when the invoice is pasted and it's wrong there's an error written to the log but not provided to the user. Actually the log is pretty clear saying "Must include only alpha numeric characters", this message should be presented to the user in red text near the field that contains the error.
Reproduce
Log into Citadel
click Lightning
click Send
paste an invoice that contains a space in it. Animation of a line moving back and forth will occur with no feedback about what is wrong.
Citadel version
0.1.3
Operating system
Debian
Log output
middleware | InternalServerError: Must include only alpha numeric characters.
middleware | at Object.throw (/app/node_modules/koa/lib/context.js:97:11)
middleware | at Module.isAlphanumeric (file:///app/node_modules/@runcitadel/utils/lib/typeHelper.js:15:18)
middleware | at file:///app/routes/v1/lnd/lightning.js:45:16
middleware | at dispatch (/app/node_modules/koa-compose/index.js:42:32)
middleware | at file:///app/middlewares/auth.js:44:15
middleware | at process.processTicksAndRejections (node:internal/process/task_queues:95:5)
The text was updated successfully, but these errors were encountered:
it was actually a newline character that when pasting got turned into a space (showed as %20 in GET /api/v1/lnd/lightning/invoice?paymentRequest=). actually I don't know if the BOLTs say you need to support multi-line invoices but that would make some kind of sense, maybe the wallet should merge the lines together if this happens, but that might be more complicated to implement and an error would have worked for me.