#ifndef SUNEZY_INVERTER_STATUS
#define SUNEZY_INVERTER_STATUS
#include "stdint.h"
#define MAX_LAYOUT_SIZE 50 //theoretical maximum is MAX_PLOAD_SIZE, using 50 to save memory
/*
code, divisor, name
0x00, 10, "Temp-inv" Internal Temperature - deg C
0x0d, 10, "etoday" Accumulated Energy Today - KiloWattHours
0x01, 10, "Vpv1" :ignored
0x02, 10, "Vpv2" :ignored
0x03, 10, "Vpv3" :ignored
0x04, 10, "Ipv1" :ignored
0x05, 10, "Ipv2" :ignored
0x06, 10, "Ipv3" :ignored
0x40, 10, "Vpv" Panel Voltage - Volt
0x41, 10, "Iac" Grid Current - Ampere
0x42, 10, "Vac" Grid Voltage - Volt
0x43, 100, "Fac" Grid Frequency - Hertz
0x44, 1, "Pac" Output Power - Watt
0x45, 1, "Zac" Grid Impedance - milliOhms
0x4748, 10, "E-Total" Accumulated Energy - kiloWattHours
0x494a, 1, "h-Total" Working Hours - Hours
0x4c, 1, "Mode" Operating Mode 0=Wait 1=Normal 2=Fault 3=Permenant Fault
0x7e7f, 1, "Error"
# The 2 error bytes are bit fields, e.g. ERROR[16] = 0x0100
0: ('The GFCI detection circucit is abnormal', 'GFCI ckt fails'),
1: ('The DC output sensor is abnormal', 'DC sensor fails'),
2: ('The 2.5V reference inside is abnormal', 'Ref 2.5V fails'),
3: ('Different measurements between Master and Slave for output DC current', 'DC inj. differs for M-S'),
4: ('Different measurements between Master and Slave for GFCI', 'Ground I differs for M-S'),
5: ('DC Bus voltage is too low', 'Bus-Low-Fail'),
6: ('DC Bus voltage is too High', 'Bus-High-Fail'),
7: ('Device Fault', 'Device-Fault'),
8: ('Delta GridZ is too high', 'Delta Z high'),
9: ('No grid voltage detected', 'No-Utility'),
10: ('Ground current is too high', 'Ground I high'),
11: ('DC bus is not correct', 'DC BUS fails'),
12: ('Master and Slave firmware version is unmatch', 'M-S Version Fail'),
13: ('Internal temperature is high', 'Temperature high'),
14: ('AutoTest failed', 'Test Fail'),
15: ('PV voltage is too high', 'Vpv high'),
16: ('Fan Lock', 'FanLock-Warning'),
17: ('The measured AC voltage is out of tolerable range', 'Vac out of range'),
18: ('Isulation resistance of PV to earth is too low', 'PV insulation low'),
19: ('The DC injection to grid is too high', 'DC injection high'),
20: ('Different measurements between Master and Slave for dl, Fac, Uac or Zac', 'Fac,Zac,Vac differs for M-S'),
21: ('Different measurements between Master and Slave for grid impedance', 'Zac differs for M-S'),
22: ('Different measurements between Master and Slave for grid frequency', 'Fac differs for M-S'),
23: ('Different measurements between Master and Slave for grid voltage', 'Vac differs for M-S'),
24: ('Memory space is full', 'MemFull-Warning'),
25: ('Test of output AC relay fails', 'AC relay fails'),
26: ('The slave impedance is out of tolerable range', 'Zac-Slave out of range'),
27: ('The measured AC impedance is out of range', 'Zac-Master out of range'),
28: ('The slave frequency is out of tolerable range', 'Fac-Slave out of range'),
29: ('The master frequency is out of tolerable range', 'Fac-Master out of range'),
30: ('EEPROM reading or writing error', 'EEPROM fails'),
31: ('Communication between microcontrollers fails', 'Comm fails between M-S'),
*/
class InverterStatus {
public:
InverterStatus();
uint32_t temp,
vpv,
iac,
vac,
fac,
pac,
zac,
etoday,
etotal,
htotal,
mode,
error,
err_gv,
err_gf,
err_gz,
err_temp,
err_pv1,
err_gfc1;
bool parseLayoutElement(uint16_t code, uint16_t value);
uint8_t layout[MAX_LAYOUT_SIZE];
uint8_t layoutLen;
};
void interpretData(InverterStatus& status, uint8_t* data, uint8_t dataLen);
#endif