…ngs': false to meson.build
@@ -7,6 +7,7 @@ | |||
#include <variant> | |||
#include <vector> | |||
|
|||
#include <fmt/ranges.h> |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
we can probably remove this, since it's in Logger.h
now
#include <fmt/ranges.h> | |
#include <fmt/ranges.h> |
/// @action_function{scalar filter} checks if the particle passes fiducial cuts | ||
/// @param traj_row data struct of the particle in REC::Traj | ||
/// @param torus toroidal magnetic field sign | ||
/// @param pid pid of the particle | ||
/// @returns `true` if passes fiducial cuts | ||
bool Filter(FiducialFilter::traj_row_data const traj_row, int const torus, int const pid) const; |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
This isn't an action function, since traj_row
is not a simple scalar. Perhaps you need a vector action function here; I believe it would be the first (see #169). For this PR, I recommend:
- change the docstring so that it's not registering as an action function (remove
@action_function{scalar filter}
) - open an issue saying
FiducialCuts
lacks an action function
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
We need better documentation on what an action function is, exactly; added to #141
hipo::banklist::size_type b_config; | ||
|
||
/// Pi | ||
const double PI = 3.14159265; |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
const double PI = 3.14159265; | |
const double PI = M_PI; |
or replace PI
with M_PI
everywhere
|
||
/// @brief_algo Filter the `REC::Particle` bank by applying DC (drift chamber) fiducial cuts | ||
/// | ||
/// @begin_doc_algo{Filter} |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
new docstring syntax (#223)
/// @begin_doc_algo{Filter} | |
/// @begin_doc_algo{clas12::FiducialFilter | Filter} |
Added a Fiducial Cut algorithm that handles pid==11,211,-211,2212 drift chamber cuts using REC::Traj bank data
Currently only using pass1 parameterization
meson test validator-clas12-FiducialFilter --verbose --test-args '\-f /cache/clas12/rg-a/production/recon/fall2018/torus-1/pass1/v1/dst/train/nSidis/nSidis_005036.hipo \-n 0 \-o ../validator_output'
outputs before and after REC::Traj [x,y] 2d histograms for each drift chamber number. Below is the result for DC1Before Fiducial Cuts
After Fiducial Cuts