Notifications
You must be signed in to change notification settings - Fork 304
/
Copy path08..hc.tsp
132 lines (101 loc) · 3.09 KB
/
08..hc.tsp
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
import "@ebusd/ebus-typespec";
import "./_templates.tsp";
import "../opdata_inc.tsp";
using Ebus;
using Ebus.Num;
using Ebus.Dtm;
using Ebus.Str;
namespace Wolf;
@zz(0x08) // needed here for write to source address calculation
namespace hc {
/** Betriebsdaten des Reglers an den Feuerungsautomaten */
@write(true)
model Operation is Opdata_inc.HcOperation;
/** Sollwertübertragung des Reglers an andere Regler */
@write(true)
model RcTarget is Opdata_inc.RcTarget;
/** HG 01 - Hysterese Vorlauftemperatur (5-30) */
@ext(0x22, 0)
model Hg01 is Register<temp10>;
/** HG 02 - Untere Geblaesedrehzahl (25-100) */
@ext(0x5a, 1)
model Hg02 is ReadonlyRegister<percent>;
/** HG 03 - Obere Geblaesedrehzahl Warmwasser */
@ext(0x59, 1)
model Hg03 is ReadonlyRegister<percent>;
/** HG 04 - Obere Geblaesedrehzahl Heizung (1-100) */
@id(0x3f, 1)
model Hg04 is ReadonlyRegister<percent>;
/** HG 06 - Heizkreispumpenbetriebsart (0-2) */
@id(0x41, 1)
model Hg06 is Register<UIN>;
/** HG 07 - Heizkreispumpennachlauf (0-30) */
@id(0x42, 1)
model Hg07 is Register<minutes>;
/** HG 08 - Maximale Vorlaufsolltemperatur (40-90) */
@id(0x84, 0x2)
model Hg08 is Register<temp10>;
/** HG 09 - Taktsperre (1-30) */
@id(0x43, 1)
model Hg09 is Register<minutes>;
/** HG 10 - eBus-Adresse */
@id(0x78, 1)
model Hg10 is ReadonlyRegister<UIN>;
/** HG 11 - Warmwasserschnellstart */
@id(0x6a, 1)
model Hg11 is ReadonlyRegister<temp10>;
/** HG 12 - Gasart */
@id(0x6b, 1)
model Hg12 is ReadonlyRegister<UIN>;
/** HG 15 - Speicherhysterese (1-30) */
@id(0x40, 1)
model Hg15 is Register<temp10>;
/** HG 16 - Pumpenleistung HK minimal (20-100) */
@id(0x55, 1)
model Hg16 is Register<minutes>;
/** HG 17 - Pumpenleistung HK maximal (20-100) */
@id(0x56, 1)
model Hg17 is Register<minutes>;
/** HG 21 - Kesselminimaltemperatur */
@id(0x1f, 0)
model Hg21 is Register<temp10>;
/** HG 22 - Kesselmaximaltemperatur */
@id(0x27, 0)
model Hg22 is Register<temp10>;
/** HG 73 - Io-Istwert */
@id(0x70, 1)
model Hg73 is ReadonlyRegister<minutes>;
/** HG 74 - Geblaesedrehzahl */
@id(0xf6, 1)
model Hg74 is ReadonlyRegister<speed>;
/** HG 75 - Warmwasserdurchsatz */
@id(0x6c, 1)
model Hg75 is ReadonlyRegister<minutes>;
/** HG 9x - Netzbetriebsstunden */
@id(0x28, 0x2)
model Hg9x is ReadonlyRegister<hours>;
/** HG 90 - Brennerbetriebsstunden */
@id(0x2a, 0x2)
model Hg90 is ReadonlyRegister<hours>;
/** HG 91 - Brennerstarts */
@id(0x26, 0x2)
model Hg91 is ReadonlyRegister<UIN>;
/** Vorlauf Sollwert */
@id(0x2, 0)
model Flowtempdesired is ReadonlyRegister<temp10>;
/** Vorlauf Istwert */
@id(0xd, 0)
model Flowtemp is ReadonlyRegister<temp10>;
/** Ruecklauf Ist-Temperatur */
@id(0x16, 0)
model Returntemp is ReadonlyRegister<temp10>;
/** Warmwasser Solltemperatur */
@id(0x3, 0)
model Hwctempdesired is ReadonlyRegister<temp10>;
/** Warmwasser Ist-Temperatur */
@id(0xe, 0)
model Hwctemp is ReadonlyRegister<temp10>;
/** PWM Pumpe */
@id(0x6d, 1)
model Pump is ReadonlyRegister<percent>;
}