doc/src/records/dhwsys.md

Lines changed: 11 additions & 7 deletions
Original file line numberDiff line numberDiff line change
@@ -35,6 +35,10 @@ Optional name of system; give after the word “DHWSYS” if desired.
3535

3636
Name of a DHWSYS that serves the same loads as this DHWSYS, allowing representation of multiple water heating systems within a unit. If given, wsUse and wsDayUse are not allowed, hot water requirements are derived from the referenced DHWSYS. wsCentralDHWSYS and wsLoadShareDHWSYS cannot both be given.
3737

38+
Loads are shared by assigning DHWUSE events sequentially to all DHWSYSs in a group. This algorithm approximately divides the load by the number of DHWSYSs in the group.
39+
40+
For example, two DHWSYSs should be defined to model two water heating systems serving a load represented by wsDayUse DayUseTyp. Each DHWSYS should include DHWHEATER(s) and other components as needed. DHWSYS Sys1 should specify wsDayUse=DayUseTyp and DHWSYS Sys2 should have wsLoadShareDHWSYS=Sys1 in place of wsDayUse.
41+
3842
**Units** **Legal Range** **Default** **Required** **Variability**
3943
----------- ------------------- ---------------------- -------------- -----------------
4044
*name of a DHWSYS* No shared loads No constant
@@ -110,39 +114,39 @@ Specifies electrical parasitic power to represent recirculation pumps or other s
110114

111115
Specifies the standard distribution loss multiplier. See App B Eqn 4. To duplicate CEC 2016 methods, this value should be set according to the value derived with App B Eqn 5.
112116

113-
**Units** **Legal Range** **Default** **Required** **Variability**
117+
**Units** **Legal Range** **Default** **Required** **Variability**
114118
----------- ----------------- ------------- -------------- -----------------
115-
$>$ 0 1 No constant
119+
$>$ 0 1 No constant
116120

117121
**wsDSM=*float***
118122

119123
Distribution system multiplier. See RACM App B Eqn 4. To duplicate CEC 2016 methods, wsDSM should be set to the appropriate value from App B Table B-2. Note the NCF (non-compliance factor) included in App B Eqn 4 is *not* a CSE input and thus must be applied externally to wsDSM.
120124

121-
**Units** **Legal Range** **Default** **Required** **Variability**
125+
**Units** **Legal Range** **Default** **Required** **Variability**
122126
----------- ----------------- ------------- -------------- -----------------
123-
$>$ 0 1 No constant
127+
$>$ 0 1 No constant
124128

125129
**wsWF=*float***
126130

127131
Waste factor. See RACM App B Eqn 1. wsWF is applied to hot water draws. The default value (1) reflects the inclusion of waste in draw amounts. App B specifies wsWF=0.9 when the system has a within-unit pumped loop that reduces waste due to immediate availability of hot water at fixtures.
128132

129-
**Units** **Legal Range** **Default** **Required** **Variability**
133+
**Units** **Legal Range** **Default** **Required** **Variability**
130134
----------- ----------------- ------------- -------------- -----------------
131135
$>$ 0 1 No hourly
132136

133137
**wsSSF=*float***
134138

135139
Specifies the solar savings fraction.
136140

137-
**Units** **Legal Range** **Default** **Required** **Variability**
141+
**Units** **Legal Range** **Default** **Required** **Variability**
138142
----------- ----------------- ------------- -------------- -----------------
139143
$\ge$ 0 0 No hourly
140144

141145
**wsElecMtr=*mtrName***
142146

143147
Name of METER object, if any, to which DHWSYS electrical energy use is recorded (under end use DHW). In addition, wsElecMtr provides the default whElectMtr selection for all DHWHEATERs and DHWPUMPs in this DHWSYS.
144148

145-
**Units** **Legal Range** **Default** **Required** **Variability**
149+
**Units** **Legal Range** **Default** **Required** **Variability**
146150
----------- ------------------- ---------------- -------------- -----------------
147151
*name of a METER* *not recorded* No constant
148152

src/DHWCalc.cpp

Lines changed: 83 additions & 62 deletions
Original file line numberDiff line numberDiff line change
@@ -266,7 +266,7 @@ struct DWHRUSE // info about 1 (shower) draw that could have DWHR
266266
DWHRUSE() : wdw_iFx( -1), wdw_coldCnx( 0), wdw_vol( 0.f), wdw_volHR( 0.f), wdw_temp( 0.f)
267267
{}
268268
DWHRUSE( int iFx, int coldCnx, float vol, float volHR, float temp)
269-
: wdw_coldCnx( coldCnx), wdw_vol( vol), wdw_volHR( volHR), wdw_temp( temp)
269+
: wdw_iFx( iFx), wdw_coldCnx( coldCnx), wdw_vol( vol), wdw_volHR( volHR), wdw_temp( temp)
270270
{}
271271
~DWHRUSE() {}
272272

@@ -1009,7 +1009,7 @@ void DHWSYS::ws_InitTicks( // initialize tick data for hour
10091009
ws_iTkNDWHR = -1;
10101010
} // DHWSYS::ws_InitTicks
10111011
//----------------------------------------------------------------------------
1012-
RC DHWSYS::ws_DoHourDWHR() // current hour DHWHEATREC modeling
1012+
RC DHWSYS::ws_DoHourDWHR() // current hour DHWHEATREC modeling (all DHWHEATRECs)
10131013
{
10141014
RC rc = RCOK;
10151015

@@ -1024,62 +1024,86 @@ RC DHWSYS::ws_DoHourDWHR() // current hour DHWHEATREC modeling
10241024
// ws_qDWHR = 0.f; // total heat recovered by all DHWHEATREC devices, Btu
10251025
// ws_whUseNoHR = 0.; // check value: hour total hot water use w/o HR, gal
10261026
// init'd by caller
1027-
double qRWHSum = 0.;
1027+
double qRWHSum = 0.; // hour total recovered heat to WH inlet, Btu
1028+
int multiDraw = 0;
10281029
// int nTk = Top.tp_NHrTicks();
10291030
for (int iTk=ws_iTk0DWHR; iTk < ws_iTkNDWHR; iTk++)
10301031
{ DHWTICK& tk = ws_ticks[ iTk]; // DHWSYS tick info
10311032
if (tk.wtk_nHRDraws == 0)
10321033
continue; // no DHWHEATREC draws in this tick
1033-
float vOther // non-DHWHEATREC draws that contribute to each
1034+
if (tk.wtk_nHRDraws > 1)
1035+
multiDraw++;
1036+
float whUseOther = tk.wtk_whUse;
1037+
float vHotOther // non-DHWHEATREC draws that contribute to each
10341038
// feedWH-DHWHEATREC potable-side vol
1035-
= tk.wtk_whUse / max(ws_wrFeedWHCount, 1);
1039+
= whUseOther / max(ws_wrFeedWHCount, 1);
1040+
#if defined( _DEBUG)
1041+
int nReDo = 0; // debugging aid, see below
1042+
reDo:
1043+
#endif
10361044
float whUse = 0.f; // hot water use, this tick / all DHWHEATREC draws
10371045
float fxUseMix = 0.f; // mixed water use
10381046
float qR = 0.f; // tick heat recovered
10391047
float qRWH = 0.f; // tick heat recovered to WH feed
1048+
float whUseNoHR = 0.f; // tick hot water use w/o HR
10401049
DHWHEATREC* pWR;
10411050
RLUPC(WrR, pWR, pWR->ownTi == ss)
10421051
{ DHWHRTICK& wrtk = pWR->wr_ticks[iTk]; // DHWHEATREC tick info
10431052
if (wrtk.wrtk_draws.size() > 0)
10441053
whUse += pWR->wr_CalcTick( this,
10451054
wrtk, // tick info for *pWR
1046-
vOther, // total non-HR hot water use, gal
1047-
ws_whUseNoHR, fxUseMix, qR, qRWH); // results accum'd
1055+
vHotOther, // total non-HR hot water use, gal
1056+
whUseNoHR, fxUseMix, qR, qRWH); // results accum'd
10481057
}
1049-
ws_AccumUseTick( // accum to ws_tick, ws_whUse, and ws_fxMixUse
1050-
C_DHWEUCH_SHOWER, iTk, fxUseMix, whUse);
1058+
#if defined( _DEBUG)
1059+
if (!nReDo)
1060+
#endif
1061+
ws_AccumUseTick( // accum to ws_tick, ws_whUse, and ws_fxMixUse
1062+
C_DHWEUCH_SHOWER, iTk, fxUseMix, whUse);
1063+
1064+
// water heater inlet temp
10511065
float tO = ws_tInlet;
10521066
if (tk.wtk_whUse > 0.)
10531067
tO += qRWH / (waterRhoCp * tk.wtk_whUse);
1054-
#if defined( _DEBUG)
1055-
else if (qRWH > 0.f)
1056-
printf("\nInconsistency: wtk_whUse=%0.3f qRWHWt=%0.3f",
1057-
tk.wtk_whUse, qRWH);
1058-
#endif
10591068
tk.wtk_tInletX = ws_AdjustTInletForSSF(tO);
1060-
qRWHSum += qRWH;
1061-
ws_qDWHR += qR; // accum to hour total heat recovered
1062-
} // end tick
10631069

1064-
#if 0 && defined( _DEBUG)
1065-
if (frDiff( float( whUseTot), ws_whUse.total, .001f) > .001f)
1066-
printf( "\nMismatch!");
1070+
#if defined( _DEBUG)
1071+
// tick energy balance
1072+
float qXNoHR = (whUseNoHR+whUseOther) * waterRhoCp * (ws_tUse - ws_tInlet);
1073+
float qX = tk.wtk_whUse * waterRhoCp * (ws_tUse - tO);
1074+
float qXHR = qX + qR;
1075+
if (frDiff(qXHR, qXNoHR, 1.f) > .001f)
1076+
{
1077+
printf("\nDHWSYS '%s': ws_DoHourDWHR tick balance error (md=%d)", name, multiDraw);
1078+
if (nReDo++ < 2)
1079+
goto reDo; // repeat calc (debugging aid)
1080+
}
10671081
#endif
1082+
ws_qDWHR += qR; // hour total heat recovered
1083+
qRWHSum += qRWH; // hour total heat to WH inlet
1084+
ws_whUseNoHR += whUseNoHR; // hour total WH use w/o HR
1085+
1086+
} // end tick
10681087

1069-
// calc hour average adjusted inlet and hot water temps
1070-
float tInletXNoSSF = ws_tInlet;
1088+
// hour average adjusted inlet and hot water temps
1089+
float tInletXNoSSF;
10711090
if (qRWHSum > 0.)
1072-
{ tInletXNoSSF = ws_tInlet + qRWHSum / (waterRhoCp * ws_whUse.total);
1073-
ws_tInletX = ws_AdjustTInletForSSF( tInletXNoSSF);
1091+
{
1092+
tInletXNoSSF = ws_tInlet + qRWHSum / (waterRhoCp * ws_whUse.total);
1093+
ws_tInletX = ws_AdjustTInletForSSF(tInletXNoSSF);
10741094
}
1095+
else
1096+
tInletXNoSSF = ws_tInlet;
10751097

10761098
#if defined( _DEBUG)
1077-
float qXNoHR = ws_whUseNoHR * waterRhoCp * (ws_tUse - ws_tInlet);
1099+
// hour energy balance
1100+
float qXNoHR = ws_whUseNoHR * waterRhoCp * (ws_tUse - ws_tInlet);
10781101
float qX = ws_whUse.total * waterRhoCp * (ws_tUse - tInletXNoSSF);
1079-
if (frDiff(qX+ws_qDWHR, qXNoHR, 1.f) > .001f)
1080-
printf( "\nDHWSYS '%s': ws_DoHourDWHR balance error", name);
1102+
float qXHR = qX + ws_qDWHR;
1103+
if (frDiff(qXHR, qXNoHR, 1.f) > .001f)
1104+
printf("\nDHWSYS '%s': ws_DoHourDWHR balance error (md=%d)", name, multiDraw);
10811105
#endif
1082-
1106+
10831107
return rc;
10841108
} // DHWSYS::ws_DoHourDWHR
10851109
//----------------------------------------------------------------------------
@@ -2702,7 +2726,7 @@ RC DHWHEATREC::wr_SetFXConnections(
27022726
float DHWHEATREC::wr_CalcTick( // calculate performance for 1 tick
27032727
DHWSYS* pWS, // parent DHWSYS
27042728
DHWHRTICK& wrtk, // current tick info for this DHWHEATREC
2705-
float vOther, // hot water draws for other fixtures, gal
2729+
float vHotOther, // hot water draws for other fixtures, gal
27062730
// included in potable flow if feedsWH
27072731
float& whUseNoHR, // returned updated: hot water use w/o heat recovery, gal
27082732
// used re energy balance check
@@ -2711,40 +2735,26 @@ float DHWHEATREC::wr_CalcTick( // calculate performance for 1 tick
27112735
float& qRWH) // returned updated: tick recovered heat added to WH inlet water, Btu
27122736

27132737
// returns hot water use for served fixtures, gal
2714-
// (not including vOther)
2738+
// (not including vHotOther)
27152739
{
27162740
int nD = wrtk.wrtk_draws.size();
27172741
if (nD == 0)
27182742
return 0.f; // no draws, no effect
27192743

2720-
#if 0 && defined( _DEBUG)
2721-
// if (Top.jDay == 91 && Top.iHr == 20)
2722-
// printf(" Hit\n");
2723-
static int nDMulti = 0;
2724-
if (nD > 1)
2725-
{
2726-
if (nDMulti++ == 0)
2727-
printf("\nMultiple draws: jDay=%d iH=%d",
2728-
Top.jDay, Top.iHr);
2729-
}
2730-
else
2731-
nDMulti = 0;
2732-
#endif
2733-
27342744
// tick constants
27352745
float tpI = pWS->ws_tInlet; // mains temp
27362746
float tHotFX = pWS->ws_tUse; // hot water temp at fixture
27372747

27382748
float vd = 0.f; // total mixed use at all fixture(s), all draws, gal
27392749
// = drain volume
27402750
float tdI = 0.f; // average drain-side entering temp, F
2741-
float vMixHR = 0.f; // total mixed use at fixtures with cold side
2751+
float vMixFXHR = 0.f; // total mixed use at fixtures with cold side
27422752
// connection to DHWHEATREC, gal
27432753
float vHotFX0= 0.f; // hot water req'd for fixtures that use
27442754
// mains water for mixing, gal
27452755

27462756
// re parallel potable-side DHWHEATRECs
2747-
// caller allocates vOther equally to all feedsWH-DHWHEATREC(s) in DHWSYS
2757+
// caller allocates vHotOther equally to all feedsWH-DHWHEATREC(s) in DHWSYS
27482758
// >> DHWHEATER inlet flow for other draws assumed to flow equally via parallel paths
27492759
// this-DHWHEATREC fixture flows are assigned to this-DHWHEATREC potable flow
27502760
// >> this-DHWHEATER's fixtures DHWHEATER and tempering flows do NOT
@@ -2774,7 +2784,7 @@ float DHWHEATREC::wr_CalcTick( // calculate performance for 1 tick
27742784
else
27752785
// fixture cold comes from DHWHEATREC
27762786
// accum mixed vol, compute vHotFX below
2777-
vMixHR += hru.wdw_vol;
2787+
vMixFXHR += hru.wdw_vol;
27782788
}
27792789
fxUseMix += vd; // accum to caller's total
27802790

@@ -2783,16 +2793,16 @@ float DHWHEATREC::wr_CalcTick( // calculate performance for 1 tick
27832793
tdI = bracket(tpI, tdI/max( vd, .0001f), tHotFX);
27842794

27852795

2786-
float vp; // potable-side flow, gal
2787-
float tpO = 0.f;// potable-side outlet temp, F
2788-
float vHotFX; // fixture hot vol, gal
2796+
float vp = 0.f; // potable-side flow, gal
2797+
float tpO = 0.f; // potable-side outlet temp, F
2798+
float vHotFX = 0.f; // fixture hot vol, gal
27892799

2790-
if (wr_FeedsFX())
2800+
if (vMixFXHR > 0.f) // if any current draw feeds a fixture
27912801
{
27922802
// DHWHEATREC feeds fixture(s) and possibly WH
27932803
vp = wr_FeedsWH() // potable volume
2794-
? vMixHR + vHotFX0 + vOther // feeds both
2795-
: vMixHR / 2.f; // fixture only: 1st guess
2804+
? vMixFXHR + vHotFX0 + vHotOther // feeds both
2805+
: vMixFXHR / 2.f; // fixture only: 1st guess
27962806
int iL;
27972807
for (iL = 0; iL<10; iL++)
27982808
{ // cold water temp at wdw_coldCnx fixture(s)
@@ -2808,7 +2818,7 @@ float DHWHEATREC::wr_CalcTick( // calculate performance for 1 tick
28082818
vHotFX += hru.wdw_vol * DHWMixF(hru.wdw_temp, tHotFX, tpO);
28092819
}
28102820
if (!wr_FeedsWH())
2811-
vp = vMixHR - vHotFX; // cold side flow
2821+
vp = vMixFXHR - vHotFX;
28122822

28132823
#if 0 && defined( _DEBUG)
28142824
if (iL > 7)
@@ -2818,20 +2828,31 @@ float DHWHEATREC::wr_CalcTick( // calculate performance for 1 tick
28182828
break;
28192829
wr_EffAdjusted(vp, tpI, vd, tdI); // update efficiency
28202830
}
2831+
vHotFX += vHotFX0; // total fixture hot water
28212832
}
28222833
else
2823-
{ // DWHR feeds WH only -- flows known
2824-
vHotFX = vHotFX0;
2825-
vp = vHotFX + vOther;
2826-
wr_EffAdjusted(vp, tpI, vd, tdI); // derive wr_eff
2827-
tpO = wr_HX(vp, tpI, vd, tdI);
2834+
{ // no current fixture draw uses tempered cold-side water
2835+
// all flows known
2836+
vHotFX = vHotFX0; // hot water needed
2837+
if (wr_FeedsWH())
2838+
{ // potable side feeds water heater
2839+
// recovered heat boosts tInlet
2840+
vp = vHotFX + vHotOther;
2841+
wr_EffAdjusted(vp, tpI, vd, tdI); // derive wr_eff
2842+
tpO = wr_HX(vp, tpI, vd, tdI);
2843+
}
2844+
else
2845+
{ // does not feed WH
2846+
// no heat recovered
2847+
vp = 0.f; // no potable-side flow
2848+
tpO = tpI; // outlet temp = inlet temp (insurance)
2849+
}
28282850
}
28292851

28302852
float qR1 = vp * waterRhoCp * (tpO - tpI); // recovered heat
28312853
qR += qR1;
2832-
qRWH += wr_FeedsWH() && vp > 0.f // recovered heat to WH
2833-
? qR1 * (vHotFX + vOther) / vp
2834-
: 0.f;
2854+
if (wr_FeedsWH() && vp > 0.f)
2855+
qRWH += qR1 * (vHotFX + vHotOther) / vp; // recovered heat to WH
28352856
return vHotFX;
28362857

28372858
} // DHWHEATREC::wr_CalcTick

src/WFPAK.CPP

Lines changed: 2 additions & 2 deletions
Original file line numberDiff line numberDiff line change
@@ -2511,9 +2511,9 @@ x printf( "mismatch\n");
25112511
{
25122512
const char* fName = "tSky.csv";
25132513
pF = fopen(fName, "wt");
2514-
fprintf(pF, "mon,day,hr,tSky_CSE,tSky_IR\n");
2514+
fprintf(pF, "yr,mon,day,hr,osc,tsc,tSky_CSE,tSky_IR\n");
25152515
}
2516-
fprintf(pF, "%d,%d,%d,%0.1f,%0.1f\n", m, d, h, wd_tSky, tSkyIR);
2516+
fprintf(pF, "%d,%d,%d,%d,%0.1f,%0.1f,%0.1f,%0.1f\n", yr, m, d, h, osc, tsc, wd_tSky, tSkyIR);
25172517
#endif
25182518
}
25192519
return rc;

test/DWHR.cse

Lines changed: 13 additions & 13 deletions
Original file line numberDiff line numberDiff line change
@@ -4538,7 +4538,6 @@ DHWHEATREC DWHR wrFeedsWH=fWH wrCountFXDrain = fxDr wrCountFXCold = fxHR wrCSAR
45384538
//////////////////////////////////////////////////////////////////////
45394539
// Test cases
45404540
//////////////////////////////////////////////////////////////////////
4541-
45424541
// No heat recovery variants -- all should get same results
45434542
// - no DHWHEATREC
45444543
// - DHWHEATREC with EF=0
@@ -4547,14 +4546,21 @@ DO0( "DS0", "Elec0", FX0, WH0, 1)
45474546
DO1( "DS0a", "Elec0a", FX0a, WH0a, 1, 1, 0, Yes, 0)
45484547
DO1( "DS0b", "Elec0b", FX0b, WH0b, 0, 0, 0, No, 0)
45494548

4550-
// fixed heat recovery -- these 2 should get same results
4549+
// fixed heat recovery -- should get same results
45514550
DO0DU( "DSX0", "ElecX0", FXX0, WHX0, "4D7FixedHR", 1)
45524551
DO1DU( "DSX0a", "ElecX0a", FXX0a, WHX0a, "4D7", 1, SetEF, 1, 1, No, .5)
45534552

45544553
DO1( "DSEQ", ElecEQ, FXEQ, WHEQ, 1, 1, 1, Yes, .5)
45554554
DO1( "DSUSH", ElecUSH, FXUSH, WHUSH, 1, 1, 1, No, .5)
45564555
DO1( "DSUWH", ElecUWH, FXUWH, WHUWH, 1, 1, 0, Yes, .5)
45574556

4557+
// 2 showers, 1 DHWHEATREC
4558+
DO1( "DS2S0Y", Elec2S0Y, FX2S0Y, WH2S0Y, 2, 2, 0, Yes, .6)
4559+
DO1( "DS2S1N", Elec2S1N, FX2S1N, WH2S1N, 2, 2, 1, No, .6)
4560+
DO1( "DS2S1Y", Elec2S1Y, FX2S1Y, WH2S1Y, 2, 2, 1, Yes, .6)
4561+
DO1( "DS2S2N", Elec2S2N, FX2S2N, WH2S2N, 2, 2, 2, No, .6)
4562+
DO1( "DS2S2Y", Elec2S2Y, FX2S2Y, WH2S2Y, 2, 2, 2, Yes, .6)
4563+
45584564
// todo -- drain TD
45594565
//////////////////////////////////////////////////////////////////////
45604566

@@ -4581,25 +4587,19 @@ endDHWSYS
45814587
DO0Base0( "DSK1a", "ElecK1a", FXK1a, WHK1a) wsCentralDHWSYS=DSC1 DSLOAD
45824588
DO0Base0( "DSK1b", "ElecK1b", FXK1b, WHK1b) wsCentralDHWSYS=DSC1 DSLOAD
45834589

4584-
45854590
//=====================================================================
4586-
// multi-heater system
4587-
// DSMH0: 1 heater / 2 DHWHEATREC / 2 showers
4588-
// DSMH: 2 subsystems w/ 1 shower, 1 heater, 1 shower
4591+
// multi-heater systems
45894592
// should get same results
45904593

4591-
#if 0
4594+
// DSMH0: 1 heater / 2 DHWHEATREC / 2 showers
45924595
DO2( "DSMH0", ElecMH0, FXMH0, WHMH0, 2, 1, 1, Yes, .6)
45934596

4594-
DO0Base0( "DSMH", ElecMH, FXMH, WHMH) wsDayUse = DHW5BRa endDHWSYS
4595-
4596-
DO0Base( "DSMHKa", ElecMKa, FXMKa, WHMKa, 1) wsLoadShareDHWSYS="DSMH"
4597+
// DSMH: 2 systems each w/ 1 shower, 1 heater, 1 DHWHEATREC
4598+
DO0Base( "DSMH", ElecMH, FXMH, WHMH,1) wsDayUse = DHW5BRa
45974599
DHWHEATREC DWHRa wrFeedsWH=Yes wrCountFXDrain = 1 wrCountFXCold = 1 wrCSARatedEF = .6 wrTDInDiff=0
45984600

4599-
DO0Base( "DSMHKb", ElecMKb, FXMKb, WHMKb, 1) wsLoadShareDHWSYS="DSMH"
4601+
DO0Base( "DSMHKa", ElecMKa, FXMKa, WHMKa, 1) wsLoadShareDHWSYS="DSMH"
46004602
DHWHEATREC DWHRa wrFeedsWH=Yes wrCountFXDrain = 1 wrCountFXCold = 1 wrCSARatedEF = .6 wrTDInDiff=0
4601-
#endif
4602-
46034603

46044604
//////////////////////////////////////////////////////////////////////
46054605

0 commit comments

Comments
 (0)