You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
fan2go is unable to set the fan speed on my system
fancontrol and coolercontrol can do so just fine, enabling the corresponding services one-at-a-time.
But when I do sudo systemctl start fan2go, I get the log below from journalctl -u fan2go -f, repeating of course unless I stop the service.
I can also set values manually (as root) in /sys/class/hwmon/hwmon3/ by echoing to the pwm# files and the values stay how I set them. The fans respond accordingly.
Somehow just fan2go seems to be unable to set fan speed values.
OS: Manjaro latest
kernel: Linux 6.10.0-rc4-1-MANJARO #1 SMP PREEMPT_DYNAMIC Tue Jun 18 11:21:09 UTC 2024 x86_64 GNU/Linux
sensors: sensors version 3.6.0+git with libsensors version 3.6.0+git
fan2go: 0.8.1 (fan2go-git from AUR)
mainboard: MSI PRO Z690-A
module: nct6687d
journalctl -u fan2go -f
fan2go[3095]: INFO: Gathering sensor data for front_high...
fan2go[3095]: INFO: Loading fan curve data for fan 'front_low'...
fan2go[3095]: INFO: Loading fan curve data for fan 'front_high'...
fan2go[3095]: INFO: Loading fan curve data for fan 'cpu'...
fan2go[3095]: INFO: Loading fan curve data for fan 'back'...
fan2go[3095]: INFO: FanController: Using saved value for pwm map of Fan 'front_low'
fan2go[3095]: INFO: PWM settings of fan 'front_low': Min 180, Start 200, Max 255
fan2go[3095]: INFO: Starting controller loop for fan 'front_low'
fan2go[3095]: INFO: FanController: Using saved value for pwm map of Fan 'cpu'
fan2go[3095]: INFO: PWM settings of fan 'cpu': Min 0, Start 0, Max 129
fan2go[3095]: INFO: Starting controller loop for fan 'cpu'
fan2go[3095]: INFO: FanController: Using saved value for pwm map of Fan 'front_high'
fan2go[3095]: INFO: PWM settings of fan 'front_high': Min 0, Start 0, Max 0
fan2go[3095]: INFO: Starting controller loop for fan 'front_high'
fan2go[3095]: WARNING: Fan 'back' has not yet been analyzed, starting initialization sequence...
fan2go[3095]: INFO: FanController: Using saved value for pwm map of Fan 'back'
fan2go[3095]: INFO: Measuring RPM curve...
fan2go[3095]: WARNING: WARNING: Increasing minPWM of front_low from 0 to 1, which is supposed to never stop, but RPM is 0
fan2go[3095]: WARNING: PWM of cpu was changed by third party! Last set PWM value was: 58 but is now: 33
fan2go[3095]: WARNING: WARNING: Increasing minPWM of cpu from 0 to 1, which is supposed to never stop, but RPM is 0
fan2go[3095]: WARNING: PWM of cpu was changed by third party! Last set PWM value was: 58 but is now: 33
fan2go[3095]: WARNING: PWM of cpu was changed by third party! Last set PWM value was: 58 but is now: 33
fan2go[3095]: WARNING: PWM of cpu was changed by third party! Last set PWM value was: 58 but is now: 33
fan2go[3095]: WARNING: PWM of cpu was changed by third party! Last set PWM value was: 58 but is now: 0
fan2go[3095]: WARNING: PWM of cpu was changed by third party! Last set PWM value was: 58 but is now: 0
fan2go[3095]: WARNING: PWM of cpu was changed by third party! Last set PWM value was: 58 but is now: 0
fan2go[3095]: WARNING: PWM of cpu was changed by third party! Last set PWM value was: 58 but is now: 0
fan2go detect
> coretemp-isa-0000
Sensors Index Label Value
1 Package id 0 (temp1_input) 29000
2 Core 0 (temp2_input) 26000
3 Core 4 (temp6_input) 29000
4 Core 8 (temp10_input) 26000
5 Core 12 (temp14_input) 26000
6 Core 16 (temp18_input) 28000
7 Core 20 (temp22_input) 28000
8 Core 28 (temp30_input) 29000
9 Core 29 (temp31_input) 29000
10 Core 30 (temp32_input) 29000
11 Core 31 (temp33_input) 29000
> nvme-pci-0100
Sensors Index Label Value
1 Composite (temp1_input) 38850
2 Sensor 1 (temp2_input) 38850
3 Sensor 2 (temp3_input) 47850
> nct6687-isa-0a20
Fans Index Channel Label RPM PWM Auto
1 1 CPU Fan 0 33 false
2 2 Pump Fan 980 255 false
3 3 System Fan #1 0 153 false
4 4 System Fan #2 703 153 false
5 5 System Fan #3 619 153 false
6 6 System Fan #4 0 153 false
7 7 System Fan #5 0 153 false
8 8 System Fan #6 0 153 false
Sensors Index Label Value
1 CPU (temp1_input) 29000
2 System (temp2_input) 38500
3 VRM MOS (temp3_input) 32000
4 PCH (temp4_input) 58000
5 CPU Socket (temp5_input) 32500
6 PCIe x1 (temp6_input) 36000
7 M2_1 (temp7_input) 31500
> nvme-pci-0500
Sensors Index Label Value
1 Composite (temp1_input) 37850
2 Sensor 1 (temp2_input) 37850
3 Sensor 2 (temp3_input) 45850
/etc/fan2go/fan2go.yaml (validates fine):
fans:
# A user defined ID.
# Used for logging only
- id: cpu
hwmon:
platform: nct6687
rpmChannel: 1
pwmChannel: 1
neverStop: true
curve: cpu_curve
- id: back
hwmon:
platform: nct6687
rpmChannel: 2
pwmChannel: 2
neverStop: true
curve: cpu_curve
- id: front_low
hwmon:
platform: nct6687
rpmChannel: 3
pwmChannel: 3
neverStop: true
curve: cpu_curve
minPwm: 180
maxPwm: 255
startPwm: 200
- id: front_high
hwmon:
platform: nct6687
rpmChannel: 4
pwmChannel: 4
neverStop: true
curve: cpu_curve
sensors:
# A user defined ID, which is used to reference
# a sensor in a curve configuration (see below)
- id: cpu_package
# The type of sensor configuration, one of: hwmon | file | cmd
hwmon:
# A regex matching a controller platform displayed by `fan2go detect`, f.ex.:
# "coretemp", "it8620", "corsaircpro-*" etc.
platform: coretemp
# The index of this sensor as displayed by `fan2go detect`
index: 1
curves:
- id: cpu_curve
# The type of the curve, one of: linear | function
linear:
# The sensor ID to use as a temperature input
sensor: cpu_package
# Sensor input value at which the curve is at minimum speed
min: 25
# Sensor input value at which the curve is at maximum speed
max: 60
The text was updated successfully, but these errors were encountered:
Oct 20 09:56:19 grover fan2go[937]: INFO: PWM settings of fan 'top': Min 95, Start 105, Max 255
Oct 20 09:56:19 grover fan2go[937]: INFO: Starting controller loop for fan 'top'
Oct 20 09:56:19 grover fan2go[937]: INFO: Computing pwm map...
Oct 20 09:56:21 grover fan2go[937]: INFO: PWM settings of fan 'front1': Min 50, Start 85, Max 255
Oct 20 09:56:21 grover fan2go[937]: INFO: Starting controller loop for fan 'front1'
Oct 20 09:56:21 grover fan2go[937]: INFO: Computing pwm map...
Oct 20 09:56:21 grover fan2go[937]: WARNING: WARNING: Increasing minPWM of top from 0 to 1, which is supposed to never stop, but RPM is 0
Should fan2go not set the minPWM back to the 95 I have in the config? (this is with fan2go-git built 20 Oct).
fan2go is unable to set the fan speed on my system
fancontrol and coolercontrol can do so just fine, enabling the corresponding services one-at-a-time.
But when I do
sudo systemctl start fan2go
, I get the log below fromjournalctl -u fan2go -f
, repeating of course unless I stop the service.I can also set values manually (as root) in /sys/class/hwmon/hwmon3/ by echoing to the pwm# files and the values stay how I set them. The fans respond accordingly.
Somehow just fan2go seems to be unable to set fan speed values.
OS: Manjaro latest
kernel: Linux 6.10.0-rc4-1-MANJARO #1 SMP PREEMPT_DYNAMIC Tue Jun 18 11:21:09 UTC 2024 x86_64 GNU/Linux
sensors: sensors version 3.6.0+git with libsensors version 3.6.0+git
fan2go: 0.8.1 (fan2go-git from AUR)
mainboard: MSI PRO Z690-A
module: nct6687d
journalctl -u fan2go -f
fan2go detect
/etc/fan2go/fan2go.yaml (validates fine):
The text was updated successfully, but these errors were encountered: