Notifications
You must be signed in to change notification settings - Fork 154
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
Address output of branch losses mentioned in #234.
- Add shunt loss columns (`psh_fr`, `qsh_fr`, `psh_to`, `qsh_to`) to branch data model. - Separate branch loss summary into series and shunt losses. - Add series loss columns to branch detail output. Thanks to Wilson González Vanegas. Ref: #234
- Loading branch information
Showing
20 changed files
with
577 additions
and
380 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
|
@@ -35,6 +35,10 @@ | |
% ``ql_fr`` *double* reactive power injection at "from" end | ||
% ``pl_to`` *double* active power injection at "to" end | ||
% ``ql_to`` *double* reactive power injection at "to" end | ||
% ``psh_fr`` *double* active power shunt losses at "from" end | ||
% ``qsh_fr`` *double* reactive power shunt losses at "from" end | ||
% ``psh_to`` *double* active power shunt losses at "to" end | ||
% ``qsh_to`` *double* reactive power shunt losses at "to" end | ||
% =========== ========= ======================================== | ||
|
||
% MATPOWER | ||
|
@@ -57,6 +61,7 @@ | |
tm % transformer off-nominal turns ratio for branches that are on | ||
ta % xformer phase-shift angle (radians) for branches that are on | ||
rate_a % long term flow limit (p.u.) for branches that are on | ||
loss_tol = 1e-4; % loss values < this are displayed as ``-`` | ||
end %% properties | ||
|
||
methods | ||
|
@@ -92,12 +97,14 @@ | |
'g_to', 'b_to', 'sm_ub_a', 'sm_ub_b', 'sm_ub_c', ... | ||
'cm_ub_a', 'cm_ub_b', 'cm_ub_c', 'vad_lb', 'vad_ub', ... | ||
'tm', 'ta', ... %% remove these when we separate out xformers | ||
'pl_fr', 'ql_fr', 'pl_to', 'ql_to'} ); | ||
'pl_fr', 'ql_fr', 'pl_to', 'ql_to', ... | ||
'psh_fr', 'qsh_fr', 'psh_to', 'qsh_to'} ); | ||
end | ||
|
||
function vars = export_vars(obj) | ||
% | ||
vars = {'pl_fr', 'ql_fr', 'pl_to', 'ql_to'}; | ||
vars = {'pl_fr', 'ql_fr', 'pl_to', 'ql_to', ... | ||
'psh_fr', 'qsh_fr', 'psh_to', 'qsh_to'}; | ||
end | ||
|
||
function s = export_vars_offline_val(obj) | ||
|
@@ -108,6 +115,10 @@ | |
s.ql_fr = 0; | ||
s.pl_to = 0; | ||
s.ql_to = 0; | ||
s.psh_fr = 0; | ||
s.qsh_fr = 0; | ||
s.psh_to = 0; | ||
s.qsh_to = 0; | ||
end | ||
|
||
function obj = initialize(obj, dm) | ||
|
@@ -193,11 +204,43 @@ | |
[email protected]_element(obj, dm, rows, out_e, mpopt, fd, pp_args); | ||
|
||
%% print branch summary | ||
fprintf(fd, ' %-29s %12.2f MW', 'Total branch losses', ... | ||
sum(obj.tab.pl_fr(obj.on)) + sum(obj.tab.pl_to(obj.on)) ); | ||
p_loss = sum(obj.tab.pl_fr(obj.on)) + sum(obj.tab.pl_to(obj.on)); | ||
p_shunt = sum(obj.tab.psh_fr(obj.on)) + sum(obj.tab.psh_to(obj.on)); | ||
p_series = p_loss - p_shunt; | ||
if abs(p_series) < obj.loss_tol | ||
p_series_str = '- '; | ||
else | ||
p_series_str = sprintf('%12.2f', p_series); | ||
end | ||
fprintf(fd, ' %-29s %12s MW', 'Total branch series losses', ... | ||
p_series_str); | ||
if mpopt.model(1) ~= 'D' %% AC model | ||
q_loss = sum(obj.tab.ql_fr(obj.on)) + sum(obj.tab.ql_to(obj.on)); | ||
q_shunt = sum(obj.tab.qsh_fr(obj.on)) + ... | ||
sum(obj.tab.qsh_to(obj.on)); | ||
q_series = q_loss - q_shunt; | ||
if abs(q_series) < obj.loss_tol | ||
q_series_str = '- '; | ||
else | ||
q_series_str = sprintf('%12.2f', q_series); | ||
end | ||
fprintf(fd, ' %12s MVAr', q_series_str); | ||
end | ||
fprintf(fd, '\n'); | ||
if abs(p_shunt) < obj.loss_tol | ||
p_shunt_str = '- '; | ||
else | ||
p_shunt_str = sprintf('%12.2f', p_shunt); | ||
end | ||
fprintf(fd, ' %-29s %12s MW', 'Total branch shunt losses', ... | ||
p_shunt_str ); | ||
if mpopt.model(1) ~= 'D' %% AC model | ||
fprintf(fd, ' %12.2f MVAr', ... | ||
sum(obj.tab.ql_fr(obj.on)) + sum(obj.tab.ql_to(obj.on)) ); | ||
if abs(q_shunt) < obj.loss_tol | ||
q_shunt_str = '- '; | ||
else | ||
q_shunt_str = sprintf('%12.2f', q_shunt); | ||
end | ||
fprintf(fd, ' %12s MVAr', q_shunt_str ); | ||
end | ||
fprintf(fd, '\n'); | ||
end | ||
|
@@ -209,6 +252,33 @@ | |
' ID Bus ID Bus ID Status P (MW) Q (MVAr) P (MW) Q (MVAr)', ... | ||
'-------- -------- -------- ------ -------- -------- -------- --------' } ]; | ||
%% 1234567 123456789 123456789 -----1 1234567.90 123456.89 123456.89 123456.89 | ||
if mpopt.model(1) ~= 'D' %% AC model | ||
h{end-2} = [h{end-2} ' Series Loss']; | ||
h{end-1} = [h{end-1} ' P (MW) Q (MVAr)']; | ||
h{end} = [h{end} ' -------- --------']; | ||
%% 12345.789 123456.89 | ||
%% 12345.789 123456.89 | ||
end | ||
end | ||
|
||
function f = pp_get_footers_det(obj, dm, out_e, mpopt, pp_args) | ||
% | ||
if mpopt.model(1) == 'D' %% DC model (series losses) | ||
f = {}; | ||
else %% AC model | ||
p_loss = sum(obj.tab.pl_fr(obj.on)) + ... | ||
sum(obj.tab.pl_to(obj.on)); | ||
p_shunt = sum(obj.tab.psh_fr(obj.on)) + ... | ||
sum(obj.tab.psh_to(obj.on)); | ||
p_series = p_loss - p_shunt; | ||
q_loss = sum(obj.tab.ql_fr(obj.on)) + ... | ||
sum(obj.tab.ql_to(obj.on)); | ||
q_shunt = sum(obj.tab.qsh_fr(obj.on)) + ... | ||
sum(obj.tab.qsh_to(obj.on)); | ||
q_series = q_loss - q_shunt; | ||
f = {' -------- --------', | ||
sprintf('%69s Total:%9.3f %9.2f', '', p_series, q_series)}; | ||
end | ||
end | ||
|
||
function TorF = pp_have_section_det(obj, mpopt, pp_args) | ||
|
@@ -223,6 +293,13 @@ | |
obj.tab.status(k), ... | ||
obj.tab.pl_fr(k), obj.tab.ql_fr(k), ... | ||
obj.tab.pl_to(k), obj.tab.ql_to(k) ); | ||
if mpopt.model(1) ~= 'D' %% AC model | ||
str = sprintf('%s %9.3f %9.2f', str, ... | ||
obj.tab.pl_fr(k) + obj.tab.pl_to(k) ... | ||
- obj.tab.psh_fr(k) - obj.tab.psh_to(k), ... | ||
obj.tab.ql_fr(k) + obj.tab.ql_to(k) ... | ||
- obj.tab.qsh_fr(k) - obj.tab.qsh_to(k) ); | ||
end | ||
end | ||
end %% methods | ||
end %% classdef |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Oops, something went wrong.