When I run xQSM as the dipole inversion step, I get the following error:
The following QSM algorithm will be used: xQSM
Warning: Name is nonexistent or not a directory:
/home/common/matlab/sepia/external/deepMRI/xQSM/matlab/eval
In path (line 109)
In addpath (line 86)
In Wrapper_QSM_xQSM (line 39)
In QSMMacro (line 108)
In SepiaIOWrapper (line 327)
In sepiaIO (line 79)
In sepia_config_56 (line 38)
In run (line 91)
In sepia>PushbuttonStart_Callback (line 353)
Warning: Name is nonexistent or not a directory:
/home/common/matlab/sepia/external/deepMRI/xQSM_data/checkpoints
In path (line 109)
In addpath (line 86)
In Wrapper_QSM_xQSM (line 40)
In QSMMacro (line 108)
In SepiaIOWrapper (line 327)
In sepiaIO (line 79)
In sepia_config_56 (line 38)
In run (line 91)
In sepia>PushbuttonStart_Callback (line 353)
There was an error! Please check the command window/error message file for more information.
Unrecognized function or variable 'field'.
Error in Wrapper_QSM_xQSM (line 50)
[localField, pos] = ZeroPadding(field, 8);
Error in QSMMacro (line 108)
chi = feval(wrapper_QSM_function{k},localField,mask,matrixSize_new,voxelSize,algorParam, headerAndExtraData);
Error in SepiaIOWrapper (line 327)
[chi,mask_ref] = QSMMacro(localField,mask_QSM,matrixSize,voxelSize,algorParam,headerAndExtraData);
Error in sepiaIO (line 79)
SepiaIOWrapper(input,output,maskFullName,algorParam);
Error in sepia_config_56 (line 38)
sepiaIO(input,output_basename,mask_filename,algorParam);
Error in run (line 91)
evalin('caller', strcat(script, ';'));
Error in sepia>PushbuttonStart_Callback (line 353)
run(configFilename);
Error while evaluating UIControl Callback.
Do I need to install another toolbox to use this method?
The text was updated successfully, but these errors were encountered:
When I run xQSM as the dipole inversion step, I get the following error:
The following QSM algorithm will be used: xQSM
Warning: Name is nonexistent or not a directory:
/home/common/matlab/sepia/external/deepMRI/xQSM/matlab/eval
Error in Wrapper_QSM_xQSM (line 50)
[localField, pos] = ZeroPadding(field, 8);
Error in QSMMacro (line 108)
chi = feval(wrapper_QSM_function{k},localField,mask,matrixSize_new,voxelSize,algorParam, headerAndExtraData);
Error in SepiaIOWrapper (line 327)
[chi,mask_ref] = QSMMacro(localField,mask_QSM,matrixSize,voxelSize,algorParam,headerAndExtraData);
Error in sepiaIO (line 79)
SepiaIOWrapper(input,output,maskFullName,algorParam);
Error in sepia_config_56 (line 38)
sepiaIO(input,output_basename,mask_filename,algorParam);
Error in run (line 91)
evalin('caller', strcat(script, ';'));
Error in sepia>PushbuttonStart_Callback (line 353)
run(configFilename);
Error while evaluating UIControl Callback.
Do I need to install another toolbox to use this method?
The text was updated successfully, but these errors were encountered: