| 1 | +#!/bin/sh |
| 2 | + |
| 3 | +set -e |
| 4 | + |
| 5 | +: << =cut |
| 6 | +
|
| 7 | +=head1 NAME |
| 8 | +
|
| 9 | +arcconf - Monitor RAID adapters, logical devices and physical disks with arcconf |
| 10 | +
|
| 11 | +=head1 APPLICABLE SYSTEMS |
| 12 | +
|
| 13 | +Raid adapters managed with arcconf |
| 14 | +
|
| 15 | +=head1 CONFIGURATION |
| 16 | +
|
| 17 | + With "arcconf list" you find available controllers. Link arcconf_ with |
| 18 | + specified controller id. |
| 19 | + |
| 20 | + ln -s /usr/share/munin/plugins/arcconf_ /etc/munin/plugins/arcconf_1 |
| 21 | +
|
| 22 | + arcconf_bin - Path to arcconf binary |
| 23 | +
|
| 24 | + [arcconf_*] |
| 25 | + user root |
| 26 | + env.arcconf_bin /usr/local/sbin/arcconf |
| 27 | + |
| 28 | + [arcconf_1] |
| 29 | + env.min_online_disks 12 # Miniaml online disks |
| 30 | + env.max_adapter_temp 50 # Adapter temperature threshold |
| 31 | + |
| 32 | +=head1 AUTHOR |
| 33 | +
|
| 34 | +Copyright (C) 2020 Sebastian L. (https://momou.ch) |
| 35 | +
|
| 36 | +=head1 LICENSE |
| 37 | +
|
| 38 | +GPLv2 |
| 39 | +
|
| 40 | +=head1 MAGIC MARKERS |
| 41 | +
|
| 42 | + #%# family=auto |
| 43 | + #%# capabilities=autoconf |
| 44 | +
|
| 45 | +=cut |
| 46 | + |
| 47 | +. "$MUNIN_LIBDIR/plugins/plugin.sh" |
| 48 | + |
| 49 | +if [ "${MUNIN_DEBUG:-0}" = 1 ]; then |
| 50 | + set -x |
| 51 | +fi |
| 52 | + |
| 53 | +arcconf_bin="${arcconf_bin:-/usr/local/sbin/arcconf}" |
| 54 | +adapter_id="${0##*arcconf_}" |
| 55 | + |
| 56 | +ARCCONF=$($arcconf_bin getconfig "$adapter_id") |
| 57 | +ARCCONF_DISKS=$(echo "$ARCCONF" | grep -Pzo 'Device\ #(.|\n)*Service Hours.*[0-9]{1,6}' | tr '\0' '\n') |
| 58 | +ARCCONF_LOGICALDISKS=$(echo "$ARCCONF" | grep -Pzo 'Logical Device number (.|\n)*Parity Initialization Status' | tr '\0' '\n') |
| 59 | +ARCCONF_SMARTSTATS=$($arcconf_bin getsmartstats "$adapter_id") |
| 60 | + |
| 61 | +logicaldisks=$(echo "$ARCCONF_LOGICALDISKS" | grep -oE 'Logical Device number [0-9]+' | sed 's/Logical Device number //g') |
| 62 | +disks=$(echo "$ARCCONF_DISKS" | grep -oE 'Device #[0-9]+' | sed 's/Device #//g') |
| 63 | + |
| 64 | +case $1 in |
| 65 | + |
| 66 | + autoconf) |
| 67 | + if [ -x "$arcconf_bin" ]; then |
| 68 | + if [ -z "$(command -v arcconf)" ]; then |
| 69 | + echo "no (arcconf not found)" |
| 70 | + exit 0 |
| 71 | + else |
| 72 | + echo "yes" |
| 73 | + exit 0 |
| 74 | + fi |
| 75 | + else |
| 76 | + echo "no (/usr/local/sbin/arcconf not found)" |
| 77 | + exit 0 |
| 78 | + fi |
| 79 | + ;; |
| 80 | + |
| 81 | + config) |
| 82 | + adaptername=$(echo "$ARCCONF" | grep "Controller Model" | cut -d ":" -f 2 | xargs) |
| 83 | + |
| 84 | + echo "multigraph arcconf_${adapter_id}_logicaldisks" |
| 85 | + echo "graph_title arcconf_${adapter_id} - Status of logical disks" |
| 86 | + echo "graph_info arcconf_${adapter_id} - Status of logical disks on $adaptername adapter" |
| 87 | + echo "graph_args -u 1 -l 0" |
| 88 | + echo "graph_category disk" |
| 89 | + echo "graph_vlabel Online status" |
| 90 | + for logicaldisk in $logicaldisks; do |
| 91 | + raid_level=$(echo "$ARCCONF_LOGICALDISKS" | cut -d ":" -f 2 | xargs) |
| 92 | + echo "status_logicaldisk_$logicaldisk.label Logical disk $logicaldisk (raid $raid_level) status is optimal" |
| 93 | + echo "status_logicaldisk_$logicaldisk.info Status of logical disk $logicaldisk (raid $raid_level) is optimal" |
| 94 | + echo "status_logicaldisk_$logicaldisk.min 0" |
| 95 | + echo "status_logicaldisk_$logicaldisk.warning 1:" |
| 96 | + done |
| 97 | + |
| 98 | + echo "multigraph arcconf_${adapter_id}_online_disks" |
| 99 | + echo "graph_title arcconf_${adapter_id} - Online disks" |
| 100 | + echo "graph_info arcconf_${adapter_id} - Online disks on $adaptername adapter" |
| 101 | + echo "graph_args -A -l 0" |
| 102 | + echo "graph_category disk" |
| 103 | + echo "graph_vlabel Number of disks" |
| 104 | + echo "online_disks.label Online disks" |
| 105 | + echo "online_disks.info Current number of online disks on $adaptername adapter" |
| 106 | + echo "online_disks.min 0" |
| 107 | + if [ -n "${min_online_disks}" ]; then |
| 108 | + echo "online_disks.warning $min_online_disks:" |
| 109 | + fi |
| 110 | + |
| 111 | + echo "multigraph arcconf_${adapter_id}_temp" |
| 112 | + echo "graph_title arcconf_${adapter_id} - Temperature of adapter" |
| 113 | + echo "graph_info arcconf_${adapter_id} - Temperature of $adaptername adapter" |
| 114 | + echo "graph_args -Y -A -l 0" |
| 115 | + echo "graph_category disk" |
| 116 | + echo "graph_vlabel C" |
| 117 | + echo "adapter_temp.label Adapter temperature" |
| 118 | + echo "adapter_temp.info Current $adaptername adapter temperature" |
| 119 | + echo "adapter_temp.min 0" |
| 120 | + if [ -n "${max_adapter_temp}" ]; then |
| 121 | + echo "adapter_temp.warning $max_adapter_temp" |
| 122 | + fi |
| 123 | + |
| 124 | + echo "multigraph arcconf_${adapter_id}_disks_temp" |
| 125 | + echo "graph_title arcconf_${adapter_id} - Temperature of disks on adapter" |
| 126 | + echo "graph_info arcconf_${adapter_id} - Temperature of disks on adapter $adaptername" |
| 127 | + echo "graph_args -Y -A -l 0" |
| 128 | + echo "graph_category disk" |
| 129 | + echo "graph_vlabel C" |
| 130 | + for disk in $disks; do |
| 131 | + echo "temp_disk_$disk.label Temperature of disk $disk" |
| 132 | + echo "temp_disk_$disk.info Temperature of disk $disk" |
| 133 | + echo "temp_disk_$disk.min 0" |
| 134 | + done |
| 135 | + |
| 136 | + echo "multigraph arcconf_${adapter_id}_disks_usage" |
| 137 | + echo "graph_title arcconf_${adapter_id} - Remaining usage of disks" |
| 138 | + echo "graph_info arcconf_${adapter_id} - Remaining usage of disks in percent on adapter $adaptername" |
| 139 | + echo "graph_args -u 100 -l 0" |
| 140 | + echo "graph_category disk" |
| 141 | + echo "graph_vlabel %" |
| 142 | + for disk in $disks; do |
| 143 | + echo "remaining_usage_disk_$disk.label Remaining usage on disk $disk" |
| 144 | + echo "remaining_usage_disk_$disk.info Remaining usage on disk $disk" |
| 145 | + echo "remaining_usage_disk_$disk.min 0" |
| 146 | + echo "remaining_usage_disk_$disk.warning 80:" |
| 147 | + done |
| 148 | + |
| 149 | + for disk in $disks; do |
| 150 | + echo "multigraph arcconf_${adapter_id}_disk_${disk}" |
| 151 | + echo "graph_title arcconf_${adapter_id} - Disk $disk" |
| 152 | + echo "graph_info arcconf_${adapter_id} - Error counters of disk $disk on adapter $adaptername" |
| 153 | + echo "graph_args -Y -A -l 0" |
| 154 | + echo "graph_category disk" |
| 155 | + echo "graph_vlabel Errors" |
| 156 | + error_counters=$(echo "$ARCCONF" | sed -n "/Device #$disk/,/Device #/ p" | grep -Pzo 'Aborted(.|\n)*Scsi Bus Faults.*[0-9]{1,6}' | tr '\0' '\n') |
| 157 | + echo "$error_counters" | while read -r error_counter; do |
| 158 | + name=$(echo "$error_counter" | sed -n 's/\([[:alpha:] ]*\).*/\1/p' | sed 's/ *$//g') |
| 159 | + if [ -n "$name" ]; then |
| 160 | + name=$(clean_fieldname "$name") |
| 161 | + key="${name}_${disk}" |
| 162 | + echo "$key.label $name" && echo "$key.info $name" && echo "$key.min 0" |
| 163 | + # Sparse disks are "not ready", so don't warn |
| 164 | + echo "$name" | grep -q "Not_Ready_Error" || echo "$key.critical 1" |
| 165 | + fi |
| 166 | + done |
| 167 | + done |
| 168 | + |
| 169 | + for disk in $disks; do |
| 170 | + echo "multigraph arcconf_${adapter_id}_smartstats_${disk}" |
| 171 | + echo "graph_title arcconf_${adapter_id} - S.M.A.R.T values disk $disk" |
| 172 | + echo "graph_vlabel Attribute S.M.A.R.T value" |
| 173 | + echo "graph_args -u 100 -l 0" |
| 174 | + echo "graph_category disk" |
| 175 | + echo "graph_info This graph shows the value of all S.M.A.R.T attributes of disk $disk." |
| 176 | + smartstats=$(echo "$ARCCONF_SMARTSTATS" | sed -n "/\<PhysicalDriveSmartStats channel=\"[[:digit:]]\" id=\"$disk\"/,/\/PhysicalDriveSmartStats\>/ p") |
| 177 | + echo "$smartstats" | while read -r attribute; do |
| 178 | + name=$(echo "$attribute" | sed -n 's/.*name="\([[:alnum:] ()-/]*\)\".*/\1/p') |
| 179 | + if [ -n "$name" ]; then |
| 180 | + name=$(clean_fieldname "$name") |
| 181 | + key="${name}_${disk}" |
| 182 | + echo "$key.label $name" && echo "$key.info $name" && echo "$key.min 0" |
| 183 | + threshold=$(echo "$attribute" | sed -n 's/.*thresholdValue="\([[:digit:]]*\).*/\1/p') |
| 184 | + [ "$threshold" ] && echo "$key.critical $threshold:" |
| 185 | + fi |
| 186 | + done |
| 187 | + done |
| 188 | + |
| 189 | + exit 0 |
| 190 | + |
| 191 | + ;; |
| 192 | + |
| 193 | +esac |
| 194 | + |
| 195 | +echo "multigraph arcconf_${adapter_id}_logicaldisks" |
| 196 | +for logicaldisk in $logicaldisks; do |
| 197 | + status=$(echo "$ARCCONF" | sed -n "/Logical Device number $logicaldisk/,/Parity Initialization Status/ p" | grep 'Status of Logical Device' | grep -c 'Optimal') |
| 198 | + [ "$status" ] || status="U" |
| 199 | + echo "status_logicaldisk_$logicaldisk.value $status" |
| 200 | +done |
| 201 | + |
| 202 | +echo "multigraph arcconf_${adapter_id}_online_disks" |
| 203 | +online_disks=$(echo "$ARCCONF" | grep -cE 'State.*: Online') |
| 204 | +[ "$online_disks" ] || online_disks="U" |
| 205 | +echo "online_disks.value $online_disks" |
| 206 | + |
| 207 | +echo "multigraph arcconf_${adapter_id}_temp" |
| 208 | +adapter_temp=$(echo "$ARCCONF" | grep -oE "Temperature[\ ]+:\ [0-9]{1,3} C\/" | grep -oE '[0-9]+') |
| 209 | +[ "$adapter_temp" ] || adapter_temp="U" |
| 210 | +echo "adapter_temp.value $adapter_temp" |
| 211 | + |
| 212 | +echo "multigraph arcconf_${adapter_id}_disks_temp" |
| 213 | +for disk in $disks; do |
| 214 | + disk_temp=$(echo "$ARCCONF" | sed -n "/Device #$disk/,/Device #/ p" | grep 'Current Temperature' | grep -oE '[0-9]+') |
| 215 | + [ "$disk_temp" ] || disk_temp="U" |
| 216 | + echo "temp_disk_$disk.value $disk_temp" |
| 217 | +done |
| 218 | + |
| 219 | +echo "multigraph arcconf_${adapter_id}_disks_usage" |
| 220 | +for disk in $disks; do |
| 221 | + usage=$(echo "$ARCCONF" | sed -n "/Device #$disk/,/Device #/ p" | grep 'Usage Remaining' | grep -oE '[0-9]+') |
| 222 | + [ "$usage" ] || usage="U" |
| 223 | + echo "remaining_usage_disk_$disk.value $usage" |
| 224 | +done |
| 225 | + |
| 226 | +for disk in $disks; do |
| 227 | + echo "multigraph arcconf_${adapter_id}_disk_${disk}" |
| 228 | + error_counters=$(echo "$ARCCONF" | sed -n "/Device #$disk/,/Device #/ p" | grep -Pzo 'Aborted(.|\n)*Scsi Bus Faults.*[0-9]{1,6}' | tr '\0' '\n') |
| 229 | + echo "$error_counters" | while read -r error_counter; do |
| 230 | + name=$(echo "$error_counter" | sed -n 's/\([[:alpha:] ]*\).*/\1/p' | sed 's/ *$//g') |
| 231 | + if [ -n "$name" ]; then |
| 232 | + name=$(clean_fieldname "$name") |
| 233 | + key="${name}_${disk}" |
| 234 | + value=$(echo "$error_counter" | grep -oE '[0-9]+') |
| 235 | + [ "$value" ] || value="U" |
| 236 | + echo "$key.value $value" |
| 237 | + fi |
| 238 | + done |
| 239 | +done |
| 240 | + |
| 241 | +for disk in $disks; do |
| 242 | + echo "multigraph arcconf_${adapter_id}_smartstats_${disk}" |
| 243 | + smartstats=$(echo "$ARCCONF_SMARTSTATS" | sed -n "/\<PhysicalDriveSmartStats channel=\"[[:digit:]]\" id=\"$disk\"/,/\/PhysicalDriveSmartStats\>/ p") |
| 244 | + echo "$smartstats" | while read -r attribute; do |
| 245 | + name=$(echo "$attribute" | sed -n 's/.*name="\([[:alnum:] ()-/]*\)\".*/\1/p') |
| 246 | + if [ -n "$name" ]; then |
| 247 | + name=$(clean_fieldname "$name") |
| 248 | + key="${name}_${disk}" |
| 249 | + value=$(echo "$attribute" | sed -n 's/.*normalizedCurrent="\([[:digit:]]*\).*/\1/p') |
| 250 | + [ "$value" ] || value="U" |
| 251 | + echo "$key.value $value" |
| 252 | + fi |
| 253 | + done |
| 254 | +done |