SunSpec 2

CI hacs GitHub release Quality Scale

Works with: KACO . SolarEdge . Fronius . SMA . Kostal . Sungrow . Delta . GoodWe . ABB / FIMER . Power-One . SunPower . Chint Power Systems and any other inverter, meter or battery that speaks the SunSpec Modbus specification. SunSpec is the manufacturer-independent standard for photovoltaic equipment communication; if your device documentation mentions "SunSpec Modbus" or you can find the SunSpec ID register holding 0x53756e53 ("SunS") at one of the standard base addresses, this integration will talk to it.

What this is

A Home Assistant integration for any device that implements the SunSpec Information Model over Modbus TCP. Built on pysunspec2 (the official SunSpec Alliance reference client) - hence the sunspec2 name. The integration auto-discovers which SunSpec model blocks the device exposes and turns each readable point into a Home Assistant sensor.

Use cases

  • Plug your inverter into the HA Energy dashboard with the lifetime energy register as the production source. No template sensors, no Modbus YAML, no per-brand integration needed.
  • Multi-brand homes: cover a SolarEdge string and a KACO Powador with the same integration, no setup difference.
  • Production monitoring with automations: build "battery charge from PV surplus" or "switch on the wallbox when production exceeds X kW" flows directly off the AC power sensor.
  • Diagnostic dashboards: temperatures, operating state, error events and DC-side currents/voltages are all exposed as separate sensors so a card with a glance at "what is the inverter doing right now" is one drag-and-drop away.

Features

  • Auto-discovery of SunSpec model blocks on the device, with model multi-select in the config flow so the user picks which families become sensors.
  • Active network scan ("Add Integration -> SunSpec -> Scan my network"): probes Modbus TCP port 502 across the local subnet, ARP-matches responders against a curated SunSpec vendor MAC OUI list, and floats inverter-vendor matches to the top of the picker.
  • Passive DHCP discovery as a best-effort second path: when HA sees a fresh DHCP lease whose MAC matches one of the supported vendor OUIs, the integration appears as a discovered tile in Devices & Services.
  • Auto-detected nameplate AC power: reads SunSpec model 120 (WRtg) or model 121 (WMax) on the first cycle and pre-fills the plausibility filter so the user does not have to type the inverter's rated power by hand.
  • Plausibility filter drops dawn / dusk garbage (the MW or TWh spikes some inverters report at startup) before they poison long-term statistics.
  • Resilience for flaky inverter networks: in-cycle retry after a short pause, plus stale-data tolerance that keeps sensors on their last good value through up to five consecutive failed cycles. A KACO Powador with a chronically twitchy ethernet link no longer flips to "unavailable" every other minute.
  • Friendly device names: the device shows up in HA as Powador 7.8 TL3 (or whatever the Md field of common model 1 reports) instead of a generic SunSpec block label.
  • Structured per-device logging with [host:port#unit_id] prefix on every line so multi-inverter setups stay triageable from a single log stream.
  • One-click diagnostics dump with the host redacted, plus optional raw-register capture so a bug report can be reproduced from the JSON file alone.
  • Repairs panel integration for persistent transport / protocol / device errors with actionable troubleshooting text in English and German.

Supported devices

Tested in production against a KACO Powador 7.8 TL3 (firmware V2.30). Designed to work with anything that implements the SunSpec Information Model over Modbus TCP, including:

  • KACO Powador, blueplanet
  • SolarEdge SE / HD-Wave / Energy Hub
  • Fronius Symo, Primo, Galvo
  • SMA Sunny Boy / Tripower (with the Speedwire Modbus profile enabled in Sunny Explorer)
  • Kostal Plenticore, Piko
  • Sungrow SG / SH series
  • GoodWe XS / DT / ET
  • ABB / FIMER / Power-One Aurora, Trio, UNO, REACT
  • SunPower SPR-8000m / SPR-10000m
  • Delta Solivia, RPI
  • Chint Power Systems CPS

Anything not in the list above that advertises "SunSpec Modbus TCP" in its documentation should also work; the integration is brand-agnostic by design.

Installation via HACS

  1. HACS -> three-dot menu -> Custom repositories
  2. URL: https://github.com/hilman2/ha-sunspec2, Type: Integration
  3. In HACS find SunSpec Modbus -> Download
  4. Restart Home Assistant
  5. Settings -> Devices & Services -> Add Integration -> SunSpec Modbus
  6. Pick the connection type:
    • Enter IP address manually for Modbus TCP if you know the IP
    • Scan my network for Modbus TCP if you don't know the IP
    • Connect via serial port for Modbus RTU over RS-485 (typically a USB-to-RS-485 adapter on /dev/ttyUSB0 or COM3)
  7. Confirm the connection details (port 502 + unit ID 1 for TCP, or serial port + baud rate + parity + unit ID for RTU)
  8. Pick the SunSpec models you want sensors for and optionally enter the inverter's nameplate AC power for the plausibility filter

If your inverter is on the same LAN as Home Assistant and uses one of the supported manufacturers, HA can also detect it via DHCP automatically and offer it as a discovered integration on the Devices & Services page - you only have to confirm.

Configuration parameters

Parameter Where Default Purpose
transport Setup tcp Modbus transport. Either tcp or rtu. RTU mode talks to the inverter over a serial line (RS-485) instead of Ethernet
host Setup TCP, Reconfigure - Inverter IP or hostname (TCP only)
port Setup TCP, Reconfigure 502 Modbus TCP port (TCP only)
serial_port Setup RTU - Serial device path, e.g. /dev/ttyUSB0 or COM3 (RTU only)
baudrate Setup RTU 9600 Serial baud rate (RTU only)
parity Setup RTU N Serial parity, N (none) or E (even). RTU only
unit_id Setup, Reconfigure 1 Modbus unit / slave ID
prefix Setup, Options empty Optional prefix for the device name (e.g. Garage, Cellar) for multi-inverter setups
scan_interval Setup, Options 30 s How often the coordinator polls the inverter
models_enabled Setup, Options sensible defaults Which SunSpec model blocks become sensors
max_ac_power_kw Setup, Options auto-detect from model 120/121 Plausibility filter ceiling. Drops readings above this value
capture_raw_registers Options off Wraps every Modbus read so the bytes appear in the diagnostics dump

How the integration polls

A single DataUpdateCoordinator per config entry runs the following loop, by default every 30 seconds:

  1. Acquire a class-level per-(host, port) asyncio.Lock. This matters when several config entries share the same Modbus TCP gateway: KACO Powador and many other devices only allow one Modbus TCP slot at a time, so two coordinators behind one gateway would race each other without this lock.
  2. Walk every enabled SunSpec model and read its valid points.
  3. On the first successful cycle: cache the inverter's full model list, the common-block device info, and the auto-detected nameplate.
  4. On a successful cycle: reset every per-category failure counter and clear any active Repairs issues. If the previous run had failed, log a single recovery WARNING so the user can correlate the recovery moment in the log.
  5. Close the TCP socket with SO_LINGER=0 so the kernel sends a TCP RST instead of a polite FIN. Single-slot inverters free their slot immediately on RST instead of waiting on their own keep-alive.

On failure, the coordinator does NOT immediately mark the entity unavailable. Instead:

  1. In-cycle retry: release the gateway lock, sleep 5 seconds, then run the cycle one more time. This catches the most common failure mode (a one-shot blip).
  2. Stale-data tolerance: while consecutive cycles keep failing, the entity available property serves the last good value for up to 5 cycles. Only after that does the sensor flip to "unavailable". With the default 30 s interval plus the 5 s retry, this rides out roughly three minutes of dropped connectivity without bouncing the long-term statistics graphs to "unknown".
  3. Repairs panel issues fire after 1 consecutive protocol error or 3 consecutive transport / device errors, with actionable text in English and German. Issues clear automatically on the next successful cycle.

Example uses

Energy dashboard

The lifetime energy sensor (WH on a three-phase inverter, key lifetime_energy) reports the inverter's total produced energy in Wh and has the total_increasing state class. Add it to Settings -> Dashboards -> Energy as a Solar production source. No template sensor needed.

Tip on units: SunSpec reports lifetime energy in raw watt-hours, which can produce huge numbers (e.g. 50,000,000 Wh after a couple of years). HA's Energy Dashboard handles that correctly internally, but if you prefer kWh in your dashboards you can change the displayed unit per sensor without losing history:

  1. Open the lifetime energy entity in Settings -> Devices & Services -> SunSpec Modbus -> ... -> Lifetime energy
  2. Click the cog icon in the top right
  3. Change Unit of Measurement from Wh to kWh
  4. HA asks whether to convert the existing long-term statistics - confirm and your historical graph stays consistent.

This is a per-entity HA UI feature, not something the integration configures - we expose the raw SunSpec values so the conversion choice stays with the user.

Surplus-driven wallbox automation

The AC power sensor (W, key watts) gives the current production in watts. A simple "switch on the wallbox if production exceeds 3 kW for 5 minutes" automation reads it directly:

trigger:
  - platform: numeric_state
    entity_id: sensor.powador_7_8_tl3_ac_power
    above: 3000
    for: "00:05:00"
action:
  - service: switch.turn_on
    target:
      entity_id: switch.wallbox

Quick-glance dashboard card

Drop the device for your inverter onto a dashboard via Add Card -> By device. The integration's friendly device name plus the per-entity translation_keys means the card already shows AC power, DC voltage, Frequency, Cabinet temperature and so on out of the box - no manual name: overrides.

Troubleshooting

The Diagnostics dump is the primary debugging tool. Get it via Settings -> Devices & Services -> SunSpec Modbus -> Download diagnostics. The host field is automatically redacted, the captured raw register bytes (when enabled) make most bugs reproducible from the JSON file alone, and the per-category recent-error buffer plus the consecutive-failure counters tell you immediately what went wrong.

Common situations and what to check:

  • All sensors unavailable after a model selection edit: you saved the options form with no models ticked. Re-open the options flow and re-tick the models you want. v0.7.6 onwards refuses to save an empty selection; if you are on an older version, update first.
  • All sensors unavailable and Repairs shows a cjne_conflict issue: the legacy cjne/ha-sunspec integration is still loaded for the same host. Single-slot inverters cannot be polled from two integrations at once. Uninstall cjne via HACS, restart Home Assistant, and the migration runs automatically.
  • Sensors flip to unavailable for a few minutes every few hours: this is exactly what the resilience features (in-cycle retry + stale tolerance) are designed to absorb. If you are still seeing this on v0.8.x or later, it usually means the underlying network link is dropping for longer than three minutes - check the WiFi / ethernet to the inverter.
  • Dawn / dusk spikes in your statistics: set the Peak AC power option to your inverter's nameplate. The plausibility filter drops every reading above that value, including the MW / TWh garbage some inverters generate at startup.
  • Repairs panel says "Cannot reach SunSpec inverter": open the diagnostics dump, look at recent_errors. If the same error appears three times in a row, the inverter is genuinely unreachable - check power, network and that no other Modbus client is holding the slot.

Experimental: inverter write controls (BETA, opt-in)

Important: this is genuinely risky. Read the whole section before ticking the opt-in. Writing to a Modbus register on a real inverter can persist a configuration change that locks you out of the device until a physical reset. There are no test users yet who have validated this code path against real hardware - the integration owner does not have an inverter that exposes SunSpec model 123.

v0.12.0 adds an opt-in beta for setpoint control via the standard SunSpec model 123 (Immediate Controls). When enabled, the integration registers two extra HA platforms (number and switch) plus a service action so you can curtail your inverter's export from HA automations.

What you get when you enable it

Entity Type SunSpec point What it does
Export limit Number (0..100 %) model 123 WMaxLimPct Caps AC output to N % of nameplate. Set to 0 for zero-export operation
Power factor setpoint Number (-1..1) model 123 OutPFSet Cos-phi setpoint for reactive power control
Export limit enabled Switch model 123 WMaxLim_Ena The export limit only takes effect while this switch is ON
Power factor enabled Switch model 123 OutPFSet_Ena The PF setpoint only takes effect while this switch is ON
Inverter grid connection Switch model 123 Conn Most dangerous: turning OFF disconnects the inverter from the grid entirely

Plus the sunspec2.set_export_limit service action with two parameters (config_entry_id, percent, optional enable) so automations can flip the export limit without going through a Number entity.

Why it's opt-in

  • Vendor deviations: SunSpec model 123 is part of the standard but vendors are inconsistent about which firmware revisions expose it, what scale-factor handling they apply, and what ranges they accept. We test against the spec, not against your specific firmware.
  • Persistence semantics vary: some inverters persist a write through power-cycle, others reset to defaults on reboot. Some require a non-zero WMaxLimPct_RvrtTms (revert timeout) to prevent the limit from sticking forever.
  • No real-hardware test on the integration owner's side: my KACO Powador 7.8 TL3 does not expose model 123, so I cannot smoke-test the write path against a live device. The first community user who runs this on a real inverter is doing the validation work, hence the BETA flag.

How to enable

  1. Open Settings → Devices & Services → SunSpec Modbus → Configure
  2. Click through to the model options step
  3. Tick "Enable experimental write controls (BETA)"
  4. Save - the integration reloads and the Number / Switch entities appear under your inverter's device card

If your inverter does NOT expose model 123, the entities will not register even with the flag on - the diagnostics dump's scanned_models array tells you whether 123 is present.

Looking for testers

If you are running this beta on a real inverter and want to share results, please open an issue on https://github.com/hilman2/ha-sunspec2/issues with the model name, the firmware revision, and a description of which writes worked and which did not. That feedback is what will let us drop the BETA flag and ship v1.0.

Multiple inverters behind one gateway

If you have several SunSpec devices sharing one connection - for example two Modbus TCP slaves behind a single network gateway, or several RS-485 slaves on the same /dev/ttyUSB0 bus - just add one config entry per unit ID with the same host/port (TCP) or serial port/baud rate (RTU).

The integration uses a per-(host, port) asyncio.Lock that all coordinators behind the same connection share. Reads are serialised across all matching config entries, so:

  • on Modbus TCP gateways that only allow one TCP slot at a time (notably the SolarEdge SE-CC, several KACO models), the lock guarantees you never see two concurrent connects fighting for the slot
  • on RS-485 buses the same lock covers /dev/ttyUSB0 so two coordinators never open the serial port concurrently (each coordinator runs an open() -> scan -> read -> close() cycle fully within the lock)

Each unit ID lands as its own HA device, with its own friendly name from the inverter's Md field, its own sensors, its own options. The only thing they share is the bus.

You don't have to enable any setting for this. The behaviour is automatic the moment you add a second config entry whose host/port (TCP) or serial port/baud rate (RTU) matches an existing one.

Known limitations

  • Single Modbus TCP slot devices like KACO Powador can only be polled from one OS process at a time. ha-sunspec2 itself handles the multi-coordinator case correctly via its per-gateway lock (see "Multiple inverters behind one gateway" above), but you cannot run ha-sunspec2 in parallel with cjne, openHAB, or any other Modbus client against the same device. The integration detects an active cjne entry on the same host and refuses to start with a clear Repairs panel message.
  • DHCP discovery requires a fresh lease, which means it does not fire for inverters with a static IP (most home installs) and only fires every few hours for DHCP leases. The active Scan my network path is the workaround for both situations.
  • Vendor-specific SunSpec extension models (the 6xx, 7xx, 8xx blocks) are read if the inverter exposes them, but the per-point translations are limited to the standard inverter / nameplate / settings keys. Vendor-specific events fall back to the SunSpec spec label from pysunspec2.
  • Auto-detected nameplate only works for inverters that expose model 120 (WRtg) or model 121 (WMax). Older or vendor-stripped firmware (notably some KACO Powador models) does not have these blocks; the user has to type the nameplate by hand once during setup.

Migration from cjne/ha-sunspec

If you previously used the cjne/ha-sunspec integration and your Home Assistant already has sensor entities under the sunspec platform (e.g. sensor.inverter_three_phase_watts), SunSpec 2 is the natural upgrade path. Your entity IDs, Recorder history, dashboards, and automations are preserved - the migration automatically retargets the existing entities to the new platform on first setup.

The cjne integration is the original community port and laid the groundwork for everything that followed. SunSpec 2 builds on that work, adds the resilience features (in-cycle retry, stale-data tolerance), the active network scan, the friendly device names, and the full Bronze + Silver + Gold quality scale items. Big thanks to @cjne for the original codebase and the years of community support.

Migration steps:

  1. In HACS, uninstall cjne/ha-sunspec
  2. Restart Home Assistant
  3. Install SunSpec Modbus as described in Installation via HACS
  4. Add the SunSpec Modbus integration with the same host, port and unit ID you used before
  5. A notification confirms: "X sensor(s) were migrated from sunspec to sunspec2. Their entity IDs and Recorder history have been preserved."

That's it. The Energy dashboard, automations and historical graphs keep working without any further action.

If both integrations are loaded at the same time, SunSpec 2 detects the conflict and refuses to start with a clear Repairs panel message until cjne is uninstalled. Single-slot inverters cannot be polled from two integrations simultaneously.

Removing the integration

  1. Settings -> Devices & Services -> SunSpec Modbus -> three-dot menu -> Delete for each configured device. This removes the entry, all sensor entities, and their device entry from the registry.
  2. (Optional) In HACS, three-dot menu on SunSpec Modbus -> Remove. This deletes the custom_components/sunspec2 directory from your config.
  3. Restart Home Assistant so HA forgets the integration was ever loaded.

Removing the integration leaves the inverter itself untouched. It just stops talking to it. Recorder history for the deleted entities is kept by HA's Recorder until its own purge interval kicks in (10 days by default), so dashboards that reference the entities will go to "unknown" but not lose old data immediately.

Quality scale

This integration meets the Home Assistant Gold quality scale. Every Bronze, Silver and Gold rule is documented in custom_components/sunspec2/quality_scale.yaml with one entry per rule, marked done / exempt with a one-paragraph explanation of how the rule is satisfied.

The current state at a glance:

  • Bronze: 18/18 done or exempt - config flow, runtime data, test before configure / before setup, device-info, has-entity-name, unique config entry, removal docs, etc.
  • Silver: 9/9 done or exempt - entity-unavailable with stale-data tolerance, log-when-unavailable, parallel-updates, test coverage with 120+ tests, etc.
  • Gold: 18/18 done or exempt - active discovery, reconfiguration flow, stale-devices, entity-translations, exception-translations, icon-translations, entity-category, entity-disabled-by-default, all the docs-* items, etc.

Reporting issues

Bug reports are welcome at https://github.com/hilman2/ha-sunspec2/issues. Always include the diagnostics download (Settings -> Devices & Services -> SunSpec Modbus -> Download diagnostics). The host is automatically redacted, and the captured raw register bytes (when enabled) make most bugs reproducible from the JSON alone.

License

MIT. See LICENSE.