Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Running errors #48

Open
Tangbbmc opened this issue Mar 10, 2024 · 4 comments
Open

Running errors #48

Tangbbmc opened this issue Mar 10, 2024 · 4 comments

Comments

@Tangbbmc
Copy link

When I run uni-GBSA using unigbsa-pipline in a batch mode, the following errors occurred. And, the partial results for some ligands did not have energy values (such as B00734_out,1,gb,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,0.0,F_top DB01184_out)

3/10/2024 21:20:44 PM - INFO - Build protein topology.
0%| | 0/37 [00:00<?, ?it/s]export OMP_NUM_THREADS=1;acpype -i /home/dell/Documents/NgIDH_VS/2a_DrugRep/37mol/DB00222_out.mol -b MOL -a gaff -c bcc -n 0 -k "grms_tol=0.005,qm_theory='AM1',scfconv=1.d-8,ndiis_attempts=700,maxcyc=0" -f >acpype.log 2>&1

| ACPYPE: AnteChamber PYthon Parser interfacE v. 2023.10.27 (c) 2024 AWSdS |

==> ... charge set to 0
==> Executing Antechamber...
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR:
Welcome to antechamber 22.0: molecular input file processor.

Info: The atom type is set to gaff; the options available to the -at flag are
gaff, gaff2, amber, bcc, and sybyl.

Info: Determining atomic numbers from atomic symbols which are case sensitive.
Running: /home/dell/anaconda3/envs/gbsa/bin/bondtype -j full -i ANTECHAMBER_BOND_TYPE.AC0 -o ANTECHAMBER_BOND_TYPE.AC -f ac
Warning: The assigned bond types may be wrong, please :
(1) double check the structure (the connectivity) and/or
(2) adjust atom valence penalty parameters in APS.DAT, and/or
(3) increase PSCUTOFF in define.h and recompile bondtype.c
(be cautious, using a large value of PSCUTOFF (>100) will
significantly increase the computation time).

Running: /home/dell/anaconda3/envs/gbsa/bin/atomtype -i ANTECHAMBER_AC.AC0 -o ANTECHAMBER_AC.AC -p gaff
Info: Total number of electrons: 231; net charge: 0
Info: The number of electrons is odd (231).
Please check the total charge (-nc flag) and spin multiplicity (-m flag).

Running: /home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out
/home/dell/anaconda3/envs/gbsa/bin/wrapped_progs/antechamber: Fatal Error!
Cannot properly run "/home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out".

ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Antechamber failed
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Cannot open file (MOL_bcc_gaff.mol2) with mode (r).
No such file or directory
ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Parmchk failed
ERROR: Tleap failed
==> Removing temporary files...
ERROR: ACPYPE FAILED: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Traceback (most recent call last):
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/cli.py", line 138, in init_main
molecule.createMolTopol()
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/topol.py", line 1115, in createMolTopol
self.topFileData = open(self.acTopFileName).readlines()
^^^^^^^^^^^^^^^^^^^^^^^^
FileNotFoundError: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Total time of execution: less than a second
export OMP_NUM_THREADS=1;acpype -i /home/dell/Documents/NgHSD_VS/2a_DrugRep/37mol/DB00398_out.mol -b MOL -a gaff -c bcc -n 0 -k "grms_tol=0.005,qm_theory='AM1',scfconv=1.d-8,ndiis_attempts=700,maxcyc=0" -f >acpype.log 2>&1

| ACPYPE: AnteChamber PYthon Parser interfacE v. 2023.10.27 (c) 2024 AWSdS |

==> ... charge set to 0
==> Executing Antechamber...
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR:
Welcome to antechamber 22.0: molecular input file processor.

Info: The atom type is set to gaff; the options available to the -at flag are
gaff, gaff2, amber, bcc, and sybyl.

Info: Determining atomic numbers from atomic symbols which are case sensitive.
Running: /home/dell/anaconda3/envs/gbsa/bin/bondtype -j full -i ANTECHAMBER_BOND_TYPE.AC0 -o ANTECHAMBER_BOND_TYPE.AC -f ac
Warning: The assigned bond types may be wrong, please :
(1) double check the structure (the connectivity) and/or
(2) adjust atom valence penalty parameters in APS.DAT, and/or
(3) increase PSCUTOFF in define.h and recompile bondtype.c
(be cautious, using a large value of PSCUTOFF (>100) will
significantly increase the computation time).

Running: /home/dell/anaconda3/envs/gbsa/bin/atomtype -i ANTECHAMBER_AC.AC0 -o ANTECHAMBER_AC.AC -p gaff
Info: Total number of electrons: 225; net charge: 0
Info: The number of electrons is odd (225).
Please check the total charge (-nc flag) and spin multiplicity (-m flag).

Running: /home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out
/home/dell/anaconda3/envs/gbsa/bin/wrapped_progs/antechamber: Fatal Error!
Cannot properly run "/home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out".

ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Antechamber failed
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Cannot open file (MOL_bcc_gaff.mol2) with mode (r).
No such file or directory
ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Parmchk failed
ERROR: Tleap failed
==> Removing temporary files...
ERROR: ACPYPE FAILED: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Traceback (most recent call last):
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/cli.py", line 138, in init_main
molecule.createMolTopol()
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/topol.py", line 1115, in createMolTopol
self.topFileData = open(self.acTopFileName).readlines()
^^^^^^^^^^^^^^^^^^^^^^^^
FileNotFoundError: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Total time of execution: less than a second
export OMP_NUM_THREADS=1;acpype -i /home/dell/Documents/NgHSD_VS/2a_DrugRep/37mol/DB00563_out.mol -b MOL -a gaff -c bcc -n 0 -k "grms_tol=0.005,qm_theory='AM1',scfconv=1.d-8,ndiis_attempts=700,maxcyc=0" -f >acpype.log 2>&1

| ACPYPE: AnteChamber PYthon Parser interfacE v. 2023.10.27 (c) 2024 AWSdS |

==> ... charge set to 0
==> Executing Antechamber...
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR:
Welcome to antechamber 22.0: molecular input file processor.

Info: The atom type is set to gaff; the options available to the -at flag are
gaff, gaff2, amber, bcc, and sybyl.

Info: Determining atomic numbers from atomic symbols which are case sensitive.
Running: /home/dell/anaconda3/envs/gbsa/bin/bondtype -j full -i ANTECHAMBER_BOND_TYPE.AC0 -o ANTECHAMBER_BOND_TYPE.AC -f ac
Warning: The assigned bond types may be wrong, please :
(1) double check the structure (the connectivity) and/or
(2) adjust atom valence penalty parameters in APS.DAT, and/or
(3) increase PSCUTOFF in define.h and recompile bondtype.c
(be cautious, using a large value of PSCUTOFF (>100) will
significantly increase the computation time).

Running: /home/dell/anaconda3/envs/gbsa/bin/atomtype -i ANTECHAMBER_AC.AC0 -o ANTECHAMBER_AC.AC -p gaff
Info: Total number of electrons: 223; net charge: 0
Info: The number of electrons is odd (223).
Please check the total charge (-nc flag) and spin multiplicity (-m flag).

Running: /home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out
/home/dell/anaconda3/envs/gbsa/bin/wrapped_progs/antechamber: Fatal Error!
Cannot properly run "/home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out".

ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Antechamber failed
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Cannot open file (MOL_bcc_gaff.mol2) with mode (r).
No such file or directory
ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Parmchk failed
ERROR: Tleap failed
==> Removing temporary files...
ERROR: ACPYPE FAILED: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Traceback (most recent call last):
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/cli.py", line 138, in init_main
molecule.createMolTopol()
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/topol.py", line 1115, in createMolTopol
self.topFileData = open(self.acTopFileName).readlines()
^^^^^^^^^^^^^^^^^^^^^^^^
FileNotFoundError: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Total time of execution: less than a second
export OMP_NUM_THREADS=1;acpype -i /home/dell/Documents/NgHSD_VS/2a_DrugRep/37mol/DB00590_out.mol -b MOL -a gaff -c bcc -n 0 -k "grms_tol=0.005,qm_theory='AM1',scfconv=1.d-8,ndiis_attempts=700,maxcyc=0" -f >acpype.log 2>&1

| ACPYPE: AnteChamber PYthon Parser interfacE v. 2023.10.27 (c) 2024 AWSdS |

==> ... charge set to 0
==> Executing Antechamber...
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR:
Welcome to antechamber 22.0: molecular input file processor.

Info: The atom type is set to gaff; the options available to the -at flag are
gaff, gaff2, amber, bcc, and sybyl.

Info: Determining atomic numbers from atomic symbols which are case sensitive.
Running: /home/dell/anaconda3/envs/gbsa/bin/bondtype -j full -i ANTECHAMBER_BOND_TYPE.AC0 -o ANTECHAMBER_BOND_TYPE.AC -f ac
Warning: The assigned bond types may be wrong, please :
(1) double check the structure (the connectivity) and/or
(2) adjust atom valence penalty parameters in APS.DAT, and/or
(3) increase PSCUTOFF in define.h and recompile bondtype.c
(be cautious, using a large value of PSCUTOFF (>100) will
significantly increase the computation time).

Running: /home/dell/anaconda3/envs/gbsa/bin/atomtype -i ANTECHAMBER_AC.AC0 -o ANTECHAMBER_AC.AC -p gaff
Info: Total number of electrons: 215; net charge: 0
Info: The number of electrons is odd (215).
Please check the total charge (-nc flag) and spin multiplicity (-m flag).

Running: /home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out
/home/dell/anaconda3/envs/gbsa/bin/wrapped_progs/antechamber: Fatal Error!
Cannot properly run "/home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out".

ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Antechamber failed
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Cannot open file (MOL_bcc_gaff.mol2) with mode (r).
No such file or directory
ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Parmchk failed
ERROR: Tleap failed
==> Removing temporary files...
ERROR: ACPYPE FAILED: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Traceback (most recent call last):
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/cli.py", line 138, in init_main
molecule.createMolTopol()
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/topol.py", line 1115, in createMolTopol
self.topFileData = open(self.acTopFileName).readlines()
^^^^^^^^^^^^^^^^^^^^^^^^
FileNotFoundError: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Total time of execution: less than a second
export OMP_NUM_THREADS=1;acpype -i /home/dell/Documents/NgHSD_VS/2a_DrugRep/37mol/DB00619_out.mol -b MOL -a gaff -c bcc -n 0 -k "grms_tol=0.005,qm_theory='AM1',scfconv=1.d-8,ndiis_attempts=700,maxcyc=0" -f >acpype.log 2>&1

| ACPYPE: AnteChamber PYthon Parser interfacE v. 2023.10.27 (c) 2024 AWSdS |

==> ... charge set to 0
==> Executing Antechamber...
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR:
Welcome to antechamber 22.0: molecular input file processor.

Info: The atom type is set to gaff; the options available to the -at flag are
gaff, gaff2, amber, bcc, and sybyl.

Info: Determining atomic numbers from atomic symbols which are case sensitive.
Running: /home/dell/anaconda3/envs/gbsa/bin/bondtype -j full -i ANTECHAMBER_BOND_TYPE.AC0 -o ANTECHAMBER_BOND_TYPE.AC -f ac
Warning: The assigned bond types may be wrong, please :
(1) double check the structure (the connectivity) and/or
(2) adjust atom valence penalty parameters in APS.DAT, and/or
(3) increase PSCUTOFF in define.h and recompile bondtype.c
(be cautious, using a large value of PSCUTOFF (>100) will
significantly increase the computation time).

Running: /home/dell/anaconda3/envs/gbsa/bin/atomtype -i ANTECHAMBER_AC.AC0 -o ANTECHAMBER_AC.AC -p gaff
Info: Total number of electrons: 233; net charge: 0
Info: The number of electrons is odd (233).
Please check the total charge (-nc flag) and spin multiplicity (-m flag).

Running: /home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out
/home/dell/anaconda3/envs/gbsa/bin/wrapped_progs/antechamber: Fatal Error!
Cannot properly run "/home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out".

ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Antechamber failed
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Cannot open file (MOL_bcc_gaff.mol2) with mode (r).
No such file or directory
ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Parmchk failed
ERROR: Tleap failed
==> Removing temporary files...
ERROR: ACPYPE FAILED: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Traceback (most recent call last):
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/cli.py", line 138, in init_main
molecule.createMolTopol()
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/topol.py", line 1115, in createMolTopol
self.topFileData = open(self.acTopFileName).readlines()
^^^^^^^^^^^^^^^^^^^^^^^^
FileNotFoundError: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Total time of execution: less than a second
export OMP_NUM_THREADS=1;acpype -i /home/dell/Documents/NgHSD_VS/2a_DrugRep/37mol/DB00734_out.mol -b MOL -a gaff -c bcc -n 0 -k "grms_tol=0.005,qm_theory='AM1',scfconv=1.d-8,ndiis_attempts=700,maxcyc=0" -f >acpype.log 2>&1

| ACPYPE: AnteChamber PYthon Parser interfacE v. 2023.10.27 (c) 2024 AWSdS |

==> ... charge set to 0
==> Executing Antechamber...
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR:
Welcome to antechamber 22.0: molecular input file processor.

Info: The atom type is set to gaff; the options available to the -at flag are
gaff, gaff2, amber, bcc, and sybyl.

Info: Determining atomic numbers from atomic symbols which are case sensitive.
Running: /home/dell/anaconda3/envs/gbsa/bin/bondtype -j full -i ANTECHAMBER_BOND_TYPE.AC0 -o ANTECHAMBER_BOND_TYPE.AC -f ac
Warning: The assigned bond types may be wrong, please :
(1) double check the structure (the connectivity) and/or
(2) adjust atom valence penalty parameters in APS.DAT, and/or
(3) increase PSCUTOFF in define.h and recompile bondtype.c
(be cautious, using a large value of PSCUTOFF (>100) will
significantly increase the computation time).

Running: /home/dell/anaconda3/envs/gbsa/bin/atomtype -i ANTECHAMBER_AC.AC0 -o ANTECHAMBER_AC.AC -p gaff
Info: Total number of electrons: 191; net charge: 0
Info: The number of electrons is odd (191).
Please check the total charge (-nc flag) and spin multiplicity (-m flag).

Running: /home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out
/home/dell/anaconda3/envs/gbsa/bin/wrapped_progs/antechamber: Fatal Error!
Cannot properly run "/home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out".

ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Antechamber failed
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Cannot open file (MOL_bcc_gaff.mol2) with mode (r).
No such file or directory
ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Parmchk failed
ERROR: Tleap failed
==> Removing temporary files...
ERROR: ACPYPE FAILED: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Traceback (most recent call last):
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/cli.py", line 138, in init_main
molecule.createMolTopol()
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/topol.py", line 1115, in createMolTopol
self.topFileData = open(self.acTopFileName).readlines()
^^^^^^^^^^^^^^^^^^^^^^^^
FileNotFoundError: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Total time of execution: less than a second
export OMP_NUM_THREADS=1;acpype -i /home/dell/Documents/NgHSD_VS/2a_DrugRep/37mol/DB01251_out.mol -b MOL -a gaff -c bcc -n 0 -k "grms_tol=0.005,qm_theory='AM1',scfconv=1.d-8,ndiis_attempts=700,maxcyc=0" -f >acpype.log 2>&1

| ACPYPE: AnteChamber PYthon Parser interfacE v. 2023.10.27 (c) 2024 AWSdS |

==> ... charge set to 0
==> Executing Antechamber...
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR:
Welcome to antechamber 22.0: molecular input file processor.

Info: The atom type is set to gaff; the options available to the -at flag are
gaff, gaff2, amber, bcc, and sybyl.

Info: Determining atomic numbers from atomic symbols which are case sensitive.
Running: /home/dell/anaconda3/envs/gbsa/bin/bondtype -j full -i ANTECHAMBER_BOND_TYPE.AC0 -o ANTECHAMBER_BOND_TYPE.AC -f ac
Warning: The assigned bond types may be wrong, please :
(1) double check the structure (the connectivity) and/or
(2) adjust atom valence penalty parameters in APS.DAT, and/or
(3) increase PSCUTOFF in define.h and recompile bondtype.c
(be cautious, using a large value of PSCUTOFF (>100) will
significantly increase the computation time).

Running: /home/dell/anaconda3/envs/gbsa/bin/atomtype -i ANTECHAMBER_AC.AC0 -o ANTECHAMBER_AC.AC -p gaff
Info: Total number of electrons: 249; net charge: 0
Info: The number of electrons is odd (249).
Please check the total charge (-nc flag) and spin multiplicity (-m flag).

Running: /home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out
/home/dell/anaconda3/envs/gbsa/bin/wrapped_progs/antechamber: Fatal Error!
Cannot properly run "/home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out".

ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Antechamber failed
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Cannot open file (MOL_bcc_gaff.mol2) with mode (r).
No such file or directory
ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Parmchk failed
ERROR: Tleap failed
==> Removing temporary files...
ERROR: ACPYPE FAILED: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Traceback (most recent call last):
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/cli.py", line 138, in init_main
molecule.createMolTopol()
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/topol.py", line 1115, in createMolTopol
self.topFileData = open(self.acTopFileName).readlines()
^^^^^^^^^^^^^^^^^^^^^^^^
FileNotFoundError: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Total time of execution: less than a second
export OMP_NUM_THREADS=1;acpype -i /home/dell/Documents/NgHSD_VS/2a_DrugRep/37mol/DB01396_out.mol -b MOL -a gaff -c bcc -n 0 -k "grms_tol=0.005,qm_theory='AM1',scfconv=1.d-8,ndiis_attempts=700,maxcyc=0" -f >acpype.log 2>&1

| ACPYPE: AnteChamber PYthon Parser interfacE v. 2023.10.27 (c) 2024 AWSdS |

==> ... charge set to 0
==> Executing Antechamber...
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR:
Welcome to antechamber 22.0: molecular input file processor.

Info: The atom type is set to gaff; the options available to the -at flag are
gaff, gaff2, amber, bcc, and sybyl.

Info: Determining atomic numbers from atomic symbols which are case sensitive.
Running: /home/dell/anaconda3/envs/gbsa/bin/bondtype -j full -i ANTECHAMBER_BOND_TYPE.AC0 -o ANTECHAMBER_BOND_TYPE.AC -f ac
Warning: The assigned bond types may be wrong, please :
(1) double check the structure (the connectivity) and/or
(2) adjust atom valence penalty parameters in APS.DAT, and/or
(3) increase PSCUTOFF in define.h and recompile bondtype.c
(be cautious, using a large value of PSCUTOFF (>100) will
significantly increase the computation time).

Running: /home/dell/anaconda3/envs/gbsa/bin/atomtype -i ANTECHAMBER_AC.AC0 -o ANTECHAMBER_AC.AC -p gaff
Info: Total number of electrons: 355; net charge: 0
Info: The number of electrons is odd (355).
Please check the total charge (-nc flag) and spin multiplicity (-m flag).

Running: /home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out
/home/dell/anaconda3/envs/gbsa/bin/wrapped_progs/antechamber: Fatal Error!
Cannot properly run "/home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out".

ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Antechamber failed
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Cannot open file (MOL_bcc_gaff.mol2) with mode (r).
No such file or directory
ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Parmchk failed
ERROR: Tleap failed
==> Removing temporary files...
ERROR: ACPYPE FAILED: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Traceback (most recent call last):
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/cli.py", line 138, in init_main
molecule.createMolTopol()
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/topol.py", line 1115, in createMolTopol
self.topFileData = open(self.acTopFileName).readlines()
^^^^^^^^^^^^^^^^^^^^^^^^
FileNotFoundError: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Total time of execution: less than a second
export OMP_NUM_THREADS=1;acpype -i /home/dell/Documents/NgHSD_VS/2a_DrugRep/37mol/DB00511_out.mol -b MOL -a gaff -c bcc -n 0 -k "grms_tol=0.005,qm_theory='AM1',scfconv=1.d-8,ndiis_attempts=700,maxcyc=0" -f >acpype.log 2>&1

| ACPYPE: AnteChamber PYthon Parser interfacE v. 2023.10.27 (c) 2024 AWSdS |

==> ... charge set to 0
==> Executing Antechamber...
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR:
Welcome to antechamber 22.0: molecular input file processor.

Info: The atom type is set to gaff; the options available to the -at flag are
gaff, gaff2, amber, bcc, and sybyl.

Info: Determining atomic numbers from atomic symbols which are case sensitive.
Running: /home/dell/anaconda3/envs/gbsa/bin/bondtype -j full -i ANTECHAMBER_BOND_TYPE.AC0 -o ANTECHAMBER_BOND_TYPE.AC -f ac
Warning: The assigned bond types may be wrong, please :
(1) double check the structure (the connectivity) and/or
(2) adjust atom valence penalty parameters in APS.DAT, and/or
(3) increase PSCUTOFF in define.h and recompile bondtype.c
(be cautious, using a large value of PSCUTOFF (>100) will
significantly increase the computation time).

Running: /home/dell/anaconda3/envs/gbsa/bin/atomtype -i ANTECHAMBER_AC.AC0 -o ANTECHAMBER_AC.AC -p gaff
Info: Total number of electrons: 374; net charge: 0

Running: /home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out
/home/dell/anaconda3/envs/gbsa/bin/wrapped_progs/antechamber: Fatal Error!
Cannot properly run "/home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out".

ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Antechamber failed
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Cannot open file (MOL_bcc_gaff.mol2) with mode (r).
No such file or directory
ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Parmchk failed
ERROR: Tleap failed
==> Removing temporary files...
ERROR: ACPYPE FAILED: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Traceback (most recent call last):
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/cli.py", line 138, in init_main
molecule.createMolTopol()
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/topol.py", line 1115, in createMolTopol
self.topFileData = open(self.acTopFileName).readlines()
^^^^^^^^^^^^^^^^^^^^^^^^
FileNotFoundError: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Total time of execution: 7s
export OMP_NUM_THREADS=1;acpype -i /home/dell/Documents/NgHSD_VS/2a_DrugRep/37mol/DB06144_out.mol -b MOL -a gaff -c bcc -n 0 -k "grms_tol=0.005,qm_theory='AM1',scfconv=1.d-8,ndiis_attempts=700,maxcyc=0" -f >acpype.log 2>&1

| ACPYPE: AnteChamber PYthon Parser interfacE v. 2023.10.27 (c) 2024 AWSdS |

==> ... charge set to 0
==> Executing Antechamber...
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR:
Welcome to antechamber 22.0: molecular input file processor.

Info: The atom type is set to gaff; the options available to the -at flag are
gaff, gaff2, amber, bcc, and sybyl.

Info: Determining atomic numbers from atomic symbols which are case sensitive.
Running: /home/dell/anaconda3/envs/gbsa/bin/bondtype -j full -i ANTECHAMBER_BOND_TYPE.AC0 -o ANTECHAMBER_BOND_TYPE.AC -f ac
Warning: The assigned bond types may be wrong, please :
(1) double check the structure (the connectivity) and/or
(2) adjust atom valence penalty parameters in APS.DAT, and/or
(3) increase PSCUTOFF in define.h and recompile bondtype.c
(be cautious, using a large value of PSCUTOFF (>100) will
significantly increase the computation time).

Running: /home/dell/anaconda3/envs/gbsa/bin/atomtype -i ANTECHAMBER_AC.AC0 -o ANTECHAMBER_AC.AC -p gaff
Info: Total number of electrons: 207; net charge: 0
Info: The number of electrons is odd (207).
Please check the total charge (-nc flag) and spin multiplicity (-m flag).

Running: /home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out
/home/dell/anaconda3/envs/gbsa/bin/wrapped_progs/antechamber: Fatal Error!
Cannot properly run "/home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out".

ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Antechamber failed
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Cannot open file (MOL_bcc_gaff.mol2) with mode (r).
No such file or directory
ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Parmchk failed
ERROR: Tleap failed
==> Removing temporary files...
ERROR: ACPYPE FAILED: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Traceback (most recent call last):
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/cli.py", line 138, in init_main
molecule.createMolTopol()
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/topol.py", line 1115, in createMolTopol
self.topFileData = open(self.acTopFileName).readlines()
^^^^^^^^^^^^^^^^^^^^^^^^
FileNotFoundError: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Total time of execution: less than a second
03/10/2024 21:21:03 PM - INFO - Run the MMPB(GB)SA.
export OMP_NUM_THREADS=1;acpype -i /home/dell/Documents/NgHSD_VS/2a_DrugRep/37mol/DB09078_out.mol -b MOL -a gaff -c bcc -n 0 -k "grms_tol=0.005,qm_theory='AM1',scfconv=1.d-8,ndiis_attempts=700,maxcyc=0" -f >acpype.log 2>&1

| ACPYPE: AnteChamber PYthon Parser interfacE v. 2023.10.27 (c) 2024 AWSdS |

==> ... charge set to 0
==> Executing Antechamber...
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR:
Welcome to antechamber 22.0: molecular input file processor.

Info: The atom type is set to gaff; the options available to the -at flag are
gaff, gaff2, amber, bcc, and sybyl.

Info: Determining atomic numbers from atomic symbols which are case sensitive.
Running: /home/dell/anaconda3/envs/gbsa/bin/bondtype -j full -i ANTECHAMBER_BOND_TYPE.AC0 -o ANTECHAMBER_BOND_TYPE.AC -f ac
Warning: The assigned bond types may be wrong, please :
(1) double check the structure (the connectivity) and/or
(2) adjust atom valence penalty parameters in APS.DAT, and/or
(3) increase PSCUTOFF in define.h and recompile bondtype.c
(be cautious, using a large value of PSCUTOFF (>100) will
significantly increase the computation time).

Running: /home/dell/anaconda3/envs/gbsa/bin/atomtype -i ANTECHAMBER_AC.AC0 -o ANTECHAMBER_AC.AC -p gaff
Info: Total number of electrons: 207; net charge: 0
Info: The number of electrons is odd (207).
Please check the total charge (-nc flag) and spin multiplicity (-m flag).

Running: /home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out
/home/dell/anaconda3/envs/gbsa/bin/wrapped_progs/antechamber: Fatal Error!
Cannot properly run "/home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out".

ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Antechamber failed
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Cannot open file (MOL_bcc_gaff.mol2) with mode (r).
No such file or directory
ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Parmchk failed
ERROR: Tleap failed
==> Removing temporary files...
ERROR: ACPYPE FAILED: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Traceback (most recent call last):
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/cli.py", line 138, in init_main
molecule.createMolTopol()
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/topol.py", line 1115, in createMolTopol
self.topFileData = open(self.acTopFileName).readlines()
^^^^^^^^^^^^^^^^^^^^^^^^
FileNotFoundError: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Total time of execution: less than a second
03/10/2024 21:21:04 PM - INFO - Run the MMPB(GB)SA.
export OMP_NUM_THREADS=1;acpype -i /home/dell/Documents/NgHSD_VS/2a_DrugRep/37mol/DB09079_out.mol -b MOL -a gaff -c bcc -n 0 -k "grms_tol=0.005,qm_theory='AM1',scfconv=1.d-8,ndiis_attempts=700,maxcyc=0" -f >acpype.log 2>&1

| ACPYPE: AnteChamber PYthon Parser interfacE v. 2023.10.27 (c) 2024 AWSdS |

==> ... charge set to 0
==> Executing Antechamber...
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR:
Welcome to antechamber 22.0: molecular input file processor.

Info: The atom type is set to gaff; the options available to the -at flag are
gaff, gaff2, amber, bcc, and sybyl.

Info: Determining atomic numbers from atomic symbols which are case sensitive.
Running: /home/dell/anaconda3/envs/gbsa/bin/bondtype -j full -i ANTECHAMBER_BOND_TYPE.AC0 -o ANTECHAMBER_BOND_TYPE.AC -f ac
Warning: The assigned bond types may be wrong, please :
(1) double check the structure (the connectivity) and/or
(2) adjust atom valence penalty parameters in APS.DAT, and/or
(3) increase PSCUTOFF in define.h and recompile bondtype.c
(be cautious, using a large value of PSCUTOFF (>100) will
significantly increase the computation time).

Running: /home/dell/anaconda3/envs/gbsa/bin/atomtype -i ANTECHAMBER_AC.AC0 -o ANTECHAMBER_AC.AC -p gaff
Info: Total number of electrons: 255; net charge: 0
Info: The number of electrons is odd (255).
Please check the total charge (-nc flag) and spin multiplicity (-m flag).

Running: /home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out
/home/dell/anaconda3/envs/gbsa/bin/wrapped_progs/antechamber: Fatal Error!
Cannot properly run "/home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out".

ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Antechamber failed
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Cannot open file (MOL_bcc_gaff.mol2) with mode (r).
No such file or directory
ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Parmchk failed
ERROR: Tleap failed
==> Removing temporary files...
ERROR: ACPYPE FAILED: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Traceback (most recent call last):
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/cli.py", line 138, in init_main
molecule.createMolTopol()
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/topol.py", line 1115, in createMolTopol
self.topFileData = open(self.acTopFileName).readlines()
^^^^^^^^^^^^^^^^^^^^^^^^
FileNotFoundError: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Total time of execution: less than a second
03/10/2024 21:21:07 PM - INFO - Run the MMPB(GB)SA.
export OMP_NUM_THREADS=1;acpype -i /home/dell/Documents/NgHSD_VS/2a_DrugRep/37mol/DB11256_out.mol -b MOL -a gaff -c bcc -n 0 -k "grms_tol=0.005,qm_theory='AM1',scfconv=1.d-8,ndiis_attempts=700,maxcyc=0" -f >acpype.log 2>&1

| ACPYPE: AnteChamber PYthon Parser interfacE v. 2023.10.27 (c) 2024 AWSdS |

==> ... charge set to 0
==> Executing Antechamber...
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR:
Welcome to antechamber 22.0: molecular input file processor.

