Support for AC3737/10 #118
Comments
You can install the |
Hi. Also have this one so it would be great to have it in HA. BTW appreciate the work.
|
I've started to provide the basics, please try release v0.18.7-3737-v1 You should be able to
The device is a new type so you have to help me to get it fully supported. I need you to go through all the settings, one after the other, and record the data in the same way as above. That way, we can see which data field is for what. Specifically, I need to understand
|
I can also see temperature, humidity and WIFI signal I will record more data and add it soon. |
Ok, great, that looks promising! For screen shots, you can simply capture the device page of HA that places all the items into certain sections. Once you have the data, I'll look at the rest. |
ok.
I gathered data after different commands, check attachments after_low_water.json let me know if any other configuration data needed. |
Amazing, thanks, let's see how far I can get |
please try v0.18.7-3737-v1 I think two things are still missing
Your data didn't really help identifying these. Can you please do four more data dumps where nothing changes, but only
|
Selection between humidifier and air purifier is strictly manual (you need to set water container on the device) but air+ app detects it. |
So with the container on top, you cannot switch humidification off? |
No, you can't switch off humidifier or purifier. Without water container options for humidify are just not available and in app you can see status of it as off. With it you have all options and you can see device status as 2in1. Light dimming works (little funny, because you have this slider but only 3 values works: 100, 50 and 0) |
Ok, so we need to figure out which data field shows the container to be on top. There is nothing on the HA side that limits the light dimming values, they can be 0 - 100. So what happens, if you set it to, say, 35? Nothing? Do I need to hardwire it to 0, 50, 100? |
I can set it, but value is still 100% until I go down to 50%. Then it's still 50% until 0. But that's ok it's the same how it works via air+ |
I'll leave it as is then. Do you have the extra data? |
Sorry for a delay, busy week. Files are time ordered, I hope name explains what is going on. nocommand_purifier.json |
Hey there 👋 is there any update on this? Would love to get this model supported. Is there any way I may help? |
apologies, just need to find time to analyze above data. |
No need to apologise at all 🙏 |
Sorry that this is so slow. Quick question: what is the difference between In the data, I see that the field My interpretation is, that |
In a way that's consistent with other models where this field is used to switch a mode. However, here it is just a sensor as the switch, as you say, is only manual. So that requires a little bit of rework as I need to introduce a new sensor that is only a sensor for this specific model.
This field in other models indicates a fan speed. I'll ignore this for now.
This field in other models indicates the preferred index to show, like pm2.5 or IAI or humidity. Could it be the same here, that 6 indicates that the preferred index changes to humidity automatically when you put the container on top, and then reverts to pm2.5 when you take it off again?
I have not seen this field being in use in any other model yet. Maybe you can play around with your preferred index settings and see if that has any effect on this field as well. If not, I'll just ignore it.
This seems to be the only field indicating that the container is out of water. I think I have seen this field before but the integration doesn't properly make use if it yet. I think it is a generic error field. So I wonder if I can simply test against the number 49408 to find out if the container has run out of water, or if this changes if there is more than error, like the filter need to be cleaned as well. In binary, the 49408 is |
Yes, interestingly enough, the Purifier works differently when the top container is attached or not. Just if this extra sentence helps in any way |
I could also try to provide that. Whenever this happens, of course. |
Ok, just checked with my own AC2729 which has a humidifier built-in as well. It also sets bit 9 when the tank is empty (of a different error field though), but it's probably fair to assume that bit 9 indicates the empty state. |
For what I've understood on this model it can operate without the Humidifier part. (You can completely detach the tank which is just sitting on top) and it will still run. I also noticed that if I set the fan to max speed (i.e. turbo) but the humidifier is there, it won't go to that fan speed. Only if I detach the humidifier OR if the PM2.5 level goes poor (like air quality gets poor) |
I've added two sensors now for water out error and to detect if humidification is active. Please give: v0.18.7-3737-v3 a spin. What else is missing? |
Not sure. Afaik for me with v2, things are working fine :) I'll upgrade the package to v3 and I'll report if things are working fine :) |
Can I just check with everybody if all functionality works as expected, sensors are working and nothing is missing that you have in the Philips app? I'd like to release this. |
Everything is working for me! |
Thank you for making this, @kongo09 !! |
I've started to experiment with the
Can someone here please take another look? If we cannot conclude, I'll just pick one... |
You can track progress at #198 |
If introduced a new |
Hello. Can u add the AC3737/10 please?
How i create this Python Enviroment? Directly in Home Assistant or Somewhere else. So i can support with Data maybe.
The text was updated successfully, but these errors were encountered: