RF input level indication is stuck permanently at -82dBm.
Switching between A and B sockets makes no difference to the displayed amplitude, but the MER changes.
If, however the same switching is done using the Minitioune software the displayed amplitude changes between -20dBm and -67dBm.
Thanks for your work on this project.
Clive, G3GJA
The text was updated successfully, but these errors were encountered:
Hi Clive,
Thanks for reporting. I did some tests and you are correct. I'm working on a fix.
T
Sorry, something went wrong.
RF input level indication is stuck permanently at -82dBm. Switching between A and B sockets makes no difference to the displayed amplitude, but the MER changes. If, however the same switching is done using the Minitioune software the displayed amplitude changes between -20dBm and -67dBm. Thanks for your work on this project. Clive, G3GJA
Hi Brian,
I have fixed "RF level stuck at -82 dB" in source code. Fix shall be include in next release.
73 de Martin, DL1RF
No branches or pull requests
RF input level indication is stuck permanently at -82dBm.
Switching between A and B sockets makes no difference to the displayed amplitude, but the MER changes.
If, however the same switching is done using the Minitioune software the displayed amplitude changes between -20dBm and -67dBm.
Thanks for your work on this project.
Clive, G3GJA
The text was updated successfully, but these errors were encountered: