Comments
For the Energiemanager, see https://emsesp.org/Troubleshooting/#im-missing-certain-data-from-an-ems-device . Basically turn on logging to ALL or DEBUG (either in the telnet console or the webUI), play around with the energiemanager and see if you can capture which telegrams it is sending and the BUS ID, if any, it's using. |
see also #1717 Seems we have 0x04AA, offset 0 for current power consumption and 0x04A7, offset 0 for the power limit. Maybe there are more values or settings. |
Hi Michael,
Thanks...
Confirm for my WLW186:
* actual power consumption:
power
0x08
0x4AA
0
UINT16
* cooling energy consumption
cool_cons
0x08
0x4AF
40
UINT32
* cooling energy produced
cool_prod
0x08
0x4AE
20
UINT32
* compressor rpm...? what is the scaling...?
comp_rpm
0x08
0x48D
17
INT16
* Absent mode
absent
0x10
0x16E
0
INT8
* dhw actual active mode (0-off, 1-eco, 2-comfort, 3-eco+)
ww
0x10
0x31D
8
UINT8
I will monitore the power limit at 0x04A7, offset 0, but actually is 0 even the hp already started dhw increase...?
btw: Do you know the adress for the system pressure? Is it also available with more then 1 digit...?
Thanks, Ulf
Message ID: ***@***.***>
|
Hi Proddy,
There is nothing to play with at the Buderus MyEnergyMaster, it works very much as a "blackbox"...
Anyhow please find attached my config and a log file during a time where the dhw was increased by the EnergyMaster and cooling was running, both based on PV surplus...
Hope that helps somehow to get more inside to the EnergyMaster...
Please note that 04A7 offset 0 has only shown 0 during the entire day. That was suspected as powerlimit, but not changed at all on my HP WLW186...
Thanks and regards,
Ulf
…------------------
Ulf Hirsekorn
------------------
________________________________
Von: Proddy ***@***.***>
Gesendet: Montag, August 19, 2024 8:29 PM
An: emsesp/EMS-ESP32 ***@***.***>
Cc: UlfHRO ***@***.***>; Author ***@***.***>
Betreff: Re: [emsesp/EMS-ESP32] Heatpump with BC400/RC220 DHW mode and Energiemanager (Issue #1957)
For the Energiemanager, see https://emsesp.org/Troubleshooting/#im-missing-certain-data-from-an-ems-device . Basically turn on logging to ALL or DEBUG (either in the telnet console or the webUI), play around with the energiemanager and see if you can capture which telegrams it is sending and the BUS ID, if any, it's using.
—
Reply to this email directly, view it on GitHub<#1957 (comment)>, or unsubscribe<https://github.com/notifications/unsubscribe-auth/BCGDZ74WSUE77HJZWR4FDETZSI2SHAVCNFSM6AAAAABMXWUYE2VHI2DSMVQWIX3LMV43OSLTON2WKQ3PNVWWK3TUHMZDEOJXGE4DGOBYG4>.
You are receiving this because you authored the thread.Message ID: ***@***.***>
{
"system": {
"version": "3.7.0-dev.30",
"uptime": "003+08:18:17.110",
"uptimeSec": 289097,
"platform": "ESP32",
"arduino": "Tasmota Arduino v2.0.17",
"sdk": "4.4.8.240628",
"freeMem": 133,
"maxAlloc": 51,
"freeCaps": 84,
"usedApp": 1690,
"freeApp": 870,
"partition": "boot",
"resetReason": "Software reset CPU / Software reset CPU"
},
"network": {
"network": "WiFi",
"hostname": "ems-esp",
"RSSI": -61,
"TxPowerSetting": 0,
"staticIP": false,
"lowBandwidth": false,
"disableSleep": true,
"enableMDNS": true,
"enableCORS": false,
"APProvisionMode": "disconnected",
"APSecurity": "wpa2",
"APSSID": "ems-esp"
},
"ntp": {
"NTPStatus": "connected",
"enabled": true,
"server": "time.google.com",
"tzLabel": "Europe/Amsterdam"
},
"mqtt": {
"MQTTStatus": "disconnected",
"enabled": false,
"clientID": "esp32-5ae2dec4",
"keepAlive": 60,
"cleanSession": true,
"entityFormat": 0,
"base": "ems-esp",
"discoveryPrefix": "homeassistant",
"discoveryType": 0,
"nestedFormat": 2,
"haEnabled": false,
"mqttQos": 0,
"mqttRetain": false,
"publishTimeHeartbeat": 60,
"publishTimeBoiler": 10,
"publishTimeThermostat": 10,
"publishTimeSolar": 10,
"publishTimeMixer": 10,
"publishTimeWater": 10,
"publishTimeOther": 60,
"publishTimeSensor": 10,
"publishSingle": false,
"publish2command": false,
"sendResponse": false
},
"syslog": {
"enabled": false
},
"sensor": {
"temperatureSensors": 0,
"temperatureSensorReads": 0,
"temperatureSensorFails": 0
},
"api": {
"APICalls": 185024,
"APIFails": 1
},
"bus": {
"busStatus": "connected",
"busProtocol": "Buderus",
"busTelegramsReceived": 1429121,
"busReads": 233460,
"busWrites": 147,
"busIncompleteTelegrams": 21,
"busReadsFailed": 0,
"busWritesFailed": 0,
"busRxLineQuality": 100,
"busTxLineQuality": 100
},
"settings": {
"boardProfile": "S32",
"locale": "en",
"txMode": 1,
"emsBusID": 11,
"showerTimer": false,
"showerMinDuration": 180,
"showerAlert": false,
"hideLed": false,
"noTokenApi": false,
"readonlyMode": false,
"fahrenheit": false,
"dallasParasite": false,
"boolFormat": 6,
"boolDashboard": 1,
"enumFormat": 1,
"analogEnabled": false,
"telnetEnabled": false,
"maxWebLogBuffer": 100,
"webLogBuffer": 0,
"modbusEnabled": false
},
"devices": [
{
"type": "boiler",
"name": "CS6800i/WLW176i",
"deviceID": "0x08",
"productID": 8,
"brand": "Buderus",
"version": "00.00",
"entities": 161,
"handlersReceived": "0xBF 0x14 0xD1 0xE3 0xE4 0xE5 0xE9 0x0494 0x0495 0x048F",
"handlersFetched": "0xE6 0xEA 0x048D 0x04A2 0x0485 0x0486 0x0492 0x0488 0x0484 0x048B 0x0491 0x0499 0x049C 0x049D 0x04AE 0x04AF 0x02CC",
"handlersPending": "0x10 0x11 0xC2 0x15 0x1C 0x18 0x19 0x1A 0x35 0x16 0x33 0x34 0x26 0x2A 0x28 0x048A 0x04A5",
"handlersIgnored": "0x04CA 0x04CB 0x04C0 0x02EA 0xE7 0x04F2 0x061E 0x04A7 0x023E 0x0240 0x0291 0x0292 0x0293 0x0294 0x029B 0x02A5 0x02F5 0x02D6 0x04A8 0x04A9 0x04AA 0x04AB 0x04AC 0x0497 0xF7 0x04A0 0x17 0x02E0 0xF6"
},
{
"type": "thermostat",
"name": "Rego 3000/UI800/WSW196i/BC400",
"deviceID": "0x10",
"productID": 253,
"brand": "",
"version": "47.10",
"entities": 71,
"handlersReceived": "0x06 0x02BA 0x02BB 0x02BC 0x031D 0x0267",
"handlersFetched": "0x02A5 0x02B9 0x02AF 0x029B 0x0471 0x02CC 0x0467 0x0291 0x0292 0x0293 0x0294 0x02F5 0x023A 0x0240 0xBB 0x023E",
"handlersPending": "0xA3 0xA2 0x12 0x13 0x02A6 0x02B0 0x029C 0x0472 0x02A7 0x02B1 0x029D 0x0473 0x02A8 0x02B2 0x029E 0x0474 0x02A9 0x02BD 0x02B3 0x029F 0x0475 0x02AA 0x02BE 0x02B4 0x02A0 0x0476 0x02AB 0x02BF 0x02B5 0x02A1 0x0477 0x02AC 0x02C0 0x02B6 0x02A2 0x0478 0x02CE 0x0468 0x02D0 0x0469 0x02D2 0x046A 0x02F6 0x031B 0x031E 0x0269",
"handlersIgnored": "0x0507 0x0508 0x0509 0x050A 0x059D 0xBF 0xF7 0xF9 0x016E 0x08"
},
{
"type": "thermostat",
"name": "RT800/RC220",
"deviceID": "0x38",
"productID": 3,
"brand": "",
"version": "21.04",
"entities": 3,
"handlersReceived": "0x042B 0x047B",
"handlersPending": "0x0273 0x0A6A",
"handlersIgnored": "0xBF"
},
{
"type": "gateway",
"name": "WiFi module",
"deviceID": "0x48",
"productID": 252,
"brand": "Buderus",
"version": "08.02",
"entities": 0,
"handlersIgnored": "0xF9 0x2040 0x0495 0x0494 0x04AF 0x04AE 0xF7 0x0DE8 0x0DE9 0x0DEA 0x0DEC 0x0DED 0x0DEF 0x0DF0 0x0DF1 0x016E 0x04A7"
}
]
}
2024-08-20 16:52:21.007 WARNING 2800: [telegram] Incomplete Rx: B8 00 38 00 88 00 08 00 FF 16 03 8D 1C E6
2024-08-20 16:52:21.227 TRACE 2801: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3B (offset 9)
2024-08-20 16:52:21.398 TRACE 2802: [emsesp] boiler(0x08) -B-> All(0x00), HpPower(0x048D), data: 1C (offset 22)
2024-08-20 16:52:21.622 TRACE 2803: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3C (offset 9)
2024-08-20 16:52:21.906 TRACE 2804: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3D (offset 9)
2024-08-20 16:52:22.289 TRACE 2805: [emsesp] boiler(0x08) -B-> All(0x00), HpPower(0x048D), data: 1B (offset 22)
2024-08-20 16:52:22.460 TRACE 2806: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3E (offset 9)
2024-08-20 16:52:22.875 TRACE 2807: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3F (offset 9)
2024-08-20 16:52:23.046 TRACE 2808: [emsesp] boiler(0x08) -B-> All(0x00), HpPower(0x048D), data: 1C (offset 22)
2024-08-20 16:52:23.800 TRACE 2809: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 40 (offset 9)
2024-08-20 16:52:24.477 TRACE 2810: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 41 (offset 9)
2024-08-20 16:52:24.700 TRACE 2811: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 42 (offset 9)
2024-08-20 16:52:24.872 TRACE 2812: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 43 (offset 9)
2024-08-20 16:52:25.107 TRACE 2813: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorSlowPlus2(0xE3), data: 00 00 10 00 00 00 00 00 00 00 00 00 B4 00 00 00 00 00 00 00
2024-08-20 16:52:25.279 TRACE 2814: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 44 (offset 9)
2024-08-20 16:52:25.470 TRACE 2815: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorFastPlus(0xE4), data: 13 00 B4 00 19 01 00 00 00 00 00 00 D0 00 00 0F 00 00 B4 (offset 6)
2024-08-20 16:52:25.652 TRACE 2816: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorFastPlus(0xE4), data: 04 3B (offset 36)
2024-08-20 16:52:25.824 TRACE 2817: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 46 (offset 9)
2024-08-20 16:52:25.996 TRACE 2818: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 48 (offset 9)
2024-08-20 16:52:26.212 TRACE 2819: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 49 (offset 9)
2024-08-20 16:52:26.385 TRACE 2820: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 4A (offset 9)
2024-08-20 16:52:26.504 TRACE 2821: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 4B (offset 9)
2024-08-20 16:52:26.504 TRACE 2822: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorWWPlus(0xE9), data: 3C 02 5C 02 56 00 00 00 00 3E 3C 00 00 00 00 00 00 00 00 00 00 00 00 3C
2024-08-20 16:52:27.094 TRACE 2823: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 4A (offset 9)
2024-08-20 16:52:27.564 TRACE 2824: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 49 (offset 9)
2024-08-20 16:52:27.883 TRACE 2825: [emsesp] gateway(0x48) -W-> boiler(0x08), ?(0x04A7), data: 02 73 (offset 4)
2024-08-20 16:52:27.888 TRACE 2826: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 48 (offset 9)
2024-08-20 16:52:28.080 TRACE 2827: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 47 (offset 9)
2024-08-20 16:52:28.253 TRACE 2828: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 46 (offset 9)
2024-08-20 16:52:28.460 TRACE 2829: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 44 (offset 9)
2024-08-20 16:52:28.688 TRACE 2830: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 43 (offset 9)
2024-08-20 16:52:28.860 TRACE 2831: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 42 (offset 9)
2024-08-20 16:52:29.086 TRACE 2832: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 41 (offset 9)
2024-08-20 16:52:29.259 TRACE 2833: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3F (offset 9)
2024-08-20 16:52:29.430 TRACE 2834: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3E (offset 9)
2024-08-20 16:52:29.654 TRACE 2835: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3D (offset 9)
2024-08-20 16:52:29.978 TRACE 2836: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3C (offset 9)
2024-08-20 16:52:30.149 TRACE 2837: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3B (offset 9)
2024-08-20 16:52:30.476 TRACE 2838: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3A (offset 9)
2024-08-20 16:52:30.966 TRACE 2839: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3B (offset 9)
2024-08-20 16:52:31.284 TRACE 2840: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3C (offset 9)
2024-08-20 16:52:31.666 TRACE 2841: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3D (offset 9)
2024-08-20 16:52:32.090 TRACE 2842: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3E (offset 9)
2024-08-20 16:52:32.699 TRACE 2843: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3F (offset 9)
2024-08-20 16:52:32.963 TRACE 2844: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3E (offset 9)
2024-08-20 16:52:33.393 TRACE 2845: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3F (offset 9)
2024-08-20 16:52:33.876 TRACE 2846: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3E (offset 9)
2024-08-20 16:52:34.102 TRACE 2847: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3F (offset 9)
2024-08-20 16:52:34.894 TRACE 2848: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 40 (offset 9)
2024-08-20 16:52:35.066 TRACE 2849: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3F (offset 9)
2024-08-20 16:52:35.258 TRACE 2850: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorSlowPlus2(0xE3), data: 00 00 10 00 00 00 00 00 00 00 00 00 B4 00 00 00 00 00 00 00
2024-08-20 16:52:35.484 TRACE 2851: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3E (offset 9)
2024-08-20 16:52:35.673 TRACE 2852: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorFastPlus(0xE4), data: 13 00 B4 00 19 01 00 00 00 00 00 00 D0 00 00 0F 00 00 B4 (offset 6)
2024-08-20 16:52:35.844 TRACE 2853: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorFastPlus(0xE4), data: 04 38 (offset 36)
2024-08-20 16:52:36.070 TRACE 2854: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3B (offset 9)
2024-08-20 16:52:36.242 TRACE 2855: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3A (offset 9)
2024-08-20 16:52:36.437 TRACE 2856: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorWWPlus(0xE9), data: 3C 02 5C 02 56 00 00 00 00 3E 3C 00 00 00 00 00 00 00 00 00 00 00 00 3C
2024-08-20 16:52:36.964 TRACE 2857: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 39 (offset 9)
2024-08-20 16:52:37.204 TRACE 2858: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3A (offset 9)
2024-08-20 16:52:37.476 TRACE 2859: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3B (offset 9)
2024-08-20 16:52:37.758 TRACE 2860: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3C (offset 9)
2024-08-20 16:52:38.078 TRACE 2861: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3D (offset 9)
2024-08-20 16:52:38.460 TRACE 2862: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3E (offset 9)
2024-08-20 16:52:38.632 TRACE 2863: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3F (offset 9)
2024-08-20 16:52:38.804 TRACE 2864: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 40 (offset 9)
2024-08-20 16:52:39.028 TRACE 2865: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 41 (offset 9)
2024-08-20 16:52:39.200 TRACE 2866: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 42 (offset 9)
2024-08-20 16:52:39.372 TRACE 2867: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 43 (offset 9)
2024-08-20 16:52:39.591 TRACE 2868: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 44 (offset 9)
2024-08-20 16:52:39.869 TRACE 2869: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 45 (offset 9)
2024-08-20 16:52:40.196 TRACE 2870: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 46 (offset 9)
2024-08-20 16:52:40.477 TRACE 2871: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 45 (offset 9)
2024-08-20 16:52:40.701 TRACE 2872: [emsesp] thermostat(0x38) -W-> thermostat(0x10), RemoteHumidity(0x047B), data: 10 34 00 A0
2024-08-20 16:52:40.893 TRACE 2873: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 46 (offset 9)
2024-08-20 16:52:41.064 TRACE 2874: [emsesp] boiler(0x08) -B-> All(0x00), HpTemperatures(0x048F), data: 01 68 (offset 28)
2024-08-20 16:52:41.363 TRACE 2875: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 45 (offset 9)
2024-08-20 16:52:41.506 TRACE 2876: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 44 (offset 9)
2024-08-20 16:52:41.506 TRACE 2877: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 43 (offset 9)
2024-08-20 16:52:41.957 TRACE 2878: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 42 (offset 9)
2024-08-20 16:52:42.132 TRACE 2879: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 41 (offset 9)
2024-08-20 16:52:42.196 TRACE 2880: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 40 (offset 9)
2024-08-20 16:52:42.512 TRACE 2881: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3F (offset 9)
2024-08-20 16:52:42.795 TRACE 2882: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3E (offset 9)
2024-08-20 16:52:43.069 TRACE 2883: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3D (offset 9)
2024-08-20 16:52:43.242 TRACE 2884: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3C (offset 9)
2024-08-20 16:52:43.529 TRACE 2885: [emsesp] gateway(0x48) -R-> thermostat(0x10), ValueConfig(0xF9), length: 17, data: FF 01 B0 08
2024-08-20 16:52:43.591 TRACE 2886: [emsesp] thermostat(0x10) -W-> gateway(0x48), ValueConfig(0xF9), data: FF 01 B0 08 0B 00 00 00 16 00 00 00 19 00 00 00 23 00 00 00 19
2024-08-20 16:52:43.597 TRACE 2887: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3B (offset 9)
2024-08-20 16:52:44.191 TRACE 2888: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3A (offset 9)
2024-08-20 16:52:44.570 TRACE 2889: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 39 (offset 9)
2024-08-20 16:52:44.897 TRACE 2890: [emsesp] boiler(0x08) -B-> All(0x00), HpTemperatures(0x048F), data: 00 41 (offset 16)
2024-08-20 16:52:45.068 TRACE 2891: [emsesp] boiler(0x08) -R-> thermostat(0x10), PVSettings(0x023E), length: 1
2024-08-20 16:52:45.090 TRACE 2892: [emsesp] thermostat(0x10) -W-> boiler(0x08), PVSettings(0x023E), data: 02
2024-08-20 16:52:45.101 TRACE 2893: [emsesp] boiler(0x08) -R-> thermostat(0x10), PVSettings(0x023E), length: 1 (offset 3)
2024-08-20 16:52:45.124 TRACE 2894: [emsesp] thermostat(0x10) -W-> boiler(0x08), PVSettings(0x023E), data: 00 (offset 3)
2024-08-20 16:52:45.127 TRACE 2895: [emsesp] boiler(0x08) -R-> thermostat(0x10), PVSettings(0x023E), length: 1 (offset 5)
2024-08-20 16:52:45.157 TRACE 2896: [emsesp] thermostat(0x10) -W-> boiler(0x08), PVSettings(0x023E), data: 00 (offset 5)
2024-08-20 16:52:45.161 TRACE 2897: [emsesp] boiler(0x08) -R-> thermostat(0x10), RC300Settings(0x0240), length: 1 (offset 10)
2024-08-20 16:52:45.176 TRACE 2898: [emsesp] thermostat(0x10) -W-> boiler(0x08), RC300Settings(0x0240), data: F4 (offset 10)
2024-08-20 16:52:45.194 TRACE 2899: [emsesp] boiler(0x08) -R-> thermostat(0x10), RC300Settings(0x0240), length: 1 (offset 12)
2024-08-20 16:52:45.209 TRACE 2900: [emsesp] thermostat(0x10) -W-> boiler(0x08), RC300Settings(0x0240), data: FF (offset 12)
2024-08-20 16:52:45.228 TRACE 2901: [emsesp] boiler(0x08) -R-> thermostat(0x10), RC300Settings(0x0240), length: 1 (offset 24)
2024-08-20 16:52:45.242 TRACE 2902: [emsesp] thermostat(0x10) -W-> boiler(0x08), RC300Settings(0x0240), data: FF (offset 24)
2024-08-20 16:52:45.261 TRACE 2903: [emsesp] boiler(0x08) -R-> thermostat(0x10), HPMode(0x0291), length: 1
2024-08-20 16:52:45.290 TRACE 2904: [emsesp] thermostat(0x10) -W-> boiler(0x08), HPMode(0x0291), data: 01
2024-08-20 16:52:45.301 TRACE 2905: [emsesp] boiler(0x08) -R-> thermostat(0x10), HPMode(0x0291), length: 1 (offset 5)
2024-08-20 16:52:45.323 TRACE 2906: [emsesp] thermostat(0x10) -W-> boiler(0x08), HPMode(0x0291), data: 02 (offset 5)
2024-08-20 16:52:45.327 TRACE 2907: [emsesp] boiler(0x08) -R-> thermostat(0x10), HPMode(0x0292), length: 1
2024-08-20 16:52:45.357 TRACE 2908: [emsesp] thermostat(0x10) -W-> boiler(0x08), HPMode(0x0292), data: 00
2024-08-20 16:52:45.367 TRACE 2909: [emsesp] boiler(0x08) -R-> thermostat(0x10), HPMode(0x0292), length: 1 (offset 5)
2024-08-20 16:52:45.389 TRACE 2910: [emsesp] thermostat(0x10) -W-> boiler(0x08), HPMode(0x0292), data: 00 (offset 5)
2024-08-20 16:52:45.454 TRACE 2911: [emsesp] boiler(0x08) -R-> thermostat(0x10), HPMode(0x0293), length: 1
2024-08-20 16:52:45.477 TRACE 2912: [emsesp] thermostat(0x10) -W-> boiler(0x08), HPMode(0x0293), data: 00
2024-08-20 16:52:45.487 TRACE 2913: [emsesp] boiler(0x08) -R-> thermostat(0x10), HPMode(0x0293), length: 1 (offset 5)
2024-08-20 16:52:45.504 TRACE 2914: [emsesp] thermostat(0x10) -W-> boiler(0x08), HPMode(0x0293), data: 00 (offset 5)
2024-08-20 16:52:45.514 TRACE 2915: [emsesp] boiler(0x08) -R-> thermostat(0x10), HPMode(0x0294), length: 1
2024-08-20 16:52:45.544 TRACE 2916: [emsesp] thermostat(0x10) -W-> boiler(0x08), HPMode(0x0294), data: 00
2024-08-20 16:52:45.554 TRACE 2917: [emsesp] boiler(0x08) -R-> thermostat(0x10), HPMode(0x0294), length: 1 (offset 5)
2024-08-20 16:52:45.576 TRACE 2918: [emsesp] thermostat(0x10) -W-> boiler(0x08), HPMode(0x0294), data: 00 (offset 5)
2024-08-20 16:52:45.580 TRACE 2919: [emsesp] boiler(0x08) -R-> thermostat(0x10), RC300Curves(0x029B), length: 1 (offset 1)
2024-08-20 16:52:45.607 TRACE 2920: [emsesp] thermostat(0x10) -W-> boiler(0x08), RC300Curves(0x029B), data: 03 (offset 1)
2024-08-20 16:52:45.632 TRACE 2921: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 01 00 00 00 00 00 00 00 00 04 38
2024-08-20 16:52:45.824 TRACE 2922: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorSlowPlus2(0xE3), data: 00 00 10 00 00 00 00 00 00 00 00 00 B4 00 00 00 00 00 00 00
2024-08-20 16:52:46.079 TRACE 2923: [emsesp] gateway(0x48) -R-> thermostat(0x10), ValueConfig(0xF9), length: 17, data: FF 01 B1 08
2024-08-20 16:52:46.144 TRACE 2924: [emsesp] thermostat(0x10) -W-> gateway(0x48), ValueConfig(0xF9), data: FF 01 B1 08 0B 00 00 00 16 00 00 00 19 00 00 00 23 00 00 00 19
2024-08-20 16:52:46.167 TRACE 2925: [emsesp] boiler(0x08) -R-> thermostat(0x10), RC300Curves(0x029B), length: 2 (offset 7)
2024-08-20 16:52:46.193 TRACE 2926: [emsesp] thermostat(0x10) -W-> boiler(0x08), RC300Curves(0x029B), data: 37 1E (offset 7)
2024-08-20 16:52:46.197 TRACE 2927: [emsesp] boiler(0x08) -R-> thermostat(0x10), RC300Monitor(0x02A5), length: 1 (offset 17)
2024-08-20 16:52:46.223 TRACE 2928: [emsesp] thermostat(0x10) -W-> boiler(0x08), RC300Monitor(0x02A5), data: 00 (offset 17)
2024-08-20 16:52:46.236 TRACE 2929: [emsesp] boiler(0x08) -R-> thermostat(0x10), RC300Monitor(0x02A6), length: 1 (offset 17)
2024-08-20 16:52:46.250 TRACE 2930: [emsesp] thermostat(0x10) -W-> boiler(0x08), RC300Monitor(0x02A6), data: <empty> (offset 17)
2024-08-20 16:52:46.263 TRACE 2931: [emsesp] boiler(0x08) -R-> thermostat(0x10), RC300Monitor(0x02A7), length: 1 (offset 17)
2024-08-20 16:52:46.284 TRACE 2932: [emsesp] thermostat(0x10) -W-> boiler(0x08), RC300Monitor(0x02A7), data: <empty> (offset 17)
2024-08-20 16:52:46.298 TRACE 2933: [emsesp] boiler(0x08) -R-> thermostat(0x10), RC300Monitor(0x02A8), length: 1 (offset 17)
2024-08-20 16:52:46.316 TRACE 2934: [emsesp] thermostat(0x10) -W-> boiler(0x08), RC300Monitor(0x02A8), data: <empty> (offset 17)
2024-08-20 16:52:46.331 TRACE 2935: [emsesp] boiler(0x08) -R-> thermostat(0x10), RC300WWmode(0x02F5), length: 1
2024-08-20 16:52:46.350 TRACE 2936: [emsesp] thermostat(0x10) -W-> boiler(0x08), RC300WWmode(0x02F5), data: 01
2024-08-20 16:52:46.364 TRACE 2937: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 37 (offset 9)
2024-08-20 16:52:46.556 TRACE 2938: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorFastPlus(0xE4), data: 13 00 B4 00 19 01 00 00 00 00 00 00 D0 00 00 0F 00 00 B4 (offset 6)
2024-08-20 16:52:46.732 TRACE 2939: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorFastPlus(0xE4), data: 04 37 (offset 36)
2024-08-20 16:52:46.927 TRACE 2940: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorWWPlus(0xE9), data: 3C 02 5C 02 56 00 00 00 00 3E 3C 00 00 00 00 00 00 00 00 00 00 00 00 3C
2024-08-20 16:52:47.113 TRACE 2941: [emsesp] boiler(0x08) -B-> All(0x00), UBADevices(0x07), data: 09 01 00 00 00 00 01 00 01 00 00 00 00 00 00
2024-08-20 16:52:47.325 TRACE 2942: [emsesp] boiler(0x08) -B-> All(0x00), UBAOutdoorTemp(0xD1), data: 01 0D 00
2024-08-20 16:52:47.522 TRACE 2943: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorSlowPlus(0xE5), data: 20 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 39 00 (offset 2)
2024-08-20 16:52:47.721 TRACE 2944: [emsesp] boiler(0x08) -B-> All(0x00), HpTemperatures(0x048F), data: 02 18 00 C1 00 B4 00 D0 00 00 00 00 01 0A 01 F0 00 42 01 62 00 A1 00 FF
2024-08-20 16:52:47.955 TRACE 2945: [emsesp] thermostat(0x10) -B-> All(0x00), SystemError(0xBF), data: 10 FD 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
2024-08-20 16:52:48.198 TRACE 2946: [emsesp] boiler(0x08) -B-> All(0x00), HpTemperatures(0x048F), data: 02 56 00 38 01 67 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 (offset 24)
2024-08-20 16:52:48.395 TRACE 2947: [emsesp] boiler(0x08) -B-> All(0x00), UBAEnergySupplied(0x0494), data: 00 93 AF 2C 00 00 05 BA 00 00 04 56 00 00 00 6C 00 00 00 F7 00 00 00 00
2024-08-20 16:52:48.568 TRACE 2948: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 36 (offset 9)
2024-08-20 16:52:48.805 TRACE 2949: [emsesp] gateway(0x48) -R-> thermostat(0x10), ValueConfig(0xF9), length: 17, data: FF 01 B2 08
2024-08-20 16:52:48.867 TRACE 2950: [emsesp] thermostat(0x10) -W-> gateway(0x48), ValueConfig(0xF9), data: FF 01 B2 08 0B 00 00 00 16 00 00 00 19 00 00 00 23 00 00 00 19
2024-08-20 16:52:48.915 TRACE 2951: [emsesp] boiler(0x08) -B-> All(0x00), UBAInformation(0x0495), data: 00 13 CE B4 00 0E 3E 1D 00 01 A5 A0 00 00 00 00 00 03 EA ED 00 00 02 8E
2024-08-20 16:52:49.113 TRACE 2952: [emsesp] boiler(0x08) -B-> All(0x00), UBAInformation(0x0495), data: 00 00 02 2F 00 00 00 2A 00 00 00 00 00 00 00 35 00 00 00 13 00 00 00 04 (offset 24)
2024-08-20 16:52:49.311 TRACE 2953: [emsesp] boiler(0x08) -B-> All(0x00), UBAInformation(0x0495), data: 00 00 00 0E 00 00 00 00 00 00 01 EC 00 00 00 00 00 00 02 00 00 00 00 3E (offset 48)
2024-08-20 16:52:49.539 TRACE 2954: [emsesp] boiler(0x08) -B-> All(0x00), UBAInformation(0x0495), data: 00 00 01 6E 00 00 00 3F 00 00 00 00 (offset 72)
2024-08-20 16:52:49.722 TRACE 2955: [emsesp] boiler(0x08) -B-> All(0x00), HpInput(0x04A2), data: 12 00 00 00 00 00 00 00 01 00
2024-08-20 16:52:49.899 TRACE 2956: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x04A8), data: 00 B4 00 00 00 B4 (offset 1)
2024-08-20 16:52:50.083 TRACE 2957: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 37 (offset 9)
2024-08-20 16:52:50.261 TRACE 2958: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x04A9), data: 00 01 2C 02 58 03 84
2024-08-20 16:52:50.443 TRACE 2959: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x04AA), data: 02 4F 00 00 0B 54 01 4B 02 74
2024-08-20 16:52:50.660 TRACE 2960: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 36 (offset 9)
2024-08-20 16:52:50.842 TRACE 2961: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x04AB), data: 00 00 00 00 23 28 00 00 00 00
2024-08-20 16:52:51.013 TRACE 2962: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 35 (offset 9)
2024-08-20 16:52:51.252 TRACE 2963: [emsesp] thermostat(0x38) -W-> thermostat(0x10), RemoteTemp(0x042B), data: 01 0D 0A 7F 01 01
2024-08-20 16:52:51.280 TRACE 2964: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 34 (offset 9)
2024-08-20 16:52:51.454 TRACE 2965: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x04AC), data: 01 00 00
2024-08-20 16:52:51.626 TRACE 2966: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 33 (offset 9)
2024-08-20 16:52:51.866 TRACE 2967: [emsesp] boiler(0x08) -B-> All(0x00), HPEnergy(0x04AE), data: 00 02 3C EA 00 00 2A 6E 00 00 00 04 00 01 B1 B4 00 00 00 62 00 00 60 C7
2024-08-20 16:52:52.045 TRACE 2968: [emsesp] boiler(0x08) -B-> All(0x00), HPEnergy(0x04AE), data: 00 00 00 00 00 00 00 00 (offset 24)
2024-08-20 16:52:52.217 TRACE 2969: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 32 (offset 9)
2024-08-20 16:52:52.396 TRACE 2970: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 31 (offset 9)
2024-08-20 16:52:52.593 TRACE 2971: [emsesp] boiler(0x08) -B-> All(0x00), HPMeters(0x04AF), data: 00 00 C8 0F 00 00 C0 8F 00 00 07 80 00 00 04 7A 00 00 01 B1 00 00 14 10
2024-08-20 16:52:52.791 TRACE 2972: [emsesp] boiler(0x08) -B-> All(0x00), HPMeters(0x04AF), data: 00 00 18 99 00 00 05 9B 00 00 8F 17 00 00 01 E5 00 00 18 DD 00 00 00 00 (offset 24)
2024-08-20 16:52:53.011 TRACE 2973: [emsesp] Me(0x0B) -R-> boiler(0x08), UBAParametersPlus(0xE6), length: 255
2024-08-20 16:52:53.048 TRACE 2974: [emsesp] boiler(0x08) -W-> Me(0x0B), UBAParametersPlus(0xE6), data: 01 1E 00 00 00 00 00 00 00 00 00 01 00 00 00 00 00 00 00 00 02 00 00 00 01
2024-08-20 16:52:53.048 TRACE 2975: [emsesp] Me(0x0B) -R-> boiler(0x08), UBAParameterWWPlus(0xEA), length: 255
2024-08-20 16:52:53.097 TRACE 2976: [emsesp] boiler(0x08) -W-> Me(0x0B), UBAParameterWWPlus(0xEA), data: 01 2D 00 00 00 01 03 3E 00 00 18 37 3C 2A 00 00 00 00 00 00 00 00 2D (offset 5)
2024-08-20 16:52:53.134 TRACE 2977: [emsesp] boiler(0x08) -B-> All(0x00), HPMeters(0x04AF), data: 00 00 00 00 00 00 00 00 (offset 48)
2024-08-20 16:52:53.306 TRACE 2978: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 30 (offset 9)
2024-08-20 16:52:53.505 TRACE 2979: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x04CA), data: 1E 03 1B 58 0F 00 02 F3 03 20 02 55 FF FF 00 00 FF FF FF 00 00 FF 00 00 00
2024-08-20 16:52:53.768 TRACE 2980: [emsesp] thermostat(0x38) -B-> All(0x00), SystemError(0xBF), data: 38 03 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
2024-08-20 16:52:53.956 TRACE 2981: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x04CA), data: 00 00 FF FF 00 00 FF 03 (offset 25)
2024-08-20 16:52:54.128 TRACE 2982: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 2F (offset 9)
2024-08-20 16:52:54.304 TRACE 2983: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x04CB), data: 00 00 00 00
2024-08-20 16:52:54.536 TRACE 2984: [emsesp] gateway(0x48) -R-> thermostat(0x10), ValueConfig(0xF9), length: 17, data: FF 01 B0 05
2024-08-20 16:52:54.598 TRACE 2985: [emsesp] thermostat(0x10) -W-> gateway(0x48), ValueConfig(0xF9), data: FF 01 B0 05 0B 00 00 00 1E 00 00 00 23 00 00 00 3C 00 00 00 23
2024-08-20 16:52:54.662 TRACE 2986: [emsesp] Me(0x0B) -R-> boiler(0x08), UBAParameterWWPlus(0xEA), length: 227 (offset 28)
2024-08-20 16:52:54.664 TRACE 2987: [emsesp] boiler(0x08) -W-> Me(0x0B), UBAParameterWWPlus(0xEA), data: <empty> (offset 28)
2024-08-20 16:52:54.664 TRACE 2988: [emsesp] Me(0x0B) -R-> boiler(0x08), HpPower(0x048D), length: 255
2024-08-20 16:52:54.728 TRACE 2989: [emsesp] boiler(0x08) -W-> Me(0x0B), HpPower(0x048D), data: 08 60 10 10 39 00 00 02 00 00 00 05 00 00 00 00 19 19 2F 3B 00 2D 1C E9 2D
2024-08-20 16:52:54.915 TRACE 2990: [emsesp] Me(0x0B) -R-> boiler(0x08), HpPower(0x048D), length: 230 (offset 25)
2024-08-20 16:52:54.919 TRACE 2991: [emsesp] boiler(0x08) -W-> Me(0x0B), HpPower(0x048D), data: 00 2D 00 07 (offset 25)
2024-08-20 16:52:54.919 TRACE 2992: [emsesp] Me(0x0B) -R-> boiler(0x08), HpInput(0x04A2), length: 255
2024-08-20 16:52:54.958 TRACE 2993: [emsesp] boiler(0x08) -W-> Me(0x0B), HpInput(0x04A2), data: 12 00 00 00 00 00 00 00 01 00
2024-08-20 16:52:54.958 TRACE 2994: [emsesp] Me(0x0B) -R-> boiler(0x08), HpCooling(0x0485), length: 255
2024-08-20 16:52:55.026 TRACE 2995: [emsesp] boiler(0x08) -W-> Me(0x0B), HpCooling(0x0485), data: 03 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
2024-08-20 16:52:55.026 TRACE 2996: [emsesp] Me(0x0B) -R-> boiler(0x08), HpInConfig(0x0486), length: 255
2024-08-20 16:52:55.080 TRACE 2997: [emsesp] boiler(0x08) -W-> Me(0x0B), HpInConfig(0x0486), data: 00 01 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 01
2024-08-20 16:52:55.080 TRACE 2998: [emsesp] Me(0x0B) -R-> boiler(0x08), HpHeaterConfig(0x0492), length: 255
2024-08-20 16:52:55.107 TRACE 2999: [emsesp] boiler(0x08) -W-> Me(0x0B), HpHeaterConfig(0x0492), data: 04 00 05 05 05
2024-08-20 16:52:55.107 TRACE 3000: [emsesp] Me(0x0B) -R-> boiler(0x08), HPValve(0x0488), length: 255
2024-08-20 16:52:55.172 TRACE 3001: [emsesp] boiler(0x08) -W-> Me(0x0B), HPValve(0x0488), data: A0 00 00 00 00 00 02 00 00 00 00 13 00 00 00 00 00 00 00 06
2024-08-20 16:52:55.172 TRACE 3002: [emsesp] Me(0x0B) -R-> boiler(0x08), HPSilentMode(0x0484), length: 255
2024-08-20 16:52:55.195 TRACE 3003: [emsesp] boiler(0x08) -W-> Me(0x0B), HPSilentMode(0x0484), data: 01 00 14 1E 04 00 00 00 00 02 01 00 00 00 02
2024-08-20 16:52:55.195 TRACE 3004: [emsesp] Me(0x0B) -R-> boiler(0x08), HPPumps(0x048B), length: 255
2024-08-20 16:52:55.244 TRACE 3005: [emsesp] boiler(0x08) -W-> Me(0x0B), HPPumps(0x048B), data: 1E 2D 00 00 00 00 00 00 00 00 00 00 00 00 00 00 (offset 3)
2024-08-20 16:52:55.325 TRACE 3006: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 31 (offset 9)
2024-08-20 16:52:55.517 TRACE 3007: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorSlowPlus2(0xE3), data: 00 00 10 00 00 00 00 00 00 00 00 00 B4 00 00 00 00 00 00 00
2024-08-20 16:52:55.689 TRACE 3008: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 32 (offset 9)
2024-08-20 16:52:55.931 TRACE 3009: [emsesp] gateway(0x48) -R-> thermostat(0x10), ValueConfig(0xF9), length: 17, data: FF 01 B1 05
2024-08-20 16:52:55.993 TRACE 3010: [emsesp] thermostat(0x10) -W-> gateway(0x48), ValueConfig(0xF9), data: FF 01 B1 05 0B 00 00 00 1E 00 00 00 23 00 00 00 3C 00 00 00 23
2024-08-20 16:52:56.012 TRACE 3011: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 34 (offset 9)
2024-08-20 16:52:56.186 TRACE 3012: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 35 (offset 9)
2024-08-20 16:52:56.358 TRACE 3013: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 36 (offset 9)
2024-08-20 16:52:56.504 TRACE 3014: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 37 (offset 9)
2024-08-20 16:52:56.504 TRACE 3015: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 38 (offset 9)
2024-08-20 16:52:56.908 TRACE 3016: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 39 (offset 9)
2024-08-20 16:52:57.086 TRACE 3017: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3A (offset 9)
2024-08-20 16:52:57.186 TRACE 3018: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorFastPlus(0xE4), data: 13 00 B4 00 19 01 00 00 00 00 00 00 D0 00 00 0F 00 00 B4 (offset 6)
2024-08-20 16:52:57.445 TRACE 3019: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorFastPlus(0xE4), data: 04 38 (offset 36)
2024-08-20 16:52:57.671 TRACE 3020: [emsesp] Me(0x0B) -R-> boiler(0x08), HPPumps(0x048B), length: 236 (offset 19)
2024-08-20 16:52:57.675 TRACE 3021: [emsesp] boiler(0x08) -W-> Me(0x0B), HPPumps(0x048B), data: <empty> (offset 19)
2024-08-20 16:52:57.675 TRACE 3022: [emsesp] Me(0x0B) -R-> boiler(0x08), HPAdditionalHeater(0x0491), length: 255
2024-08-20 16:52:57.730 TRACE 3023: [emsesp] boiler(0x08) -W-> Me(0x0B), HPAdditionalHeater(0x0491), data: 01 00 01 00 00 00 00 00 00 00 00 00 00 00 14 14 00 50
2024-08-20 16:52:57.730 TRACE 3024: [emsesp] Me(0x0B) -R-> boiler(0x08), HPDhwSettings(0x0499), length: 255
2024-08-20 16:52:57.754 TRACE 3025: [emsesp] boiler(0x08) -W-> Me(0x0B), HPDhwSettings(0x0499), data: 01 00 00 00 32 34 34 3C 06 06 06 (offset 4)
2024-08-20 16:52:57.791 TRACE 3026: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3C (offset 9)
2024-08-20 16:52:57.966 TRACE 3027: [emsesp] boiler(0x08) -B-> All(0x00), HpTemperatures(0x048F), data: 01 61 (offset 18)
2024-08-20 16:52:58.138 TRACE 3028: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3B (offset 9)
2024-08-20 16:52:58.385 TRACE 3029: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorWWPlus(0xE9), data: 3C 02 5C 02 56 00 00 00 00 3E 3C 00 00 00 00 00 00 00 00 00 00 00 00 3C
2024-08-20 16:52:58.560 TRACE 3030: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3A (offset 9)
2024-08-20 16:52:58.732 TRACE 3031: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3B (offset 9)
2024-08-20 16:52:58.969 TRACE 3032: [emsesp] gateway(0x48) -R-> thermostat(0x10), ValueConfig(0xF9), length: 17, data: FF 01 B2 05
2024-08-20 16:52:59.031 TRACE 3033: [emsesp] thermostat(0x10) -W-> gateway(0x48), ValueConfig(0xF9), data: FF 01 B2 05 0B 00 00 00 1E 00 00 00 23 00 00 00 3C 00 00 00 23
2024-08-20 16:52:59.063 TRACE 3034: [emsesp] gateway(0x48) -W-> boiler(0x08), ?(0x04A7), data: 02 73 (offset 4)
2024-08-20 16:52:59.134 TRACE 3035: [emsesp] Me(0x0B) -R-> boiler(0x08), HPDhwSettings(0x0499), length: 240 (offset 15)
2024-08-20 16:52:59.136 TRACE 3036: [emsesp] boiler(0x08) -W-> Me(0x0B), HPDhwSettings(0x0499), data: <empty> (offset 15)
2024-08-20 16:52:59.136 TRACE 3037: [emsesp] Me(0x0B) -R-> boiler(0x08), HPSettings2(0x049C), length: 255
2024-08-20 16:52:59.172 TRACE 3038: [emsesp] boiler(0x08) -W-> Me(0x0B), HPSettings2(0x049C), data: 00 00 00 00 00 00 (offset 3)
2024-08-20 16:52:59.192 TRACE 3039: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3A (offset 9)
2024-08-20 16:52:59.538 TRACE 3040: [emsesp] Me(0x0B) -R-> boiler(0x08), HPSettings2(0x049C), length: 246 (offset 9)
2024-08-20 16:52:59.541 TRACE 3041: [emsesp] boiler(0x08) -W-> Me(0x0B), HPSettings2(0x049C), data: <empty> (offset 9)
2024-08-20 16:52:59.541 TRACE 3042: [emsesp] Me(0x0B) -R-> boiler(0x08), HPSettings3(0x049D), length: 255
2024-08-20 16:52:59.598 TRACE 3043: [emsesp] boiler(0x08) -W-> Me(0x0B), HPSettings3(0x049D), data: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
2024-08-20 16:52:59.598 TRACE 3044: [emsesp] Me(0x0B) -R-> boiler(0x08), HPEnergy(0x04AE), length: 255
2024-08-20 16:52:59.655 TRACE 3045: [emsesp] boiler(0x08) -W-> Me(0x0B), HPEnergy(0x04AE), data: 00 02 3C EB 00 00 2A 6E 00 00 00 04 00 01 B1 B4 00 00 00 62 00 00 60 C7
2024-08-20 16:52:59.675 TRACE 3046: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3B (offset 9)
2024-08-20 16:52:59.990 TRACE 3047: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3C (offset 9)
2024-08-20 16:53:00.220 TRACE 3048: [emsesp] Me(0x0B) -R-> boiler(0x08), HPEnergy(0x04AE), length: 231 (offset 24)
2024-08-20 16:53:00.260 TRACE 3049: [emsesp] boiler(0x08) -W-> Me(0x0B), HPEnergy(0x04AE), data: 00 00 00 00 00 00 00 00 (offset 24)
2024-08-20 16:53:00.260 TRACE 3050: [emsesp] Me(0x0B) -R-> boiler(0x08), HPMeters(0x04AF), length: 255
2024-08-20 16:53:00.295 TRACE 3051: [emsesp] boiler(0x08) -W-> Me(0x0B), HPMeters(0x04AF), data: 00 00 C8 0F 00 00 C0 8F 00 00 07 80 00 00 04 7A 00 00 01 B1 00 00 14 10
2024-08-20 16:53:00.372 TRACE 3052: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3D (offset 9)
2024-08-20 16:53:00.644 TRACE 3053: [emsesp] Me(0x0B) -R-> boiler(0x08), HPMeters(0x04AF), length: 231 (offset 24)
2024-08-20 16:53:00.684 TRACE 3054: [emsesp] boiler(0x08) -W-> Me(0x0B), HPMeters(0x04AF), data: 00 00 18 99 00 00 05 9B 00 00 8F 17 00 00 01 E5 00 00 18 DD 00 00 00 00 (offset 24)
2024-08-20 16:53:00.765 TRACE 3055: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3E (offset 9)
2024-08-20 16:53:00.997 TRACE 3056: [emsesp] thermostat(0x10) -W-> boiler(0x08), ?(0x04C0), data: 00 00
2024-08-20 16:53:01.023 TRACE 3057: [emsesp] thermostat(0x10) -W-> boiler(0x08), ?(0x02EA), data: 00
2024-08-20 16:53:01.048 TRACE 3058: [emsesp] thermostat(0x10) -W-> boiler(0x08), ?(0xE7), data: 01 01 00
2024-08-20 16:53:01.082 TRACE 3059: [emsesp] thermostat(0x10) -W-> boiler(0x08), ?(0x04F2), data: 01 13 64 00 01
2024-08-20 16:53:01.122 TRACE 3060: [emsesp] thermostat(0x10) -B-> All(0x00), ?(0x0507), data: 00 00 00 00 00 00 00 00
2024-08-20 16:53:01.345 TRACE 3061: [emsesp] thermostat(0x10) -B-> All(0x00), RC300Monitor(0x02A5), data: 01 0D 40 29 13 00 29 29 05 A0 02 03 00 00 00 00 00 00 00 11
2024-08-20 16:53:01.555 TRACE 3062: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3F (offset 9)
2024-08-20 16:53:01.745 TRACE 3063: [emsesp] Me(0x0B) -R-> boiler(0x08), HPMeters(0x04AF), length: 207 (offset 48)
2024-08-20 16:53:01.765 TRACE 3064: [emsesp] boiler(0x08) -W-> Me(0x0B), HPMeters(0x04AF), data: 00 00 00 00 00 00 00 00 (offset 48)
2024-08-20 16:53:01.765 TRACE 3065: [emsesp] Me(0x0B) -R-> boiler(0x08), HPPressure(0x02CC), length: 255
2024-08-20 16:53:01.790 TRACE 3066: [emsesp] boiler(0x08) -W-> Me(0x0B), HPPressure(0x02CC), data: 05 (offset 9)
2024-08-20 16:53:01.870 TRACE 3067: [emsesp] thermostat(0x10) -B-> All(0x00), ?(0x0508), data: 00 00 00 00 00 00 00 00
2024-08-20 16:53:02.067 TRACE 3068: [emsesp] thermostat(0x10) -B-> All(0x00), ?(0x0509), data: 00 00 00 00 00 00 00 00
2024-08-20 16:53:02.264 TRACE 3069: [emsesp] thermostat(0x10) -B-> All(0x00), ?(0x050A), data: 00 00 00 00 00 00 00 00
2024-08-20 16:53:02.445 TRACE 3070: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 40 (offset 9)
2024-08-20 16:53:02.634 TRACE 3071: [emsesp] thermostat(0x10) -W-> boiler(0x08), ?(0x061E), data: 01
2024-08-20 16:53:02.676 TRACE 3072: [emsesp] thermostat(0x10) -B-> All(0x00), RCTime(0x06), data: 18 08 10 14 35 0A 01 01 10 FF 00
2024-08-20 16:53:02.882 TRACE 3073: [emsesp] thermostat(0x10) -B-> All(0x00), RC300WWmode2(0x031D), data: 00 00 00 00 00 00 00 00 01 01 58 0A
2024-08-20 16:53:03.064 TRACE 3074: [emsesp] thermostat(0x10) -B-> All(0x00), RC300Monitor(0x02A5), data: 07 (offset 45)
2024-08-20 16:53:03.291 TRACE 3075: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3F (offset 9)
2024-08-20 16:53:03.521 TRACE 3076: [emsesp] thermostat(0x10) -B-> All(0x00), RC300Floordry(0x0267), data: 00 00
2024-08-20 16:53:03.709 TRACE 3077: [emsesp] thermostat(0x10) -B-> All(0x00), ?(0x059D), data: 00 01 00 00
2024-08-20 16:53:03.943 TRACE 3078: [emsesp] thermostat(0x10) -B-> All(0x00), RC300Monitor(0x02A5), data: 03 00 00 00 00 00 00 00 00 00 00 10 64 37 00 00 00 34 00 00 00 00 01 00 00 (offset 20)
2024-08-20 16:53:04.160 TRACE 3079: [emsesp] Me(0x0B) -R-> boiler(0x08), HPPressure(0x02CC), length: 245 (offset 10)
2024-08-20 16:53:04.164 TRACE 3080: [emsesp] boiler(0x08) -W-> Me(0x0B), HPPressure(0x02CC), data: <empty> (offset 10)
2024-08-20 16:53:04.164 TRACE 3081: [emsesp] Me(0x0B) -R-> thermostat(0x10), RC300Monitor(0x02A5), length: 255
2024-08-20 16:53:04.266 TRACE 3082: [emsesp] thermostat(0x10) -W-> Me(0x0B), RC300Monitor(0x02A5), data: 01 0D 40 29 13 00 29 29 05 A0 02 03 00 00 00 00 00 00 00 11 03 00 00 00 00
2024-08-20 16:53:04.775 TRACE 3083: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 40 (offset 9)
2024-08-20 16:53:05.049 TRACE 3084: [emsesp] Me(0x0B) -R-> thermostat(0x10), RC300Monitor(0x02A5), length: 230 (offset 25)
2024-08-20 16:53:05.136 TRACE 3085: [emsesp] thermostat(0x10) -W-> Me(0x0B), RC300Monitor(0x02A5), data: 00 00 00 00 00 00 10 64 37 00 00 00 34 00 00 00 00 01 00 00 07 (offset 25)
2024-08-20 16:53:05.136 TRACE 3086: [emsesp] Me(0x0B) -R-> thermostat(0x10), RC300Set(0x02B9), length: 255
2024-08-20 16:53:05.213 TRACE 3087: [emsesp] thermostat(0x10) -W-> Me(0x0B), RC300Set(0x02B9), data: 00 00 2C 00 28 03 00 00 26 00 2A 01 E1 00 00 00 00 29 00 01 00 01 2A 00 01
2024-08-20 16:53:05.742 TRACE 3088: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorSlowPlus2(0xE3), data: 00 00 10 00 00 00 00 00 00 00 00 00 B4 00 00 00 00 00 00 00
2024-08-20 16:53:05.914 TRACE 3089: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 40 (offset 9)
2024-08-20 16:53:06.086 TRACE 3090: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3F (offset 9)
2024-08-20 16:53:06.331 TRACE 3091: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorFastPlus(0xE4), data: 13 00 B4 00 19 01 00 00 00 00 00 00 D0 00 00 0F 00 00 B4 (offset 6)
2024-08-20 16:53:06.500 TRACE 3092: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorFastPlus(0xE4), data: 04 34 (offset 36)
2024-08-20 16:53:06.673 TRACE 3093: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3E (offset 9)
2024-08-20 16:53:06.888 TRACE 3094: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3D (offset 9)
2024-08-20 16:53:07.084 TRACE 3095: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorWWPlus(0xE9), data: 3C 02 5C 02 56 00 00 00 00 3E 3C 00 00 00 00 00 00 00 00 00 00 00 00 3C
2024-08-20 16:53:07.257 TRACE 3096: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3C (offset 9)
2024-08-20 16:53:07.442 TRACE 3097: [emsesp] Me(0x0B) -R-> thermostat(0x10), RC300Set(0x02B9), length: 230 (offset 25)
2024-08-20 16:53:07.477 TRACE 3098: [emsesp] thermostat(0x10) -W-> Me(0x0B), RC300Set(0x02B9), data: 30 22 00 01 29 00 (offset 25)
2024-08-20 16:53:07.477 TRACE 3099: [emsesp] Me(0x0B) -R-> thermostat(0x10), RC300Summer(0x02AF), length: 255
2024-08-20 16:53:07.549 TRACE 3100: [emsesp] thermostat(0x10) -W-> Me(0x0B), RC300Summer(0x02AF), data: 00 00 00 00 1E 2D 00 00 19 0F 00 00 00 19
2024-08-20 16:53:07.549 TRACE 3101: [emsesp] Me(0x0B) -R-> thermostat(0x10), RC300Curves(0x029B), length: 255
2024-08-20 16:53:07.610 TRACE 3102: [emsesp] thermostat(0x10) -W-> Me(0x0B), RC300Curves(0x029B), data: 01 03 00 00 00 02 05 37 1E
2024-08-20 16:53:08.281 TRACE 3103: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 39 (offset 9)
2024-08-20 16:53:08.507 TRACE 3104: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 38 (offset 9)
2024-08-20 16:53:08.778 TRACE 3105: [emsesp] Me(0x0B) -R-> thermostat(0x10), RC300Summer2(0x0471), length: 255
2024-08-20 16:53:08.817 TRACE 3106: [emsesp] thermostat(0x10) -W-> Me(0x0B), RC300Summer2(0x0471), data: 03 0F 03 03 04 14 01 04
2024-08-20 16:53:08.817 TRACE 3107: [emsesp] Me(0x0B) -R-> thermostat(0x10), RC300Set2(0x02CC), length: 255
2024-08-20 16:53:08.880 TRACE 3108: [emsesp] thermostat(0x10) -W-> Me(0x0B), RC300Set2(0x02CC), data: 00 00 00 00 00 00 00 00 00 05
2024-08-20 16:53:08.880 TRACE 3109: [emsesp] Me(0x0B) -R-> thermostat(0x10), HPSet(0x0467), length: 255
2024-08-20 16:53:08.933 TRACE 3110: [emsesp] thermostat(0x10) -W-> Me(0x0B), HPSet(0x0467), data: 0A 11 00 01 03 FF
2024-08-20 16:53:09.916 TRACE 3111: [emsesp] gateway(0x48) -R-> boiler(0x08), ValueConfig(0xF9), length: 17, data: FF 03 99 0B
2024-08-20 16:53:09.946 TRACE 3112: [emsesp] boiler(0x08) -W-> gateway(0x48), ValueConfig(0xF9), data: FF 03 99 0B 07 00 00 00 28 00 00 00 3C 00 00 00 46 00 00 00 3C
2024-08-20 16:53:10.019 TRACE 3113: [emsesp] Me(0x0B) -R-> thermostat(0x10), HPMode(0x0291), length: 255
2024-08-20 16:53:10.053 TRACE 3114: [emsesp] thermostat(0x10) -W-> Me(0x0B), HPMode(0x0291), data: 01 00 00 06 00 02
2024-08-20 16:53:10.053 TRACE 3115: [emsesp] Me(0x0B) -R-> thermostat(0x10), HPMode(0x0292), length: 255
2024-08-20 16:53:10.107 TRACE 3116: [emsesp] thermostat(0x10) -W-> Me(0x0B), HPMode(0x0292), data: 00 00 00 00 00 00
2024-08-20 16:53:10.107 TRACE 3117: [emsesp] Me(0x0B) -R-> thermostat(0x10), HPMode(0x0293), length: 255
2024-08-20 16:53:10.161 TRACE 3118: [emsesp] thermostat(0x10) -W-> Me(0x0B), HPMode(0x0293), data: 00 00 00 00 00 00
2024-08-20 16:53:10.853 TRACE 3119: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3B (offset 9)
2024-08-20 16:53:11.025 TRACE 3120: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3C (offset 9)
2024-08-20 16:53:11.304 TRACE 3121: [emsesp] Me(0x0B) -R-> thermostat(0x10), HPMode(0x0294), length: 255
2024-08-20 16:53:11.338 TRACE 3122: [emsesp] thermostat(0x10) -W-> Me(0x0B), HPMode(0x0294), data: 00 00 00 00 00 00
2024-08-20 16:53:11.338 TRACE 3123: [emsesp] Me(0x0B) -R-> thermostat(0x10), RC300WWmode(0x02F5), length: 255
2024-08-20 16:53:11.432 TRACE 3124: [emsesp] thermostat(0x10) -W-> Me(0x0B), RC300WWmode(0x02F5), data: 01 FF 04 02 00 FF 30 00 00 08 04 00 00 00 00 00 00 00 00 00 00 00 00 00
2024-08-20 16:53:11.902 TRACE 3125: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3B (offset 9)
2024-08-20 16:53:12.074 TRACE 3126: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3A (offset 9)
2024-08-20 16:53:12.404 TRACE 3127: [emsesp] Me(0x0B) -R-> thermostat(0x10), RC300WWmode(0x02F5), length: 231 (offset 24)
2024-08-20 16:53:12.408 TRACE 3128: [emsesp] thermostat(0x10) -W-> Me(0x0B), RC300WWmode(0x02F5), data: <empty> (offset 24)
2024-08-20 16:53:12.408 TRACE 3129: [emsesp] Me(0x0B) -R-> thermostat(0x10), RC300OutdoorTemp(0x023A), length: 255
2024-08-20 16:53:12.447 TRACE 3130: [emsesp] thermostat(0x10) -W-> Me(0x0B), RC300OutdoorTemp(0x023A), data: 01 0D
2024-08-20 16:53:12.447 TRACE 3131: [emsesp] Me(0x0B) -R-> thermostat(0x10), RC300Settings(0x0240), length: 255
2024-08-20 16:53:12.561 TRACE 3132: [emsesp] thermostat(0x10) -W-> Me(0x0B), RC300Settings(0x0240), data: 00 03 00 00 00 00 00 00 02 F4 06 FF 00 00 02 00 32 00 00 00 00 00 01 FF (offset 1)
2024-08-20 16:53:13.072 TRACE 3133: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 39 (offset 9)
2024-08-20 16:53:13.295 TRACE 3134: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3A (offset 9)
2024-08-20 16:53:13.494 TRACE 3135: [emsesp] Me(0x0B) -R-> thermostat(0x10), RC300Settings(0x0240), length: 230 (offset 25)
2024-08-20 16:53:13.527 TRACE 3136: [emsesp] thermostat(0x10) -W-> Me(0x0B), RC300Settings(0x0240), data: <empty> (offset 25)
2024-08-20 16:53:13.527 TRACE 3137: [emsesp] Me(0x0B) -R-> thermostat(0x10), HybridSettings(0xBB), length: 255
2024-08-20 16:53:13.560 TRACE 3138: [emsesp] thermostat(0x10) -W-> Me(0x0B), HybridSettings(0xBB), data: 00 (offset 14)
2024-08-20 16:53:13.584 TRACE 3139: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3B (offset 9)
2024-08-20 16:53:13.867 TRACE 3140: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3C (offset 9)
2024-08-20 16:53:14.093 TRACE 3141: [emsesp] Me(0x0B) -R-> thermostat(0x10), HybridSettings(0xBB), length: 240 (offset 15)
2024-08-20 16:53:14.096 TRACE 3142: [emsesp] thermostat(0x10) -W-> Me(0x0B), HybridSettings(0xBB), data: <empty> (offset 15)
2024-08-20 16:53:14.096 TRACE 3143: [emsesp] Me(0x0B) -R-> thermostat(0x10), PVSettings(0x023E), length: 255
2024-08-20 16:53:14.167 TRACE 3144: [emsesp] thermostat(0x10) -W-> Me(0x0B), PVSettings(0x023E), data: 02 02 00 00 00 00 00
2024-08-20 16:53:14.167 TRACE 3145: [emsesp] Me(0x0B) -R-> thermostat(0x10), ?(0x016E), length: 1
2024-08-20 16:53:14.205 TRACE 3146: [emsesp] thermostat(0x10) -W-> Me(0x0B), ?(0x016E), data: 00
2024-08-20 16:53:14.205 TRACE 3147: [emsesp] Me(0x0B) -R-> boiler(0x08), ?(0x04AA), length: 2
2024-08-20 16:53:14.232 TRACE 3148: [emsesp] boiler(0x08) -W-> Me(0x0B), ?(0x04AA), data: 02 4F
2024-08-20 16:53:14.232 TRACE 3149: [emsesp] Me(0x0B) -R-> thermostat(0x10), RC300WWmode2(0x031D), length: 1 (offset 8)
2024-08-20 16:53:14.283 TRACE 3150: [emsesp] thermostat(0x10) -W-> Me(0x0B), RC300WWmode2(0x031D), data: 01 (offset 8)
2024-08-20 16:53:14.283 TRACE 3151: [emsesp] Me(0x0B) -R-> gateway(0x48), ?(0x04A7), length: 2
2024-08-20 16:53:14.331 TRACE 3152: [emsesp] gateway(0x48) -W-> Me(0x0B), ?(0x04A7), data: 00 00
2024-08-20 16:53:14.350 TRACE 3153: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3D (offset 9)
2024-08-20 16:53:14.520 TRACE 3154: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorFastPlus(0xE4), data: 04 2F (offset 36)
2024-08-20 16:53:14.788 TRACE 3155: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3E (offset 9)
2024-08-20 16:53:15.073 TRACE 3156: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3D (offset 9)
2024-08-20 16:53:15.264 TRACE 3157: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorSlowPlus2(0xE3), data: 00 00 10 00 00 00 00 00 00 00 00 00 B4 00 00 00 00 00 00 00
2024-08-20 16:53:15.454 TRACE 3158: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorFastPlus(0xE4), data: 13 00 B4 00 19 01 00 00 00 00 00 00 D0 00 00 0F 00 00 B4 (offset 6)
2024-08-20 16:53:15.667 TRACE 3159: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorFastPlus(0xE4), data: 04 2D (offset 36)
2024-08-20 16:53:15.840 TRACE 3160: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3E (offset 9)
2024-08-20 16:53:16.036 TRACE 3161: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorWWPlus(0xE9), data: 3C 02 5C 02 56 00 00 00 00 3E 3C 00 00 00 00 00 00 00 00 00 00 00 00 3C
2024-08-20 16:53:16.261 TRACE 3162: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3F (offset 9)
2024-08-20 16:53:17.099 TRACE 3163: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 40 (offset 9)
2024-08-20 16:53:17.271 TRACE 3164: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3F (offset 9)
2024-08-20 16:53:17.599 TRACE 3165: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3E (offset 9)
2024-08-20 16:53:17.804 TRACE 3166: [emsesp] gateway(0x48) -R-> boiler(0x08), ValueConfig(0xF9), length: 17, data: FF 03 99 05
2024-08-20 16:53:17.807 TRACE 3167: [emsesp] boiler(0x08) -W-> gateway(0x48), ValueConfig(0xF9), data: FF 03 99 05 00
2024-08-20 16:53:17.865 TRACE 3168: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3D (offset 9)
2024-08-20 16:53:18.202 TRACE 3169: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3C (offset 9)
2024-08-20 16:53:18.694 TRACE 3170: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3B (offset 9)
2024-08-20 16:53:19.261 TRACE 3171: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3A (offset 9)
2024-08-20 16:53:19.595 TRACE 3172: [emsesp] gateway(0x48) -R-> boiler(0x08), ValueConfig(0xF9), length: 17, data: FF 03 99 06
2024-08-20 16:53:19.598 TRACE 3173: [emsesp] boiler(0x08) -W-> gateway(0x48), ValueConfig(0xF9), data: FF 03 99 06 00
2024-08-20 16:53:20.076 TRACE 3174: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3B (offset 9)
2024-08-20 16:53:20.404 TRACE 3175: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3C (offset 9)
2024-08-20 16:53:20.683 TRACE 3176: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3D (offset 9)
2024-08-20 16:53:21.162 TRACE 3177: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3E (offset 9)
2024-08-20 16:53:21.693 TRACE 3178: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3F (offset 9)
2024-08-20 16:53:22.392 TRACE 3179: [emsesp] gateway(0x48) -R-> thermostat(0x10), ValueConfig(0xF9), length: 17, data: FF 00 66 0A
2024-08-20 16:53:22.454 TRACE 3180: [emsesp] thermostat(0x10) -W-> gateway(0x48), ValueConfig(0xF9), data: FF 00 66 0A 4F 00 00 00 01 00 00 00 02 00 1E 00 05 00 1E 00 02
2024-08-20 16:53:22.474 TRACE 3181: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3E (offset 9)
2024-08-20 16:53:22.690 TRACE 3182: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3D (offset 9)
2024-08-20 16:53:23.081 TRACE 3183: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3C (offset 9)
2024-08-20 16:53:23.459 TRACE 3184: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3B (offset 9)
2024-08-20 16:53:24.086 TRACE 3185: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3A (offset 9)
2024-08-20 16:53:24.565 TRACE 3186: [emsesp] gateway(0x48) -R-> thermostat(0x10), ValueConfig(0xF9), length: 17, data: FF 00 67 0A
2024-08-20 16:53:24.626 TRACE 3187: [emsesp] thermostat(0x10) -W-> gateway(0x48), ValueConfig(0xF9), data: FF 00 67 0A 4F 00 00 00 01 00 00 00 02 00 1E 00 05 00 1E 00 02
2024-08-20 16:53:24.998 TRACE 3188: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 39 (offset 9)
2024-08-20 16:53:25.189 TRACE 3189: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorSlowPlus2(0xE3), data: 00 00 10 00 00 00 00 00 00 00 00 00 B5 00 00 00 00 00 00 00
2024-08-20 16:53:25.379 TRACE 3190: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorFastPlus(0xE4), data: 13 00 B5 00 19 01 00 00 00 00 00 00 D0 00 00 0F 00 00 B4 (offset 6)
2024-08-20 16:53:25.594 TRACE 3191: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorFastPlus(0xE4), data: 04 34 (offset 36)
2024-08-20 16:53:25.789 TRACE 3192: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorWWPlus(0xE9), data: 3C 02 5C 02 56 00 00 00 00 3E 3C 00 00 00 00 00 00 00 00 00 00 00 00 3C
2024-08-20 16:53:26.364 TRACE 3193: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 38 (offset 9)
2024-08-20 16:53:26.507 TRACE 3194: [emsesp] gateway(0x48) -R-> thermostat(0x10), ValueConfig(0xF9), length: 17, data: FF 00 68 0A
2024-08-20 16:53:26.507 TRACE 3195: [emsesp] thermostat(0x10) -W-> gateway(0x48), ValueConfig(0xF9), data: FF 00 68 0A 4F 00 00 00 01 00 00 00 02 00 1E 00 05 00 1E 00 02
2024-08-20 16:53:27.220 TRACE 3196: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 37 (offset 9)
2024-08-20 16:53:27.750 TRACE 3197: [emsesp] gateway(0x48) -W-> boiler(0x08), ?(0x04A7), data: 02 74 (offset 4)
2024-08-20 16:53:27.874 TRACE 3198: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 38 (offset 9)
2024-08-20 16:53:28.098 TRACE 3199: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 39 (offset 9)
2024-08-20 16:53:28.371 TRACE 3200: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3A (offset 9)
2024-08-20 16:53:28.597 TRACE 3201: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3B (offset 9)
2024-08-20 16:53:28.815 TRACE 3202: [emsesp] gateway(0x48) -R-> thermostat(0x10), ValueConfig(0xF9), length: 17, data: FF 00 69 0A
2024-08-20 16:53:28.877 TRACE 3203: [emsesp] thermostat(0x10) -W-> gateway(0x48), ValueConfig(0xF9), data: FF 00 69 0A 4F 00 00 00 01 00 00 00 02 00 1E 00 05 00 1E 00 02
2024-08-20 16:53:28.936 TRACE 3204: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3C (offset 9)
2024-08-20 16:53:29.274 TRACE 3205: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3D (offset 9)
2024-08-20 16:53:29.763 TRACE 3206: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3E (offset 9)
2024-08-20 16:53:29.936 TRACE 3207: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3F (offset 9)
2024-08-20 16:53:30.109 TRACE 3208: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 40 (offset 9)
2024-08-20 16:53:30.315 TRACE 3209: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 41 (offset 9)
2024-08-20 16:53:30.487 TRACE 3210: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 42 (offset 9)
2024-08-20 16:53:30.659 TRACE 3211: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 43 (offset 9)
2024-08-20 16:53:30.888 TRACE 3212: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 44 (offset 9)
2024-08-20 16:53:31.200 TRACE 3213: [emsesp] gateway(0x48) -R-> thermostat(0x10), ValueConfig(0xF9), length: 17, data: FF 00 6A 0A
2024-08-20 16:53:31.262 TRACE 3214: [emsesp] thermostat(0x10) -W-> gateway(0x48), ValueConfig(0xF9), data: FF 00 6A 0A 4F 00 00 00 01 00 00 00 02 00 1E 00 05 00 1E 00 02
2024-08-20 16:53:31.266 TRACE 3215: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 45 (offset 9)
2024-08-20 16:53:31.973 TRACE 3216: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 44 (offset 9)
2024-08-20 16:53:32.495 TRACE 3217: [emsesp] gateway(0x48) -R-> thermostat(0x10), ValueConfig(0xF9), length: 17, data: FF 00 6B 0A
2024-08-20 16:53:32.557 TRACE 3218: [emsesp] thermostat(0x10) -W-> gateway(0x48), ValueConfig(0xF9), data: FF 00 6B 0A 4F 00 00 00 01 00 00 00 02 00 1E 00 05 00 1E 00 02
2024-08-20 16:53:32.781 TRACE 3219: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 43 (offset 9)
2024-08-20 16:53:33.370 TRACE 3220: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 42 (offset 9)
2024-08-20 16:53:33.586 TRACE 3221: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 41 (offset 9)
2024-08-20 16:53:34.493 TRACE 3222: [emsesp] gateway(0x48) -R-> thermostat(0x10), ValueConfig(0xF9), length: 17, data: FF 00 6C 0A
2024-08-20 16:53:34.556 TRACE 3223: [emsesp] thermostat(0x10) -W-> gateway(0x48), ValueConfig(0xF9), data: FF 00 6C 0A 4F 00 00 00 01 00 00 00 02 00 1E 00 05 00 1E 00 02
2024-08-20 16:53:35.109 TRACE 3224: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorSlowPlus2(0xE3), data: 00 00 10 00 00 00 00 00 00 00 00 00 B5 00 00 00 00 00 00 00
2024-08-20 16:53:35.299 TRACE 3225: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorFastPlus(0xE4), data: 13 00 B5 00 19 01 00 00 00 00 00 00 D0 00 00 0F 00 00 B4 (offset 6)
2024-08-20 16:53:35.468 TRACE 3226: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorFastPlus(0xE4), data: 04 32 (offset 36)
2024-08-20 16:53:35.708 TRACE 3227: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorWWPlus(0xE9), data: 3C 02 5C 02 56 00 00 00 00 3E 3C 00 00 00 00 00 00 00 00 00 00 00 00 3C
2024-08-20 16:53:35.880 TRACE 3228: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 40 (offset 9)
2024-08-20 16:53:36.110 TRACE 3229: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3F (offset 9)
2024-08-20 16:53:36.283 TRACE 3230: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3E (offset 9)
2024-08-20 16:53:36.549 TRACE 3231: [emsesp] gateway(0x48) -R-> thermostat(0x10), ValueConfig(0xF9), length: 17, data: FF 00 65 0A
2024-08-20 16:53:36.611 TRACE 3232: [emsesp] thermostat(0x10) -W-> gateway(0x48), ValueConfig(0xF9), data: FF 00 65 0A 4F 00 00 00 01 00 00 00 02 00 1E 00 05 00 1E 00 02
2024-08-20 16:53:36.669 TRACE 3233: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3D (offset 9)
2024-08-20 16:53:36.840 TRACE 3234: [emsesp] boiler(0x08) -B-> All(0x00), UBAMonitorFastPlus(0xE4), data: 04 3A (offset 36)
2024-08-20 16:53:37.013 TRACE 3235: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3C (offset 9)
2024-08-20 16:53:37.499 TRACE 3236: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3B (offset 9)
2024-08-20 16:53:38.081 TRACE 3237: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3A (offset 9)
2024-08-20 16:53:38.523 TRACE 3238: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3B (offset 9)
2024-08-20 16:53:38.787 TRACE 3239: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3C (offset 9)
2024-08-20 16:53:39.066 TRACE 3240: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3D (offset 9)
2024-08-20 16:53:39.586 TRACE 3241: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3E (offset 9)
2024-08-20 16:53:40.180 TRACE 3242: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 3F (offset 9)
2024-08-20 16:53:40.566 TRACE 3243: [emsesp] thermostat(0x38) -W-> thermostat(0x10), RemoteHumidity(0x047B), data: 10 34 00 A0
2024-08-20 16:53:40.807 TRACE 3244: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 40 (offset 9)
2024-08-20 16:53:40.979 TRACE 3245: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 41 (offset 9)
2024-08-20 16:53:41.195 TRACE 3246: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 42 (offset 9)
2024-08-20 16:53:41.362 TRACE 3247: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 43 (offset 9)
2024-08-20 16:53:41.506 TRACE 3248: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 44 (offset 9)
2024-08-20 16:53:41.862 TRACE 3249: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 45 (offset 9)
2024-08-20 16:53:42.607 TRACE 3250: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 44 (offset 9)
2024-08-20 16:53:43.304 TRACE 3251: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 43 (offset 9)
2024-08-20 16:53:43.477 TRACE 3252: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 42 (offset 9)
2024-08-20 16:53:44.976 TRACE 3253: [emsesp] boiler(0x08) -B-> All(0x00), ?(0x02D6), data: 04 41 (offset 9)
2024-08-20 16:53:45.148 TRACE 3254: [emsesp] boiler(0x08) -R-> thermostat(0x10), PVSettings(0x023E), length: 1
2024-08-20 16:53:45.171 TRACE 3255: [emsesp] thermostat(0x10) -W-> boiler(0x08), PVSettings(0x023E), data: 02
2024-08-20 16:53:45.181 TRACE 3256: [emsesp] boiler(0x08) -R-> thermostat(0x10), PVSettings(0x023E), length: 1 (offset 3)
2024-08-20 16:53:45.205 TRACE 3257: [emsesp] thermostat(0x10) -W-> boiler(0x08), PVSettings(0x023E), data: 00 (offset 3)
2024-08-20 16:53:45.207 TRACE 3258: [emsesp] boiler(0x08) -R-> thermostat(0x10), PVSettings(0x023E), length: 1 (offset 5)
2024-08-20 16:53:45.222 TRACE 3259: [emsesp] thermostat(0x10) -W-> boiler(0x08), PVSettings(0x023E), data: 00 (offset 5)
2024-08-20 16:53:45.241 TRACE 3260: [emsesp] boiler(0x08) -R-> thermostat(0x10), RC300Settings(0x0240), length: 1 (offset 10)
2024-08-20 16:53:45.272 TRACE 3261: [emsesp] thermostat(0x10) -W-> boiler(0x08), RC300Settings(0x0240), data: F4 (offset 10)
2024-08-20 16:53:45.276 TRACE 3262: [emsesp] boiler(0x08) -R-> thermostat(0x10), RC300Settings(0x0240), length: 1 (offset 12)
2024-08-20 16:53:45.290 TRACE 3263: [emsesp] thermostat(0x10) -W-> boiler(0x08), RC300Settings(0x0240), data: FF (offset 12)
2024-08-20 16:53:45.311 TRACE 3264: [emsesp] boiler(0x08) -R-> thermostat(0x10), RC300Settings(0x0240), length: 1 (offset 24)
2024-08-20 16:53:45.325 TRACE 3265: [emsesp] thermostat(0x10) -W-> boiler(0x08), RC300Settings(0x0240), data: FF (offset 24)
2024-08-20 16:53:45.346 TRACE 3266: [emsesp] boiler(0x08) -R-> thermostat(0x10), HPMode(0x0291), length: 1
2024-08-20 16:53:45.372 TRACE 3267: [emsesp] thermostat(0x10) -W-> boiler(0x08), HPMode(0x0291), data: 01
2024-08-20 16:53:45.382 TRACE 3268: [emsesp] boiler(0x08) -R-> thermostat(0x10), HPMode(0x0291), length: 1 (offset 5)
2024-08-20 16:53:45.404 TRACE 3269: [emsesp] thermostat(0x10) -W-> boiler(0x08), HPMode(0x0291), data: 02 (offset 5)
2024-08-20 16:53:45.407 TRACE 3270: [emsesp] boiler(0x08) -R-> thermostat(0x10), HPMode(0x0292), length: 1
2024-08-20 16:53:45.438 TRACE 3271: [emsesp] thermostat(0x10) -W-> boiler(0x08), HPMode(0x0292), data: 00
2024-08-20 16:53:45.448 TRACE 3272: [emsesp] boiler(0x08) -R-> thermostat(0x10), HPMode(0x0292), length: 1 (offset 5)
2024-08-20 16:53:45.472 TRACE 3273: [emsesp] thermostat(0x10) -W-> boiler(0x08), HPMode(0x0292), data: 00 (offset 5)
2024-08-20 16:53:45.476 TRACE 3274: [emsesp] boiler(0x08) -R-> thermostat(0x10), HPMode(0x0293), length: 1
2024-08-20 16:53:45.511 TRACE 3275: [emsesp] thermostat(0x10) -W-> boiler(0x08), HPMode(0x0293), data: 00
2024-08-20 16:53:45.522 TRACE 3276: [emsesp] boiler(0x08) -R-> thermostat(0x10), HPMode(0x0293), length: 1 (offset 5)
2024-08-20 16:53:45.545 TRACE 3277: [emsesp] thermostat(0x10) -W-> boiler(0x08), HPMode(0x0293), data: 00 (offset 5)
2024-08-20 16:53:45.547 TRACE 3278: [emsesp] boiler(0x08) -R-> thermostat(0x10), HPMode(0x0294), length: 1
2024-08-20 16:53:45.578 TRACE 3279: [emsesp] thermostat(0x10) -W-> boiler(0x08), HPMode(0x0294), data: 00
2024-08-20 16:53:45.588 TRACE 3280: [emsesp] boiler(0x08) -R-> thermostat(0x10), HPMode(0x0294), length: 1 (offset 5)
2024-08-20 16:53:45.611 TRACE 3281: [emsesp] thermostat(0x10) -W-> boiler(0x08), HPMode(0x0294), data: 00 (offset 5)
2024-08-20 16:53:45.614 TRACE 3282: [emsesp] boiler(0x08) -R-> thermostat(0x10), RC300Curves(0x029B), length: 1 (offset 1)
2024-08-20 16:53:45.641 TRACE 3283: [emsesp] thermostat(0x10) -W-> boiler(0x08), RC300Curves(0x029B)
|
On my Buderus WLW186 heatpump with ems-esp 3.7.0-dev.30 I use successful the dhw mode to select between the different dhw modes (eco, eco+, comfort, off and auto). But, when I select the auto mode (time program in the hp) I do not see any feedback which mode is actually active during that auto mode...?! Is there a custom entity where the actual mode during auto is indicated...?
I also use the Buderus Energiemanager and it is increasing the setpoint temperature based on PV power available. Also this works fine and I see the increased temp setpoint, but is there any chance to catch that this happened from the Energiemanager and what the forced settings (power, temp , etc.) from the Energiemanager are...?
The text was updated successfully, but these errors were encountered: