memory: 8Gi

or set contiv.vswitch.defineMemoryLimits to true in helm values.

(2/4) Initializing your master

Before initializing the master, you may want to tear down up any previously installed K8s components. Then, proceed with master initialization as described in the kubeadm manual. Execute the following command as root:

kubeadm init --token-ttl 0 --pod-network-cidr=10.1.0.0/16

Note: kubeadm init will autodetect the network interface associated with default gateway to advertise the master's IP. If you want to use a different interface (i.e. a custom management network setup), specify the --apiserver-advertise-address=<ip-address> argument to kubeadm init. For example:

kubeadm init --token-ttl 0 --pod-network-cidr=10.1.0.0/16 --apiserver-advertise-address=192.168.56.106

Note: The CIDR specified with the flag --pod-network-cidr is used by kube-proxy, and it must include the PodSubnetCIDR from the IPAMConfig section in the Contiv-vpp config map in Contiv-vpp's deployment file (contiv-vpp.yaml). Pods in the host network namespace are a special case; they share their respective interfaces and IP addresses with the host. For proxying to work properly it is therefore required for services with backends running on the host to also include the node management IP within the --pod-network-cidr subnet. For example, with the default PodSubnetCIDR=10.1.0.0/16, the subnet 10.3.0.0/16 could be allocated for the management network and --pod-network-cidr could be defined as 10.0.0.0/8, so as to include IP addresses of all pods in all network namespaces:

kubeadm init --token-ttl 0 --pod-network-cidr=10.0.0.0/8 --apiserver-advertise-address=10.3.1.1

If Kubernetes was initialized successfully, it prints out this message:

Your Kubernetes master has initialized successfully!

After successful initialization, don't forget to set up your .kube directory as a regular user (as instructed by kubeadm):

mkdir -p $HOME/.kube
sudo cp -i /etc/kubernetes/admin.conf $HOME/.kube/config
sudo chown $(id -u):$(id -g) $HOME/.kube/config

(3/4) Installing the Contiv-VPP pod network

Install the Contiv-VPP network for your cluster as follows:

  • If you do not use the STN feature, install Contiv-vpp as follows:

    kubectl apply -f https://raw.githubusercontent.com/contiv/vpp/master/k8s/contiv-vpp-arm64.yaml
    
  • If you use the STN feature, download the contiv-vpp.yaml file:

    wget https://raw.githubusercontent.com/contiv/vpp/master/k8s/contiv-vpp-arm64.yaml
    

    Then edit the STN configuration as described here. Finally, create the Contiv-vpp deployment from the edited file:

    kubectl apply -f ./contiv-vpp-arm64.yaml
    

Beware contiv-etcd data is persisted in /var/etcd by default. It has to be cleaned up manually after kubeadm reset. Otherwise outdated data will be loaded by a subsequent deployment.

You can also generate random subfolder, alternatively:

curl --silent https://raw.githubusercontent.com/contiv/vpp/master/k8s/contiv-vpp-arm64.yaml | sed "s/\/var\/etcd\/contiv-data/\/var\/etcd\/contiv-data\/$RANDOM/g" | kubectl apply -f -

Deployment Verification

After some time, all contiv containers should enter the running state:

$ kubectl get pods -n kube-system -o wide | grep contiv
NAME                                   READY     STATUS    RESTARTS   AGE       IP              NODE
contiv-etcd-0                          1/1       Running   0          1d        147.75.98.202   cvpp
contiv-ksr-4pw9s                       1/1       Running   0          1d        147.75.98.202   cvpp
contiv-vswitch-ptx7n                   1/1       Running   0          1d        147.75.98.202   cvpp

In particular, make sure that the Contiv-VPP pod IP addresses are the same as the IP address specified in the --apiserver-advertise-address=<ip-address> argument to kubeadm init.

Verify that the VPP successfully grabbed the network interface specified in the VPP startup config (VirtualFunctionEthernet1/0/2 in our case):

$ docker exec -it  `docker ps | grep "\/usr\/bin\/supervisor" | cut --delimiter=" " --fields=1` /usr/bin/vppctl
    _______    _        _   _____  ___
 __/ __/ _ \  (_)__    | | / / _ \/ _ \
 _/ _// // / / / _ \   | |/ / ___/ ___/
 /_/ /____(_)_/\___/   |___/_/  /_/

vpp# show interface
              Name               Idx    State  MTU (L3/IP4/IP6/MPLS)     Counter          Count
VirtualFunctionEthernet1/0/2      1      up          9000/0/0/0     rx packets                  1031
                                                                    rx bytes                   66879
                                                                    tx packets                  1043
                                                                    tx bytes                   58887
                                                                    drops                        498
                                                                    ip4                           52
                                                                    tx-error                       1
local0                            0     down          0/0/0/0
loop0                             3      up          9000/0/0/0     rx packets                    47
                                                                    rx bytes                    4641
                                                                    tx packets                   118
                                                                    tx bytes                   11226
                                                                    drops                         16
                                                                    ip4                           47
tap0                              2      up          1500/0/0/0     rx packets                291928
                                                                    rx bytes               106499985
                                                                    tx packets                214364
                                                                    tx bytes                17420543
                                                                    drops                        780
                                                                    ip4                       291148
                                                                    ip6                           39
tap1                              5      up          1500/0/0/0     rx packets                106880
                                                                    rx bytes                 8700437
                                                                    tx packets                146750
                                                                    tx bytes                53313139
                                                                    drops                         60
                                                                    ip4                       106841
                                                                    ip6                           39
tap2                              6      up          1500/0/0/0     rx packets                106877
                                                                    rx bytes                 8700012
                                                                    tx packets                144447
                                                                    tx bytes                53157700
                                                                    drops                         51
                                                                    ip4                       106839
                                                                    ip6                           38
vpp# show interface addr
VirtualFunctionEthernet1/0/2 (up):
  L3 192.168.16.1/24
local0 (dn):
loop0 (up):
  L2 bridge bd-id 2 idx 2 shg 1 bvi
  L3 192.168.30.1/24
tap0 (up):
  L3 172.30.1.1/24
tap1 (up):
  L3 10.2.1.2/32
tap2 (up):
  L3 10.2.1.3/32
vpp#

You should also see the interfaces to coredns (tap1 and tap2) and to the node's IP stack (tap0).

Master Isolation (Optional)

By default, your cluster will not schedule pods on the master for security reasons. If you want to be able to schedule pods on the master, e.g. for a single-machine Kubernetes cluster for development, run:

kubectl taint nodes --all node-role.kubernetes.io/master-

More details about installing the pod network can be found in the kubeadm manual.

(4/4) Joining your nodes

To add a new node to your cluster, run as root the command that was output by kubeadm init. For example:

kubeadm join --token <token> <master-ip>:<master-port> --discovery-token-ca-cert-hash sha256:<hash>

After starting kubernetes you can look at how a join command looks like:

$ sudo kubeadm token create --print-join-command
kubeadm join 147.75.98.202:6443 --token v7qx7g.dkiy12lxt6sd534q --discovery-token-ca-cert-hash sha256:73e924e696ddb0a7016d7e70053b46664ab5361b3b8e6099cb55dadaa202fd67

More details can be found in the kubeadm manual.

Deployment Verification

After some time, all contiv containers should enter the running state:

$ kubectl get pods -n kube-system -o wide
NAME                                   READY     STATUS    RESTARTS   AGE       IP              NODE
contiv-etcd-0                          1/1       Running   0          1d        147.75.98.202   cvpp
contiv-ksr-4pw9s                       1/1       Running   0          1d        147.75.98.202   cvpp
contiv-vswitch-ptx7n                   1/1       Running   0          1d        147.75.98.202   cvpp
contiv-vswitch-rvh8p                   1/1       Running   0          14s       147.75.72.194   cvpp-slave2
coredns-78fcdf6894-lvcj4               1/1       Running   0          1d        10.1.1.2        cvpp
coredns-78fcdf6894-tsxhl               1/1       Running   0          1d        10.1.1.3        cvpp
etcd-cvpp                              1/1       Running   0          1d        147.75.98.202   cvpp
kube-apiserver-cvpp                    1/1       Running   0          1d        147.75.98.202   cvpp
kube-controller-manager-cvpp           1/1       Running   0          1d        147.75.98.202   cvpp
kube-proxy-8dfjz                       1/1       Running   0          14s       147.75.72.194   cvpp-slave2
kube-proxy-9p6rq                       1/1       Running   0          1d        147.75.98.202   cvpp
kube-scheduler-cvp                     1/1       Running   0          1d        147.75.98.202   cvpp

In particular, verify that a vswitch pod and a kube-proxy pod is running on each joined node, as shown above.

On each joined node, verify that the VPP successfully grabbed the network interface specified in the VPP startup config (VirtualFunctionEthernet1/0/2 in our case):

$ docker exec -it  `docker ps | grep "\/usr\/bin\/supervisor" | cut --delimiter=" " --fields=1` /usr/bin/vppctl
...
vpp# show interface
              Name               Idx    State  MTU (L3/IP4/IP6/MPLS)     Counter          Count
VirtualFunctionEthernet1/0/2      1      up          9000/0/0/0     rx packets                  1031
...

You can also ping coredns from VPP on a joined node to verify node-to-node connectivity. For example:

vpp# ping 10.1.1.2
64 bytes from 10.1.1.2: icmp_seq=2 ttl=63 time=.9912 ms
64 bytes from 10.1.1.2: icmp_seq=3 ttl=63 time=.7172 ms
64 bytes from 10.1.1.2: icmp_seq=4 ttl=63 time=.7189 ms
64 bytes from 10.1.1.2: icmp_seq=5 ttl=63 time=.8852 ms

Statistics: 5 sent, 4 received, 20% packet loss
vpp#

Deploying example applications

Simple deployment

You can go ahead and create a simple deployment:

$ kubectl run nginx --image=nginx --replicas=2

Use kubectl describe pod to get the IP address of a pod, e.g.:

$ kubectl describe pod nginx | grep IP

You should see two ip addresses, for example:

IP:                 10.1.1.7
IP:                 10.1.1.8

Note: You can find these IP addresses also issuing command kubectl get pods -o wide

You can check the pods' connectivity in one of the following ways:

  • Connect to the VPP debug CLI and ping any pod:
  sudo vppctl
  vpp# ping 10.1.1.7
  • Start busybox and ping any pod:
  kubectl run busybox --rm -ti --image=busybox /bin/sh
  If you don't see a command prompt, try pressing enter.
  / #
  / # ping 10.1.1.7

  • You should be able to ping any pod from the host:
  ping 10.1.1.7

Deploying pods on different nodes

To enable pod deployment on the master, untaint the master first:

kubectl taint nodes --all node-role.kubernetes.io/master-

In order to verify inter-node pod connectivity, we need to tell Kubernetes to deploy one pod on the master node and one POD on the worker. For this, we can use node selectors.

In your deployment YAMLs, add the nodeSelector sections that refer to preferred node hostnames, e.g.:

  nodeSelector:
    kubernetes.io/hostname: vm5

Example of whole JSONs:

apiVersion: v1
kind: Pod
metadata:
  name: nginx1
spec:
  nodeSelector:
    kubernetes.io/hostname: vm5
  containers:
    - name: nginx
      image: nginx
apiVersion: v1
kind: Pod
metadata:
  name: nginx2
spec:
  nodeSelector:
    kubernetes.io/hostname: vm6
  containers:
    - name: nginx
      image: nginx

After deploying the JSONs, verify they were deployed on different hosts:

$ kubectl get pods -o wide
NAME      READY     STATUS    RESTARTS   AGE       IP           NODE
nginx1    1/1       Running   0          13m       10.1.36.2    vm5
nginx2    1/1       Running   0          13m       10.1.219.3   vm6

Now you can verify the connectivity to both nginx PODs from a busybox POD:

kubectl run busybox --rm -it --image=busybox /bin/sh

/ # wget 10.1.36.2
Connecting to 10.1.36.2 (10.1.36.2:80)
index.html           100% |*******************************************************************************************************************************************************************|   612   0:00:00 ETA

/ # rm index.html

/ # wget 10.1.219.3
Connecting to 10.1.219.3 (10.1.219.3:80)
index.html           100% |*******************************************************************************************************************************************************************|   612   0:00:00 ETA

Or try redeployment like this:

$ kubectl scale --current-replicas=2 --replicas=4 deployment/nginx
deployment.extensions/nginx scaled
$ kubectl get pods -o wide
NAME                     READY     STATUS    RESTARTS   AGE       IP         NODE
nginx-64f497f8fd-2cjfv   1/1       Running   0          14s       10.1.2.2   cvpp-slave2
nginx-64f497f8fd-gmk55   1/1       Running   0          34m       10.1.1.7   cvpp
nginx-64f497f8fd-j5q4b   1/1       Running   0          34m       10.1.1.8   cvpp
nginx-64f497f8fd-sv6bh   1/1       Running   0          14s       10.1.2.3   cvpp-slave2

Again you can try to verify connection by starting busybox and trying to access the webpages in deployed pods.

Note: To delete the deployment, issue the commnad kubectl delete deployment/nginx

Uninstalling Contiv-VPP

To uninstall the network plugin itself, use kubectl:

kubectl delete -f https://raw.githubusercontent.com/contiv/vpp/master/k8s/contiv-vpp-arm64.yaml

Tearing down Kubernetes

  • First, drain the node and make sure that the node is empty before shutting it down:
  kubectl drain <node name> --delete-local-data --force --ignore-daemonsets
  kubectl delete node <node name>
  • Next, on the node being removed, reset all kubeadm installed state:
  rm -rf $HOME/.kube
  sudo su
  kubeadm reset
  • If you added environment variable definitions into /etc/systemd/system/kubelet.service.d/10-kubeadm.conf (e.g. in Step 1/4), clean them up now.

Troubleshooting

Some of the issues that can occur during the installation are:

  • Forgetting to create and initialize the .kube directory in your home directory (As instructed by kubeadm init --token-ttl 0). This can manifest itself as the following error:
    W1017 09:25:43.403159    2233 factory_object_mapping.go:423] Failed to download OpenAPI (Get https://192.168.209.128:6443/swagger-2.0.0.pb-v1: x509: certificate signed by unknown authority (possibly because of "crypto/rsa: verification error" while trying to verify candidate authority certificate "kubernetes")), falling back to swagger
    Unable to connect to the server: x509: certificate signed by unknown authority (possibly because of "crypto/rsa: verification error" while trying to verify candidate authority certificate "kubernetes")
    
  • Previous installation lingering on the file system. 'kubeadm init --token-ttl 0 fails to initialize kubelet with one or more of the following error messages:
    ...
    [kubelet-check] It seems like the kubelet isn't running or healthy.
    [kubelet-check] The HTTP call equal to 'curl -sSL http://localhost:10255/healthz' failed with error: Get http://localhost:10255/healthz: dial tcp [::1]:10255: getsockopt: connection refused.
    ...
    

If you run into any of the above issues, try to clean up and reinstall as root:

sudo su
rm -rf $HOME/.kube
kubeadm reset
kubeadm init --token-ttl 0
rm -rf /var/etcd/contiv-data