it should be possible to also integrate the 3 Phase, use 3P under phase and use active_power_w |
I have used 3P: Username = but there is no data unless parameters below are included (which are delivered per phase) And the code assumes a three-phase balanced voltage, where Homewizard API provides individual phase voltages.
Would love to see support for individual phase values on dbus. |
I understand your request, but it does not make a huge difference. As the overall power realtime and longterm energy are still correct, even whatever you put into voltage and current. And that is the main use case. You may submit a PR for the change and we can check to include it. |
I am using Homewizard energy meters which provide a nice restful API and JSON energydata.
https://www.homewizard.com/de-at/
https://api-documentation.homewizard.com/docs/getting-started
The 1Phase meters are already supported:
[TEMPLATE0]
Username =
Password =
DigestAuth = False
Host=0.0.0.0
CUST_SN =
CUST_API_PATH= api/v1/data
CUST_POLLING = 2000
CUST_Total= total_power_export_kwh
CUST_Total_Mult = 1
CUST_Power= active_power_w
CUST_Power_Mult = -1
CUST_Voltage= active_voltage_v
CUST_Current= active_current_a
Phase=
DeviceInstance=
AcPosition=
Name=
Servicename=com.victronenergy.pvinverter
1-PHASE JSON Example
{"wifi_ssid":"xxx","wifi_strength":100,"total_power_import_kwh":23.268,"total_power_import_t1_kwh":23.268,"total_power_export_kwh":716.83,"total_power_export_t1_kwh":716.83,"active_power_w":-138.527,"active_power_l1_w":-138.527,"active_voltage_v":238.369,"active_current_a":0.605,"active_apparent_current_a":0.727,"active_reactive_current_a":0.403,"active_apparent_power_va":166.474,"active_reactive_power_var":92.317,"active_power_factor":0.832,"active_frequency_hz":50}
However it would be nice to see support for a 3PHASE config. With Homeward, data is delivered per phase. Currently there is no support for adding multiple fields to sum these values, or deliver values individually to dbus.
3-PHASE JSON Example:
{"wifi_ssid":"xxx","wifi_strength":70,"total_power_import_kwh":0.24,"total_power_import_t1_kwh":0.24,"total_power_export_kwh":1141.546,"total_power_export_t1_kwh":1141.546,"active_power_w":-237.204,"active_power_l1_w":-78.104,"active_power_l2_w":-79.524,"active_power_l3_w":-79.576,"active_voltage_l1_v":238.441,"active_voltage_l2_v":235.867,"active_voltage_l3_v":237.153,"active_current_a":1.002,"active_current_l1_a":0.329,"active_current_l2_a":0.334,"active_current_l3_a":0.34,"active_apparent_current_a":1.247,"active_apparent_current_l1_a":0.409,"active_apparent_current_l2_a":0.42,"active_apparent_current_l3_a":0.418,"active_reactive_current_a":0.742,"active_reactive_current_l1_a":0.243,"active_reactive_current_l2_a":0.255,"active_reactive_current_l3_a":0.244,"active_apparent_power_va":295.749,"active_apparent_power_l1_va":97.452,"active_apparent_power_l2_va":99.131,"active_apparent_power_l3_va":99.166,"active_reactive_power_var":-177.184,"active_reactive_power_l1_var":-57.925,"active_reactive_power_l2_var":-60.149,"active_reactive_power_l3_var":-59.109,"active_power_factor_l1":0.804,"active_power_factor_l2":0.795,"active_power_factor_l3":0.812,"active_frequency_hz":49.906}
Thanks!