You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
IRL AC unit did not respond to half degree C commands for TCL 112 Protocol. Compared to IR code from remote and found HalfDegree bit in wrong position. Corrected on local copy of code and verified desired functionality on IRL unit.
Byte 12 of TCL protocol should be as follows
uint8_t :2;
uint8_t HalfDegree :1;
uint8_t SwingH :1;
uint8_t :3;
uint8_t isTcl :1;
The text was updated successfully, but these errors were encountered:
Make and Model is a "Denali Aire", "1DAC10K" which seems to be just another reseller of 3rd party built equipment. The remote is branded "Denali Aire" but without a model number. Opening the remote revels a PCB with the following details
I suppose its possible this remote / unit uses a slightly modified protocol, but literally everything else matches and I've run in to no other issues (on things it supports anyways - this unit doesn't have heat for example)
Version 2.8.5
Describe the bug
IRL AC unit did not respond to half degree C commands for TCL 112 Protocol. Compared to IR code from remote and found HalfDegree bit in wrong position. Corrected on local copy of code and verified desired functionality on IRL unit.
Byte 12 of TCL protocol should be as follows
uint8_t :2;
uint8_t HalfDegree :1;
uint8_t SwingH :1;
uint8_t :3;
uint8_t isTcl :1;
The text was updated successfully, but these errors were encountered: