Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathtrans_cap.m
More file actions
113 lines (96 loc) · 5.3 KB
/
trans_cap.m
File metadata and controls
113 lines (96 loc) · 5.3 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
%% trans_cap.m
% This function allows the user to grab a fixed length of data from the UUT.
%
% A transient command is sent to the System Controller (Port 4220). Once the value of
% shot_complete increments by one, data is ready to be pulled from Ports 53001:530XX.
%
% Arguments to the function are as follows :
%
% <html>
% <table border=1><tr>
% <td> Argument </td><td> Description </td></tr><tr>
% <td><b> card </b></td><td> Type of D-TACQ acquistition card in system. 'acq435', 'acq437', 'acq420', 'acq425' </td></tr><tr>
% <td><b> pre </b></td><td> For use with pre/post EVENT mode. Number of samples to record prior to trigger. Should be zero if not in EVENT mode. </td></tr><tr>
% <td><b> post </b></td><td> Number of samples after trigger for EVENT mode. For other modes this is effectively total number of samples. </td></tr><tr>
% <td><b> ch_mask </b></td><td> Channel mask. This can be a scalar or vector. </td></tr><tr>
% <td> - </td><td> SCALAR : capture will record channels corresponding to 1:ch_mask </td></tr><tr>
% <td> - </td><td> VECTOR : capture will record channels specified in mask, e.g. [1,2,5,10] will record channels CH01,CH02,CH05 & CH10 </td></tr><tr>
% <td><b> trig </b></td><td> Trigger source. Select from 'soft', 'hard' or 'event'. </td></tr><tr>
% <td> - </td><td> soft - Internal software trigger </td></tr><tr>
% <td> - </td><td> hard - External hardware trigger </td></tr><tr>
% <td> - </td><td> event - External hardware trigger with support for pre/post capture </td></tr><tr>
% <td><b> rate </b></td><td> Sampling rate in Hz. The program will warn the user if this is outside supported clock limits </td></tr></table>
% </html>
%
% The maximum number of samples which can be pulled is *1,000,000*.
% Maximum number of PRE samples is : *4096* for a 64CH system, *2730* for a 96CH system.
%
%%
function trans_cap(card,pre,post,ch_mask,trig,rate)
%tic
global UUT %Make base workspace variable visible in function
done = 0;
% Check that Carrier has completed boot
result = boot_complete();
if result == 0; return; end;
disp(UUT)
set_sample_rate(1,card,rate); % Set up sampling rate
[resolution,variable_gain] = get_res(card);
vsf = calc_vsf(resolution,variable_gain); % Voltage Scaling Factor
% Catch errors
if strcmp(trig,'event') == 0
if pre > 0; fprintf(2,'PRE is greater than ZERO. This is only valid in EVENT mode!\n'); pre=0; end
if post > 1000000; fprintf(2,'POST is greater than 1,000,000! Please reduce number of samples and try again...\n'); return; end
else
if (pre + post) > 40000; fprintf(2,'In EVENT mode PRE + POST must be < 40000. Too many samples requested!\n'); return; end
if pre > 2730; fprintf(2,'PRE is greater than 2730! This is the maximum for a 96CH system...\n'); end
if pre > 4096; fprintf(2,'PRE is greater than 4096! This is the maximum for a 64CH system...\n'); end
end
num_samp = pre + post;
% Special option for contiguous 1:ch_mask channels
if length(ch_mask) == 1
ch_mask = [1:ch_mask];
end
% Configure port and open
ID = tcpip(UUT,4220); % 4220 = System Controller
ID.terminator = 10; % ASCII line feed
ID.InputBufferSize = 100;
ID.Timeout = 5;
fopen(ID);
% Query the value of shot_complete on UUT
command = 'shot_complete';
fprintf(ID,command);
shotc_before = fscanf(ID); % Map response of query to 'shotc_before'
shotc_before = str2double(shotc_before);
%disp(shotc_before)
% Set up trigger source, request transient and arm
transient_commands(1,trig,post,pre);
% Monitor log port for TRIGGER and POST/STOP
monitor_log;
% Poll shot_complete
% Map result to shotc_after. When it increments, and shotc_after is
% one greater than shotc_before loop breaks.
command = 'shot_complete';
while true
fprintf(ID,command);
shotc_after = fscanf(ID);
shotc_after = str2double(shotc_after);
if (shotc_after > shotc_before)
fprintf('\n...Transient Capture Complete...\n\n');
break
end
end
fclose(ID);
delete(ID);
% Pull transient data from channels 53001:530XX
% Store results in cell array indexed 1:XX
fetch_data(ch_mask,resolution,num_samp);
% Catch data timeout
if findstr('Unsuccessful read',lastwarn)
lastwarn('');
fetch_data(ch_mask,resolution,num_samp);
end
% Plot in a figure and enable plotting controls
plot_data(ch_mask,vsf,num_samp);
%toc
end