Can't see the menu entry you are looking for? Document it for your fellow mcHF users! This page is filled in an opportunistic mode (i.e. entries are only documented as needed).
The menu entry is documented but now in a different menu? Move it around. You could describe it better? Do it!
In general the entries will cover the newest version of the software, comments will make sure if there are important differences to older version.
Name | Value Range | Default | Explaination | Comment |
---|---|---|---|---|
A | Dummy | 0 | 1 | Entry |
Name | Value Range | Default | Explaination | Comment |
---|---|---|---|---|
TX Initial Muting Time | 0 - 250ms | 10 | When switching from RX to TX the audio and HF output will be muted for roughly VALUE ms. This does not apply in CW mode. | From 1.5.4 shown as milliseconds (before was 1 == 10ms). Default changed to 10ms, was 0. There are now several minimum times for muting defined in the firmware: Input from Mic: 80ms Input from Line In: 10ms Digital Inputs (CW, USB DIG, USB IQ): about 1.33ms. If the user defined "TX Initial Muting Time" is set to more than zero, the maximum of both fixed input time and user defined time is used. |