Updated autogain section to reflect correct default values as presented in the following files:
- rootfs/usr/local/bin/autogain978
- rootfs/scripts/autogain.sh
Co-authored-by: kx1t <[email protected]>
Copy file name to clipboardExpand all lines: README.md
+6-6Lines changed: 6 additions & 6 deletions
Display the source diff
Display the rich diff
Original file line number
Diff line number
Diff line change
@@ -347,13 +347,13 @@ These variables control the autogain system (explained further below). These sho
347
347
348
348
| Variable | Description | Default |
349
349
|----------|-------------|---------|
350
-
| `DUMP978_AUTOGAIN_INITIAL_TIMEPERIOD` | How long the autogain initialization phase should take (ie: "roughing in"), in seconds. | `21600` (6 hours) |
351
-
| `DUMP978_AUTOGAIN_INITIAL_INTERVAL` | How often autogain should measure and adjust the gain during the initialization phase, in seconds. | `600` (10 minutes) |
350
+
| `DUMP978_AUTOGAIN_INITIAL_TIMEPERIOD` | How long the autogain initialization phase should take (ie: "roughing in"), in seconds. | `32400` (9 hours) |
351
+
| `DUMP978_AUTOGAIN_INITIAL_INTERVAL` | How often autogain should measure and adjust the gain during the initialization phase, in seconds. | `900` (15 minutes) |
352
352
| `DUMP978_AUTOGAIN_SUBSEQUENT_INTERVAL` | How often autogain should measure and adjust the gain after the initialization phase is done, in seconds. | `84600` (24 hours) |
353
353
| `DUMP978_AUTOGAIN_ADJUSTMENT_LIMITS` | If set to `true`/`on`/`yes`/`1`, while in the initialization phase, autogain will only adjust the gain during the timeframe set by the `DUMP978_AUTOGAIN_ADJUSTMENT_TIMEFRAME` parameter. | `true` |
354
354
| `DUMP978_AUTOGAIN_ADJUSTMENT_TIMEFRAME` | Timeframe limits for autogain during the initializaion phase, in `HHMM-HHMM` (start hours/minutes to end hours/minutes). If an adjustment "run" falls outside these limits, the autogain adjustment is delayed until the start of the next timeframe. Times are based on the container's Timezone (`TZ`) setting. | `0900-1800` (9 AM - 6 PM, local container time) |
355
-
| `DUMP978_AUTOGAIN_LOW_PCT` | If the percentage of "strong signals" (>3dB) over a measuring period is less than this parameter, the gain will be increased by 1 position | `2.5` (2.5%) |
356
-
| `DUMP978_AUTOGAIN_HIGH_PCT` | If the percentage of "strong signals" (>3dB) over a measuring period is more than this parameter, the gain will be decreased by 1 position | `6.0` (6.0%) |
355
+
| `DUMP978_AUTOGAIN_LOW_PCT` | If the percentage of "strong signals" (>3.5dB) over a measuring period is less than this parameter, the gain will be increased by 1 position | `5.0` (5.0%) |
356
+
| `DUMP978_AUTOGAIN_HIGH_PCT` | If the percentage of "strong signals" (>3.5dB) over a measuring period is more than this parameter, the gain will be decreased by 1 position | `10.0` (10.0%) |
357
357
| `READSB_AUTOGAIN_MIN_SAMPLES` | Minimum number of received samples for autogain to be able to consider adjusting the gain | `1000` |
358
358
| `READSB_AUTOGAIN_USE_RAW` | If set to `true`/`on`/`yes`/`1`, the autogain function will use the "raw" message count rather than the "accepted" message count. | `true` |
359
359
| `SUBSEQUENT_INTERVAL_MINIMUM_COMPLETION_PCT` | Minimum percentage of `DUMP978_AUTOGAIN_SUBSEQUENT_INTERVAL` time that needs to be completed before autogain will use the collected data during the subsequent/long-term process | `50` |
@@ -362,12 +362,12 @@ These variables control the autogain system (explained further below). These sho
362
362
363
363
An automatic gain adjustment system is included in this container, and can be activated by setting the environment variable `DUMP978_SDR_GAIN` to `autogain`. You should also map `/var/globe_history/` to persistent storage, otherwise the autogain system will start over each time the container is restarted.
364
364
365
-
Autogain will take several hours to initially work out a reasonable gain. This is the so-called "initialization period", which is by default 6 hours. It will then perform a daily measurement to see if your gain needs further adjusting.
365
+
Autogain will take several hours to initially work out a reasonable gain. This is the so-called "initialization period", which is by default 9 hours. It will then perform a daily measurement to see if your gain needs further adjusting.
366
366
367
367
The autogain system will work as follows; values are based on the default parameter settings from above:
368
368
369
369
1. `dump978` is set to maximum gain.
370
-
2. Initial results are collected every 10 minutes, for up to 6 hours (initialization phase). If `DUMP978_AUTOGAIN_ADJUSTMENT_LIMITS` is set to true, measurements are suspended if the time is outside the set time limits (0900 - 1800 local container time). Every 10 minutes, the gain is adjusted by 1 position if the average percentage of "strong" signals (>-3dB) is less than 2.5% or more than 6.0%.
370
+
2. Initial results are collected every 15 minutes, for up to 9 hours (initialization phase). If `DUMP978_AUTOGAIN_ADJUSTMENT_LIMITS` is set to true, measurements are suspended if the time is outside the set time limits (0900 - 1800 local container time). Every 15 minutes, the gain is adjusted by 1 position if the average percentage of "strong" signals (>-3.5dB) is less than 5.0% or more than 10.0%.
371
371
3. After the initialization phase is over, the average percentage of "strong signal" is calculated on a daily basis, and an adjustment is made accordingly.
0 commit comments