@eltonjrv
Copy link

eltonjrv commented Apr 6, 2020

Describe the bug
Trying to run Rawtools for quality control analysis along with a database search on TMT10 raw data which has an empty channel.

Description of raw file
MS2 - TMT10.

Command line arguments
$ mono /usr/local/RawTools/RawTools.exe -d . -qc gluc-qc_Btau_trembl -db ../Btaurus-uniprot-trembl.fasta -fmods 57.0214@C -vmods 15.9949@M -N 1000 -X /usr/local/RawTools/tandem-linux-15-12-15-2/bin/

Command line output
Processing: /run/media/elton/TOSHIBA EXT/TMTrawData/glucose/./130619_Fraction_1.raw

Determing MS analysis order... Done!
Extracting scan indices: 100%
Checking for orphaned scans: 100%

================ Scan indexing report ================

Total scans in file: 62959

Scans linked: 62959

Orphan scans:

None!

All scans accounted for!

======================================================

Extracting reaction events: 100%
Extracting scan data: 100%
Extracting trailer extras: 100%
Extracting precursor masses: 100%
Extracting retention times: 100%
Analyzing precursor peaks: 100%

Calculating meta data

MS1 isolation interference

MS2 scan cycle density

Ion injection time

Duty cycle

Intensity distribution

Summed intensities

Calculating metrics

Unhandled Exception:
System.MissingMethodException: Method 'Array.Empty' not found.
at RawTools.QC.Search.WriteSearchMGF (RawTools.WorkFlows.WorkflowParameters parameters, RawTools.Data.Collections.CentroidStreamCollection centroids, RawTools.Data.Collections.SegmentScanCollection segments, RawTools.Data.Collections.RetentionTimeCollection retentionTimes, RawTools.Data.Collections.PrecursorMassCollection precursorMasses, RawTools.Data.Collections.PrecursorScanCollection precursorScans, RawTools.Data.Collections.TrailerExtraCollection trailerExtras, RawTools.Data.Containers.MethodDataContainer methodData, RawTools.Data.Containers.ScanIndex index, System.String rawFileName, Boolean fixedScans) <0x4062dcb0 + 0x000d7> in :0
at RawTools.WorkFlows.WorkFlowsDDA.UniversalDDA (IRawFileThreadManager rawFileThreadManager, RawTools.WorkFlows.WorkflowParameters parameters, RawTools.QC.QcDataCollection qcDataCollection) <0x405a7000 + 0x0099b> in :0
at RawTools.Program.Run (System.Collections.Generic.Dictionary2 opts) <0x40569650 + 0x00cb7> in <filename unknown>:0 at RawTools.Program.Main (System.String[] args) <0x404e3e30 + 0x0021f> in <filename unknown>:0 [ERROR] FATAL UNHANDLED EXCEPTION: System.MissingMethodException: Method 'Array.Empty' not found. at RawTools.QC.Search.WriteSearchMGF (RawTools.WorkFlows.WorkflowParameters parameters, RawTools.Data.Collections.CentroidStreamCollection centroids, RawTools.Data.Collections.SegmentScanCollection segments, RawTools.Data.Collections.RetentionTimeCollection retentionTimes, RawTools.Data.Collections.PrecursorMassCollection precursorMasses, RawTools.Data.Collections.PrecursorScanCollection precursorScans, RawTools.Data.Collections.TrailerExtraCollection trailerExtras, RawTools.Data.Containers.MethodDataContainer methodData, RawTools.Data.Containers.ScanIndex index, System.String rawFileName, Boolean fixedScans) <0x4062dcb0 + 0x000d7> in <filename unknown>:0 at RawTools.WorkFlows.WorkFlowsDDA.UniversalDDA (IRawFileThreadManager rawFileThreadManager, RawTools.WorkFlows.WorkflowParameters parameters, RawTools.QC.QcDataCollection qcDataCollection) <0x405a7000 + 0x0099b> in <filename unknown>:0 at RawTools.Program.Run (System.Collections.Generic.Dictionary2 opts) <0x40569650 + 0x00cb7> in :0
at RawTools.Program.Main (System.String[] args) <0x404e3e30 + 0x0021f> in :0

[Paste output here, between the triple quotes]

Screenshots
If applicable, add screenshots to help explain your problem.

Desktop & RawTools information:

  • OS: [e.g. iOS]
  • RawTools version: [e.g. 1.3.3]

Additional context
Add any other context about the problem here.

@kevinkovalchik
Copy link
Owner

kevinkovalchik commented Apr 6, 2020 via email

@chrishuges
Copy link
Collaborator

I can take a look at this as well. Can you try updating to the latest version of the software and trying this command again?

Thanks,
Chris

@eltonjrv
Copy link
Author

I'm already using the latest 2.0.2 one.
Is there any other suggestion?
Thank, though.

@chrishuges
Copy link
Collaborator

Yes, my mistake. I misread the version.

If you process this raw file without a search, just in the regular raw tools pipeline, including mgf creation and quant, does it work without error?

@eltonjrv
Copy link
Author

Yes, the regular "RawTools for quantification" command work well on the same data.

@chrishuges
Copy link
Collaborator

I can't seem to reproduce this error on my own system (CentOS7, RawTools 2.0.2) using a command essentially the same as yours (relative paths, same input flags) and a DDA TMT file (MS2 TMT, or MS3 TMT).

Is it at all possible to share the raw file giving you an issue so I can test it on my system to help track down where the issue might be?

@eltonjrv
Copy link
Author

Thanks for your prompt attention on that, Chirs!
I don't think the PI owner of that data would allow such thing. Sorry!
Did you get on my initial message that it is a TMT 10-plex lacking one channel (we only have 9 samples). Could that be the reason of this issue?

@chrishuges
Copy link
Collaborator

Yes, the TMT empty channel should make no difference. The test runs I did on my system also had empty channels, just to make sure.

Is there anything else you can tell me about the method used to acquire the data? Instrument, acquisition method, sample complexity? Any details you can give would be helpful.

Having the raw data would help a lot. Just to say, in case this helps, but I have no way of telling anything about the data from just the raw file. Without knowing the TMT sample assignments, what the sample is, or where it is from, it is impossible for me to do anything of use with these data beyond testing it with our tool.

@kevinkovalchik
Copy link
Owner

kevinkovalchik commented Apr 18, 2020 via email

@kevinkovalchik
Copy link
Owner

This could possibly be an issue with an old version of Mono. Is it possible to update and try with the new version?

@eltonjrv
Copy link
Author

Hey guys,
Thanks again for your attention and sorry for being out for a while!
I've been working on my Windows partition in the past two days due to some particular collaborations' requirements. Once I reboot my laptop on my Fedora partition, I'll tell you which mono version I'm using.
Kevin might be right regarding an outdated mono version, since I also have an outdated Fedora one.
JFYI: I already circumvented this situation two weeks ago by running Comet on all mgf files, and then writing a PERL script to match scans from Comet results to the ones from your RawTools -q output.
But I'm sure it will definitely be cool to compare those results with your "QC with database search" tool, which I'm aware uses X!Tandem as the search engine.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment