import logging
import struct
import sys
import time
from pathlib import Path
from umrx_app_v3.sensors.bmm350 import BMM350
from umrx_app_v3.shuttle_board.bmm350.bmm350_shuttle import BMM350Shuttle
def setup_logging(level: int = logging.DEBUG) -> logging.Logger:
logger = logging.getLogger()
logger.setLevel(level)
stdout_handler = logging.StreamHandler(sys.stdout)
log_format = "(%(asctime)s) [%(levelname)-8s] %(message)s"
log_formatter = logging.Formatter(log_format)
stdout_handler.setFormatter(log_formatter)
file_handler = logging.FileHandler(f"{Path(__file__).parent / Path(__file__).stem}.log", mode="w")
file_handler.setFormatter(log_formatter)
logger.addHandler(stdout_handler)
logger.addHandler(file_handler)
return logger
if __name__ == "__main__":
logger = setup_logging()
# This example is for Application Board 3.1 hardware
shuttle = BMM350Shuttle.on_hardware_v3_rev1()
shuttle.initialize()
shuttle.check_connected_hw()
shuttle.configure_i2c()
logger.info(f"chip_id=0x{shuttle.sensor.chip_id:04X}")
assert shuttle.sensor.chip_id == 0x33
_ = shuttle.sensor.compensate_magnetometer_and_temperature(0, 0, 0, 0) # cache OTP
shuttle.close_otp()
shuttle.configure_polling_streaming()
shuttle.start_streaming()
time.sleep(0.1)
for idx in range(1000):
for streaming in shuttle.board.receive_polling_streaming_multiple():
sensor_id, payload = streaming
(
m_x_xlsb,
m_x_lsb,
m_x_msb,
m_y_xlsb,
m_y_lsb,
m_y_msb,
m_z_xlsb,
m_z_lsb,
m_z_msb,
temp_xlsb,
temp_lsb,
temp_msb,
time_xlsb,
time_lsb,
time_msb,
) = struct.unpack("<xxBBBBBBBBBBBBBBB", payload)
m_x_raw = (m_x_msb << 16) | (m_x_lsb << 8) | m_x_xlsb
m_y_raw = (m_y_msb << 16) | (m_y_lsb << 8) | m_y_xlsb
m_z_raw = (m_z_msb << 16) | (m_z_lsb << 8) | m_z_xlsb
m_x_signed, m_y_signed, m_z_signed = BMM350.sign_convert_magnetometer(m_x_raw, m_y_raw, m_z_raw)
temp_raw = (temp_msb << 16) | (temp_lsb << 8) | temp_xlsb
temp_signed = BMM350.sign_convert_24_bit(temp_raw)
sensor_time = ((time_msb << 16) | (time_lsb << 8) | time_xlsb) * 39.0625e-6
m_x, m_y, m_z, temp = shuttle.sensor.compensate_magnetometer_and_temperature(
m_x_signed, m_y_signed, m_z_signed, temp_signed
)
logger.info(
f"[{idx=:03d}], magnetometer(uT)=(x={m_x:+3.3f}, y={m_y:+3.3f}, z={m_z:+3.3f}), "
f"temperature(C)={temp:.3f}, "
f"time_stamp(s)={sensor_time:.3f}"
)
time.sleep(0.05)
shuttle.board.stop_polling_streaming()