forked from intelligent-environments-lab/CityLearn
-
Notifications
You must be signed in to change notification settings - Fork 0
/
building_attributes.json
executable file
·100 lines (100 loc) · 7.55 KB
/
building_attributes.json
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
{"Building_1":{"File_Name":"Building_1.csv",
"File_Name_Solar_Profile": "solar_generation_1kW.csv",
"Building_Type": 1,
"Climate_Zone": 5,
"Solar_Power_Installed(kW)":120,
"Heat_Pump":{"nominal_power":"autosize", "technical_efficiency":0.20, "t_target_heating":45 ,"t_target_cooling":8},
"Electric_Water_Heater":{"nominal_power":"autosize", "efficiency":0.9},
"Chilled_Water_Tank":{"capacity":2, "loss_coefficient":0.006},
"DHW_Tank":{"capacity":2, "loss_coefficient":0.008},
"Battery":{"capacity":140,"efficiency":0.9,"capacity_loss_coefficient":1e-5,"loss_coefficient":0,"nominal_power":75,"power_efficiency_curve":[[0,0.83],[0.3,0.83],[0.7,0.9],[0.8,0.9],[1,0.85]],"capacity_power_curve":[[0.0 , 1],[0.8, 1],[1.0 ,0.2]]}
},
"Building_2":{"File_Name":"Building_2.csv",
"File_Name_Solar_Profile": "solar_generation_1kW.csv",
"Building_Type": 2,
"Climate_Zone": 5,
"Solar_Power_Installed(kW)":0,
"Heat_Pump":{"nominal_power":"autosize", "technical_efficiency":0.21, "t_target_heating":45 ,"t_target_cooling":9},
"Electric_Water_Heater":{"nominal_power":"autosize", "efficiency":0.92},
"Chilled_Water_Tank":{"capacity":3, "loss_coefficient":0.006},
"DHW_Tank":{"capacity":3, "loss_coefficient":0.008},
"Battery":{"capacity":80,"efficiency":0.9,"capacity_loss_coefficient":1e-5,"loss_coefficient":0,"nominal_power":40,"power_efficiency_curve":[[0,0.8],[0.3,0.85],[0.7,0.92],[0.8,0.91],[1,0.82]],"capacity_power_curve":[[0.0 , 1],[0.8, 0.8],[1.0 ,0.23]]}
},
"Building_3":{"File_Name":"Building_3.csv",
"File_Name_Solar_Profile": "solar_generation_1kW.csv",
"Building_Type": 3,
"Climate_Zone": 5,
"Solar_Power_Installed(kW)":0,
"Heat_Pump":{"nominal_power":"autosize", "technical_efficiency":0.23, "t_target_heating":45 ,"t_target_cooling":8},
"Electric_Water_Heater":{"nominal_power":0.0, "efficiency":0.87},
"Chilled_Water_Tank":{"capacity":2, "loss_coefficient":0.006},
"DHW_Tank":{"capacity":0, "loss_coefficient":0.008},
"Battery":{"capacity":50,"efficiency":0.9,"capacity_loss_coefficient":1e-5,"loss_coefficient":0,"nominal_power":20,"power_efficiency_curve":[[0,0.83],[0.3,0.83],[0.7,0.9],[0.8,0.9],[1,0.85]],"capacity_power_curve":[[0.0, 1],[0.8, 0.9],[1.0 ,0.27]]}
},
"Building_4":{"File_Name":"Building_4.csv",
"File_Name_Solar_Profile": "solar_generation_1kW.csv",
"Building_Type": 4,
"Climate_Zone": 5,
"Solar_Power_Installed(kW)":40,
"Heat_Pump":{"nominal_power":"autosize", "technical_efficiency":0.22, "t_target_heating":45 ,"t_target_cooling":9},
"Electric_Water_Heater":{"nominal_power":0.0, "efficiency":0.9},
"Chilled_Water_Tank":{"capacity":1.5, "loss_coefficient":0.006},
"DHW_Tank":{"capacity":0, "loss_coefficient":0.008},
"Battery":{"capacity":75,"efficiency":0.9,"capacity_loss_coefficient":1e-5,"loss_coefficient":0,"nominal_power":30,"power_efficiency_curve":[[0,0.83],[0.3,0.83],[0.7,0.9],[0.8,0.9],[1,0.85]],"capacity_power_curve":[[0.0 , 1],[0.8, 0.95],[1.0 ,0.2]]}
},
"Building_5":{"File_Name":"Building_5.csv",
"File_Name_Solar_Profile": "solar_generation_1kW.csv",
"Building_Type": 5,
"Climate_Zone": 5,
"Solar_Power_Installed(kW)":25,
"Heat_Pump":{"nominal_power":"autosize", "technical_efficiency":0.24, "t_target_heating":45 ,"t_target_cooling":8},
"Electric_Water_Heater":{"nominal_power":"autosize", "efficiency":0.9},
"Chilled_Water_Tank":{"capacity":3.5, "loss_coefficient":0.006},
"DHW_Tank":{"capacity":1.5, "loss_coefficient":0.008},
"Battery":{"capacity":50,"efficiency":0.9,"capacity_loss_coefficient":1e-5,"loss_coefficient":0,"nominal_power":25,"power_efficiency_curve":[[0,0.8],[0.3,0.83],[0.7,0.87],[0.8,0.85],[1,0.8]],"capacity_power_curve":[[0.0 , 1],[0.8, 0.83],[1.0 ,0.35]]}
},
"Building_6":{"File_Name":"Building_6.csv",
"File_Name_Solar_Profile": "solar_generation_1kW.csv",
"Building_Type": 5,
"Climate_Zone": 5,
"Solar_Power_Installed(kW)":20,
"Heat_Pump":{"nominal_power":"autosize", "technical_efficiency":0.20, "t_target_heating":45 ,"t_target_cooling":9},
"Electric_Water_Heater":{"nominal_power":"autosize", "efficiency":0.85},
"Chilled_Water_Tank":{"capacity":1.5, "loss_coefficient":0.006},
"DHW_Tank":{"capacity":3, "loss_coefficient":0.008},
"Battery":{"capacity":30,"efficiency":0.9,"capacity_loss_coefficient":1e-5,"loss_coefficient":0,"nominal_power":10,"power_efficiency_curve":[[0,0.83],[0.3,0.83],[0.7,0.9],[0.8,0.9],[1,0.85]],"capacity_power_curve":[[0.0 , 1],[0.8, 1],[1.0 ,0.2]]}
},
"Building_7":{"File_Name":"Building_7.csv",
"File_Name_Solar_Profile": "solar_generation_1kW.csv",
"Building_Type": 5,
"Climate_Zone": 5,
"Solar_Power_Installed(kW)":0,
"Heat_Pump":{"nominal_power":"autosize", "technical_efficiency":0.22, "t_target_heating":45 ,"t_target_cooling":8},
"Electric_Water_Heater":{"nominal_power":"autosize", "efficiency":0.9},
"Chilled_Water_Tank":{"capacity":2, "loss_coefficient":0.006},
"DHW_Tank":{"capacity":2, "loss_coefficient":0.008},
"Battery":{"capacity":40,"efficiency":0.9,"capacity_loss_coefficient":1e-5,"loss_coefficient":0,"nominal_power":15,"power_efficiency_curve":[[0,0.83],[0.3,0.83],[0.7,0.9],[0.8,0.9],[1,0.85]],"capacity_power_curve":[[0.0 , 1],[0.8, 0.85],[1.0 ,0.25]]}
},
"Building_8":{"File_Name":"Building_8.csv",
"File_Name_Solar_Profile": "solar_generation_1kW.csv",
"Building_Type": 5,
"Climate_Zone": 5,
"Solar_Power_Installed(kW)":0,
"Heat_Pump":{"nominal_power":"autosize", "technical_efficiency":0.24, "t_target_heating":45 ,"t_target_cooling":9},
"Electric_Water_Heater":{"nominal_power":"autosize", "efficiency":0.93},
"Chilled_Water_Tank":{"capacity":3, "loss_coefficient":0.006},
"DHW_Tank":{"capacity":3, "loss_coefficient":0.008},
"Battery":{"capacity":30,"efficiency":0.9,"capacity_loss_coefficient":1e-5,"loss_coefficient":0,"nominal_power":10,"power_efficiency_curve":[[0,0.8],[0.3,0.85],[0.7,0.9],[0.8,0.9],[1,0.85]],"capacity_power_curve":[[0.0 , 1],[0.8, 1],[1.0 ,0.3]]}
},
"Building_9":{"File_Name":"Building_9.csv",
"File_Name_Solar_Profile": "solar_generation_1kW.csv",
"Building_Type": 5,
"Climate_Zone": 5,
"Solar_Power_Installed(kW)":0,
"Heat_Pump":{"nominal_power":"autosize", "technical_efficiency":0.22, "t_target_heating":45 ,"t_target_cooling":8},
"Electric_Water_Heater":{"nominal_power":"autosize", "efficiency":0.9},
"Chilled_Water_Tank":{"capacity":3, "loss_coefficient":0.006},
"DHW_Tank":{"capacity":3, "loss_coefficient":0.008},
"Battery":{"capacity":35,"efficiency":0.9,"capacity_loss_coefficient":1e-5,"loss_coefficient":0,"nominal_power":20,"power_efficiency_curve":[[0,0.83],[0.3,0.83],[0.7,0.9],[0.8,0.9],[1,0.85]],"capacity_power_curve":[[0.0 , 1],[0.8, 1],[1.0 ,0.3]]}
}
}