Info: The atom type is set to gaff; the options available to the -at flag are
gaff, gaff2, amber, bcc, and sybyl.

Info: Determining atomic numbers from atomic symbols which are case sensitive.
Running: /home/dell/anaconda3/envs/gbsa/bin/bondtype -j full -i ANTECHAMBER_BOND_TYPE.AC0 -o ANTECHAMBER_BOND_TYPE.AC -f ac
Warning: The assigned bond types may be wrong, please :
(1) double check the structure (the connectivity) and/or
(2) adjust atom valence penalty parameters in APS.DAT, and/or
(3) increase PSCUTOFF in define.h and recompile bondtype.c
(be cautious, using a large value of PSCUTOFF (>100) will
significantly increase the computation time).

Running: /home/dell/anaconda3/envs/gbsa/bin/atomtype -i ANTECHAMBER_AC.AC0 -o ANTECHAMBER_AC.AC -p gaff
Info: Total number of electrons: 225; net charge: 0
Info: The number of electrons is odd (225).
Please check the total charge (-nc flag) and spin multiplicity (-m flag).

Running: /home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out
/home/dell/anaconda3/envs/gbsa/bin/wrapped_progs/antechamber: Fatal Error!
Cannot properly run "/home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out".

ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Antechamber failed
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Cannot open file (MOL_bcc_gaff.mol2) with mode (r).
No such file or directory
ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Parmchk failed
ERROR: Tleap failed
==> Removing temporary files...
ERROR: ACPYPE FAILED: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Traceback (most recent call last):
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/cli.py", line 138, in init_main
molecule.createMolTopol()
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/topol.py", line 1115, in createMolTopol
self.topFileData = open(self.acTopFileName).readlines()
^^^^^^^^^^^^^^^^^^^^^^^^
FileNotFoundError: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Total time of execution: less than a second
03/10/2024 21:21:11 PM - INFO - Run the MMPB(GB)SA.
03/10/2024 21:21:12 PM - INFO - Run the MMPB(GB)SA.
export OMP_NUM_THREADS=1;acpype -i /home/dell/Documents/NgHSD_VS/2a_DrugRep/37mol/DB11581_out.mol -b MOL -a gaff -c bcc -n 0 -k "grms_tol=0.005,qm_theory='AM1',scfconv=1.d-8,ndiis_attempts=700,maxcyc=0" -f >acpype.log 2>&1

| ACPYPE: AnteChamber PYthon Parser interfacE v. 2023.10.27 (c) 2024 AWSdS |

==> ... charge set to 0
==> Executing Antechamber...
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR:
Welcome to antechamber 22.0: molecular input file processor.

Info: The atom type is set to gaff; the options available to the -at flag are
gaff, gaff2, amber, bcc, and sybyl.

Info: Determining atomic numbers from atomic symbols which are case sensitive.
Running: /home/dell/anaconda3/envs/gbsa/bin/bondtype -j full -i ANTECHAMBER_BOND_TYPE.AC0 -o ANTECHAMBER_BOND_TYPE.AC -f ac
Warning: The assigned bond types may be wrong, please :
(1) double check the structure (the connectivity) and/or
(2) adjust atom valence penalty parameters in APS.DAT, and/or
(3) increase PSCUTOFF in define.h and recompile bondtype.c
(be cautious, using a large value of PSCUTOFF (>100) will
significantly increase the computation time).

Running: /home/dell/anaconda3/envs/gbsa/bin/atomtype -i ANTECHAMBER_AC.AC0 -o ANTECHAMBER_AC.AC -p gaff
Info: Total number of electrons: 411; net charge: 0
Info: The number of electrons is odd (411).
Please check the total charge (-nc flag) and spin multiplicity (-m flag).

Running: /home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out
/home/dell/anaconda3/envs/gbsa/bin/wrapped_progs/antechamber: Fatal Error!
Cannot properly run "/home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out".

ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Antechamber failed
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Cannot open file (MOL_bcc_gaff.mol2) with mode (r).
No such file or directory
ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Parmchk failed
ERROR: Tleap failed
==> Removing temporary files...
ERROR: ACPYPE FAILED: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Traceback (most recent call last):
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/cli.py", line 138, in init_main
molecule.createMolTopol()
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/topol.py", line 1115, in createMolTopol
self.topFileData = open(self.acTopFileName).readlines()
^^^^^^^^^^^^^^^^^^^^^^^^
FileNotFoundError: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Total time of execution: less than a second
export OMP_NUM_THREADS=1;acpype -i /home/dell/Documents/NgHSD_VS/2a_DrugRep/37mol/DB11596_out.mol -b MOL -a gaff -c bcc -n 0 -k "grms_tol=0.005,qm_theory='AM1',scfconv=1.d-8,ndiis_attempts=700,maxcyc=0" -f >acpype.log 2>&1

| ACPYPE: AnteChamber PYthon Parser interfacE v. 2023.10.27 (c) 2024 AWSdS |

==> ... charge set to 0
==> Executing Antechamber...
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR:
Welcome to antechamber 22.0: molecular input file processor.

Info: The atom type is set to gaff; the options available to the -at flag are
gaff, gaff2, amber, bcc, and sybyl.

Info: Determining atomic numbers from atomic symbols which are case sensitive.
Running: /home/dell/anaconda3/envs/gbsa/bin/bondtype -j full -i ANTECHAMBER_BOND_TYPE.AC0 -o ANTECHAMBER_BOND_TYPE.AC -f ac
Warning: The assigned bond types may be wrong, please :
(1) double check the structure (the connectivity) and/or
(2) adjust atom valence penalty parameters in APS.DAT, and/or
(3) increase PSCUTOFF in define.h and recompile bondtype.c
(be cautious, using a large value of PSCUTOFF (>100) will
significantly increase the computation time).

Running: /home/dell/anaconda3/envs/gbsa/bin/atomtype -i ANTECHAMBER_AC.AC0 -o ANTECHAMBER_AC.AC -p gaff
Info: Total number of electrons: 233; net charge: 0
Info: The number of electrons is odd (233).
Please check the total charge (-nc flag) and spin multiplicity (-m flag).

Running: /home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out
/home/dell/anaconda3/envs/gbsa/bin/wrapped_progs/antechamber: Fatal Error!
Cannot properly run "/home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out".

ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Antechamber failed
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Cannot open file (MOL_bcc_gaff.mol2) with mode (r).
No such file or directory
ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Parmchk failed
ERROR: Tleap failed
==> Removing temporary files...
ERROR: ACPYPE FAILED: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Traceback (most recent call last):
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/cli.py", line 138, in init_main
molecule.createMolTopol()
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/topol.py", line 1115, in createMolTopol
self.topFileData = open(self.acTopFileName).readlines()
^^^^^^^^^^^^^^^^^^^^^^^^
FileNotFoundError: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Total time of execution: less than a second
03/10/2024 21:21:13 PM - INFO - Run the MMPB(GB)SA.
03/10/2024 21:21:13 PM - INFO - Run the MMPB(GB)SA.
export OMP_NUM_THREADS=1;acpype -i /home/dell/Documents/NgHSD_VS/2a_DrugRep/37mol/DB11732_out.mol -b MOL -a gaff -c bcc -n 0 -k "grms_tol=0.005,qm_theory='AM1',scfconv=1.d-8,ndiis_attempts=700,maxcyc=0" -f >acpype.log 2>&1

| ACPYPE: AnteChamber PYthon Parser interfacE v. 2023.10.27 (c) 2024 AWSdS |

==> ... charge set to 0
==> Executing Antechamber...
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR:
Welcome to antechamber 22.0: molecular input file processor.

Info: The atom type is set to gaff; the options available to the -at flag are
gaff, gaff2, amber, bcc, and sybyl.

Info: Determining atomic numbers from atomic symbols which are case sensitive.
Running: /home/dell/anaconda3/envs/gbsa/bin/bondtype -j full -i ANTECHAMBER_BOND_TYPE.AC0 -o ANTECHAMBER_BOND_TYPE.AC -f ac
Warning: The assigned bond types may be wrong, please :
(1) double check the structure (the connectivity) and/or
(2) adjust atom valence penalty parameters in APS.DAT, and/or
(3) increase PSCUTOFF in define.h and recompile bondtype.c
(be cautious, using a large value of PSCUTOFF (>100) will
significantly increase the computation time).

Running: /home/dell/anaconda3/envs/gbsa/bin/atomtype -i ANTECHAMBER_AC.AC0 -o ANTECHAMBER_AC.AC -p gaff
Info: Total number of electrons: 179; net charge: 0
Info: The number of electrons is odd (179).
Please check the total charge (-nc flag) and spin multiplicity (-m flag).

Running: /home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out
/home/dell/anaconda3/envs/gbsa/bin/wrapped_progs/antechamber: Fatal Error!
Cannot properly run "/home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out".

ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Antechamber failed
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Cannot open file (MOL_bcc_gaff.mol2) with mode (r).
No such file or directory
ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Parmchk failed
ERROR: Tleap failed
==> Removing temporary files...
ERROR: ACPYPE FAILED: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Traceback (most recent call last):
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/cli.py", line 138, in init_main
molecule.createMolTopol()
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/topol.py", line 1115, in createMolTopol
self.topFileData = open(self.acTopFileName).readlines()
^^^^^^^^^^^^^^^^^^^^^^^^
FileNotFoundError: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Total time of execution: less than a second
export OMP_NUM_THREADS=1;acpype -i /home/dell/Documents/NgHSD_VS/2a_DrugRep/37mol/DB12978_out.mol -b MOL -a gaff -c bcc -n 0 -k "grms_tol=0.005,qm_theory='AM1',scfconv=1.d-8,ndiis_attempts=700,maxcyc=0" -f >acpype.log 2>&1

| ACPYPE: AnteChamber PYthon Parser interfacE v. 2023.10.27 (c) 2024 AWSdS |

==> ... charge set to 0
==> Executing Antechamber...
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR:
Welcome to antechamber 22.0: molecular input file processor.

Info: The atom type is set to gaff; the options available to the -at flag are
gaff, gaff2, amber, bcc, and sybyl.

Info: Determining atomic numbers from atomic symbols which are case sensitive.
Running: /home/dell/anaconda3/envs/gbsa/bin/bondtype -j full -i ANTECHAMBER_BOND_TYPE.AC0 -o ANTECHAMBER_BOND_TYPE.AC -f ac
Warning: The assigned bond types may be wrong, please :
(1) double check the structure (the connectivity) and/or
(2) adjust atom valence penalty parameters in APS.DAT, and/or
(3) increase PSCUTOFF in define.h and recompile bondtype.c
(be cautious, using a large value of PSCUTOFF (>100) will
significantly increase the computation time).

Running: /home/dell/anaconda3/envs/gbsa/bin/atomtype -i ANTECHAMBER_AC.AC0 -o ANTECHAMBER_AC.AC -p gaff
Info: Total number of electrons: 201; net charge: 0
Info: The number of electrons is odd (201).
Please check the total charge (-nc flag) and spin multiplicity (-m flag).

Running: /home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out
/home/dell/anaconda3/envs/gbsa/bin/wrapped_progs/antechamber: Fatal Error!
Cannot properly run "/home/dell/anaconda3/envs/gbsa/bin/sqm -O -i sqm.in -o sqm.out".

ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Antechamber failed
ERROR: ++++++++++start_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Cannot open file (MOL_bcc_gaff.mol2) with mode (r).
No such file or directory
ERROR: ++++++++++end_quote+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ERROR: Parmchk failed
ERROR: Tleap failed
==> Removing temporary files...
ERROR: ACPYPE FAILED: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Traceback (most recent call last):
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/cli.py", line 138, in init_main
molecule.createMolTopol()
File "/home/dell/anaconda3/envs/gbsa/lib/python3.12/site-packages/acpype/topol.py", line 1115, in createMolTopol
self.topFileData = open(self.acTopFileName).readlines()
^^^^^^^^^^^^^^^^^^^^^^^^
FileNotFoundError: [Errno 2] No such file or directory: 'MOL_AC.prmtop'
Total time of execution: less than a second
03/10/2024 21:21:21 PM - INFO - Run the MMPB(GB)SA.
03/10/2024 21:21:22 PM - INFO - Run the MMPB(GB)SA.
03/10/2024 21:21:22 PM - INFO - Run the MMPB(GB)SA.
03/10/2024 21:21:23 PM - INFO - Run the MMPB(GB)SA.
03/10/2024 21:21:23 PM - INFO - Run the MMPB(GB)SA.
03/10/2024 21:21:27 PM - INFO - Run the MMPB(GB)SA.
03/10/2024 21:21:31 PM - INFO - Run the MMPB(GB)SA.
03/10/2024 21:21:32 PM - INFO - Run the MMPB(GB)SA.
03/10/2024 21:21:36 PM - INFO - Run the MMPB(GB)SA.
03/10/2024 21:21:37 PM - INFO - Run the MMPB(GB)SA.
03/10/2024 21:21:38 PM - INFO - Run the MMPB(GB)SA.
03/10/2024 21:21:40 PM - INFO - Run the MMPB(GB)SA.
03/10/2024 21:22:07 PM - INFO - Run the MMPB(GB)SA.
03/10/2024 21:23:00 PM - INFO - Clean the results.

Results: Energy.csv Dec.csv
Frames mode detal_G(kcal/mole)
1 gb -50.4484
03/10/2024 21:23:03 PM - INFO - Clean the results.

Results: Energy.csv Dec.csv
Frames mode detal_G(kcal/mole)
1 gb -53.8445
03/10/2024 21:23:05 PM - INFO - Clean the results.

Results: Energy.csv Dec.csv
Frames mode detal_G(kcal/mole)
1 gb -44.0138
3%|█ | 1/37 [02:17<1:22:19, 137.21s/it]03/10/2024 21:23:08 PM - INFO - Clean the results.

Results: Energy.csv Dec.csv
Frames mode detal_G(kcal/mole)
1 gb -42.8089
03/10/2024 21:23:10 PM - INFO - Clean the results.
03/10/2024 21:23:10 PM - INFO - Clean the results.

Results: Energy.csv Dec.csv
Frames mode detal_G(kcal/mole)
1 gb -47.3233

Results: Energy.csv Dec.csv
Frames mode detal_G(kcal/mole)
1 gb -45.4563
8%|███▌ | 3/37 [02:22<21:16, 37.54s/it]03/10/2024 21:23:16 PM - INFO - Clean the results.

Results: Energy.csv Dec.csv
Frames mode detal_G(kcal/mole)
1 gb -50.4495
03/10/2024 21:23:17 PM - INFO - Clean the results.
03/10/2024 21:23:17 PM - INFO - Clean the results.

Results: Energy.csv Dec.csv
Frames mode detal_G(kcal/mole)
1 gb -46.7604

Results: Energy.csv Dec.csv
Frames mode detal_G(kcal/mole)
1 gb -46.0066
03/10/2024 21:23:18 PM - INFO - Clean the results.

Results: Energy.csv Dec.csv
Frames mode detal_G(kcal/mole)
1 gb -46.7059
03/10/2024 21:23:19 PM - INFO - Clean the results.

Results: Energy.csv Dec.csv
Frames mode detal_G(kcal/mole)
1 gb -48.0356
11%|████▊ | 4/37 [02:31<15:15, 27.75s/it]03/10/2024 21:23:20 PM - INFO - Clean the results.

Results: Energy.csv Dec.csv
Frames mode detal_G(kcal/mole)
1 gb -54.4227
03/10/2024 21:23:24 PM - INFO - Clean the results.

Results: Energy.csv Dec.csv
Frames mode detal_G(kcal/mole)
1 gb -50.6699
49%|████████████████████▉ | 18/37 [02:36<01:12, 3.80s/it]03/10/2024 21:23:27 PM - INFO - Clean the results.

Results: Energy.csv Dec.csv
Frames mode detal_G(kcal/mole)
1 gb -38.8843
03/10/2024 21:23:30 PM - INFO - Clean the results.
03/10/2024 21:23:30 PM - INFO - Clean the results.

Results: Energy.csv Dec.csv
Frames mode detal_G(kcal/mole)
1 gb -50.5240

Results: Energy.csv Dec.csv
Frames mode detal_G(kcal/mole)
1 gb -45.4994
03/10/2024 21:23:32 PM - INFO - Clean the results.

Results: Energy.csv Dec.csv
Frames mode detal_G(kcal/mole)
1 gb -54.2276
51%|██████████████████████ | 19/37 [02:44<01:14, 4.13s/it]03/10/2024 21:23:35 PM - INFO - Clean the results.

Results: Energy.csv Dec.csv
Frames mode detal_G(kcal/mole)
1 gb -41.1716
70%|██████████████████████████████▏ | 26/37 [02:46<00:26, 2.43s/it]03/10/2024 21:23:36 PM - INFO - Clean the results.

Results: Energy.csv Dec.csv
Frames mode detal_G(kcal/mole)
1 gb -50.1121
03/10/2024 21:23:38 PM - INFO - Clean the results.

Results: Energy.csv Dec.csv
Frames mode detal_G(kcal/mole)
1 gb -39.9678

@Aunity
Copy link
Collaborator

Aunity commented Mar 12, 2024

Could you upload your input files? It seems your ligands have some problems.

@Tangbbmc
Copy link
Author

Tangbbmc commented Mar 12, 2024

@Aunity > Could you upload your input files? It seems your ligands have some problems.
Ok. I have uploaded partial ligand files. Please help me to check them! Thank you! I am looking forward to your reply as soon as possible!

Ligands_error.zip

@Aunity
Copy link
Collaborator

Aunity commented Mar 14, 2024

Your ligand files need to add hydrogens before run the unigbsa. And you can use the command of unigbsa-validate to check and repair your ligand files.

@Tangbbmc
Copy link
Author

Tangbbmc commented Mar 14, 2024 via email

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

No branches or pull requests

2 participants