Notifications
You must be signed in to change notification settings - Fork 4
/
config.py
133 lines (118 loc) · 5.82 KB
/
config.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
config = {
'meterhub_address': 'http://192.168.0.10:8008',
'victron_mk3_port': '/dev/serial/by-id/usb-VictronEnergy_MK3-USB_Interface_HQ2132VK4JK-if00-port0',
# use 'bms_us2000' for US2000 or US3000 and 'bms_us5000' for US5000
'bms_us2000': {
'port': "/dev/serial/by-path/platform-3f980000.usb-usb-0:1.3:1.0", # Raspberry Home (rechts oben)
'pack_number': 2, # number of Pylontech packs
'baudrate': 115200, # Baudrate for Pylontech BMS
},
# 'bms_seplos': {
# 'port': "",
# ...
# },
'password': '1234', # Password for web access
'http_port': 8888, # HTTP port of the webserver
'www_path': "www", # path for static webserver files
'log_path': "log", # log path
# the blackbox stores the specified number of records in /log/blackbox-*.jsonl in case of error
'blackbox_size': 80, # Number of data sets, storage time: n * 750ms
'enable_car': True, # Show car values on dashboard
'enable_heat': False, # Show heater values on dashboard
'udc_max': 54, # maximum voltage (only checked at BMS, MP2 has peaks ?! ToDo !!!)
't_max': 40, # maximum temperature
# The setting [0] is used as default, undefined values from other settings [1, ...] are used from the setting [0]
'setting': [
{
'name': 'Standard',
'charge_min_power': 300, # [W] lowest charge power
'charge_max_power': 1000, # [W] highest charge power
'charge_reserve_power': 200, # [W] "distance" to excess power
'charge_end_soc': 95, # [%] SOC at which charging is finished
'charge_hysteresis_soc': 3, # [%] SOC restart hysteresis
'charge_end_voltage': 52, # [V] Voltage at which the charge is terminated
'charge_start_time': 30, # [s] Time in which the start condition for the load must exist
'charge_stop_time': 30, # [s] Delay time in charging mode without charging
'feed_min_power': 40, # [W] Minimum feed power
'feed_max_power': 2000, # [W] Maximum feed power
'feed_soc25_max_power': 1500, # [W] Maximum feed power below 25% SOC
'feed_reserve_power': 30, # [W] "Distance" consumption to feed-in power
'feed_end_soc': 10, # [%] SOC at which feed-in is terminated
'feed_hysteresis_soc': 5, # [%] SOC restart hysteresis
'feed_end_voltage': 47.0, # [V] Voltage at which the feed is terminated
'feed_start_time': 30, # [s] Time in which the start condition for the feed must exist
'feed_stop_time': 30, # [s] Delay time in feed-in operation without feed-in
'feed_throttle_time': 5 * 60, # [s] longer feeds in one piece are limited
'feed_throttle_power': 1500, # [W] Performance limit with throttling
'idle_sleep_time': 10 * 60, # [s] Sleeptimer, (idle --> sleep) Multiplus
},
{
'name': 'Maximal-Entladen (Sommer)',
'feed_max_power': 2400,
'feed_reserve_power': 10,
'feed_start_time': 10,
'feed_stop_time': 5,
},
{
'name': 'Maximal-Laden (Winter)',
'charge_min_power': 200,
'charge_max_power': 1600,
'charge_reserve_power': 25,
'charge_start_time': 10,
'charge_stop_time': 5,
'feed_soc25_max_power': 750,
},
{
'name': 'Nur Laden',
'charge_min_power': 200,
'charge_max_power': 1600,
'charge_reserve_power': 25,
'charge_start_time': 10,
'charge_stop_time': 5,
'feed_end_soc': 150, # never start feeding
},
{
'name': 'Max-Laden / 20% Reserve',
'charge_min_power': 200,
'charge_max_power': 1600,
'charge_reserve_power': 25,
'charge_start_time': 10,
'charge_stop_time': 5,
'feed_soc25_max_power': 750,
'feed_max_power': 1000, # [W] Maximum feed power
'feed_reserve_power': 50, # [W] "Distance" consumption to feed-in power
'feed_end_soc': 20, # [%] SOC at which feed-in is terminated
'feed_hysteresis_soc': 10, # [%] SOC restart hysteresis
},
{
'name': 'Full 100% Charge',
'charge_min_power': 200,
'charge_max_power': 500,
'charge_reserve_power': 50,
'charge_end_voltage': 53.75, # [V] Voltage at which the charge is terminated
'charge_start_time': 10,
'charge_stop_time': 5,
'charge_end_soc': 105, # [%] SOC at which charging is finished
'charge_hysteresis_soc': 2, # [%] SOC restart hysteresis
'feed_soc25_max_power': 750,
'feed_max_power': 1000, # [W] Maximum feed power
'feed_reserve_power': 50, # [W] "Distance" consumption to feed-in power
'feed_end_soc': 20, # [%] SOC at which feed-in is terminated
'feed_hysteresis_soc': 10, # [%] SOC restart hysteresis
}
],
# enable csv log
'csv_log': {'interval': 60, # storage interval in seconds
'columns': [ # first entry is the name, second and so on the route inside main dataset /api/state
('time', 'ess', 'time'),
('state', 'ess', 'state'),
('bat_ac_p', 'meterhub', 'bat_p'),
('mp2_bat_u', 'multiplus', 'bat_u'),
('mp2_bat_i', 'multiplus', 'bat_i'),
('bms_u0', 'bms', 'pack_u', 0),
('bms_u1', 'bms', 'pack_u', 1),
('bms_i0', 'bms', 'pack_i', 0),
('bms_i1', 'bms', 'pack_i', 1),
('bms_soc0', 'bms', 'pack_soc', 0),
('bms_soc1', 'bms', 'pack_soc', 1)]},
}