175 changes: 175 additions & 0 deletions .agents/skills/mz-debug-replica-latency/SKILL.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,175 @@
---
name: mz-debug-replica-latency
description: >
Triage a production Materialize replica that is stalling or running slow,
using Grafana (Prometheus) and PolarSignals. Trigger: a "persist ... heartbeat
call took Ns" or slow-consensus warning, "why is this replica slow", "persist
op taking seconds", "consensus/CRDB looks slow", "environmentd/clusterd
stalled", "reads timing out in prod", or a pasted prod log line plus Grafana
access. Reach for this whenever a single replica or environment shows
multi-second internal latency in production and you need to decide whether the
cause is the backing store, the process/runtime, shard contention, or memory
pressure, even if the user only pastes a log line and asks "what is this".
---

# Debugging production replica latency

A single warning like `mz_persist_client::read reader (...) of shard (...)
heartbeat call took 60.6s` almost never means what it says on the surface.
The warning names a downstream symptom (a slow consensus/persist operation),
but the real cause is usually one layer down: the backing store, the process
runtime, shard contention, or local memory pressure.
This skill is the triage procedure to tell those apart with evidence, instead
of guessing from the log line.

The core mental model: most of these "slow op" warnings time an `.await` on an
external call. That call can be slow because the store is genuinely slow, OR
because the local process is not polling the future (it is stalled off-CPU on
paging, blocked threads, or CPU starvation). The whole job here is to figure out
which, because the fixes are completely different.

## What you need

* Grafana MCP (Prometheus) access to the production metrics datasources.
* PolarSignals MCP access for CPU profiles (optional but useful).
* The identifying labels for the affected workload: namespace (the environment),
and pod (the specific replica or environmentd). A log line usually does not
carry these, so the user must supply them or you infer them from context.

Do not hardcode datasource UIDs or environment identifiers. Discover them at
runtime, as below. Treat metric names as the stable contract, since UIDs and
label values drift.

## Step 0: Locate the environment

List Prometheus datasources (`list_datasources type=prometheus`). Production
regions follow a `cloud-production <region>` naming pattern, with separate
datasources per region. You do not know the region up front, so probe.

Confirm the environment lives in a datasource before querying deeply. A cheap
existence check:

```promql
count by (namespace) (mz_persist_external_started_count{namespace="<env-namespace>"})
```

Run it across the production datasources until one returns data. That datasource
is your environment's region. The infra metrics (`kube_*`, `container_*`,
cadvisor) live in the same datasource as the `mz_*` app metrics.

NOTE: the pod label is `pod`. If a `pod=` filter returns empty but the namespace
has data, you probably have the wrong metric name, not the wrong label. Verify
the exact metric name with `list_prometheus_metric_names` before assuming the
label is wrong. Persist external-op metrics are `mz_persist_external_seconds`,
`mz_persist_external_started_count`, `mz_persist_external_succeeded_count` (note:
no `op` in the metric name; `op` is a label).

## The decision tree

Work top to bottom. Each step narrows the cause and tells you what to read next.

1. **Is the slowness one replica, or the whole environment?**
Compare the suspect pod's external-op latency against its siblings on the
same backing store. Average op latency:

```promql
sum(rate(mz_persist_external_seconds{op="consensus_cas", namespace="<ns>"}[2m]))
by (pod)
/ sum(rate(mz_persist_external_started_count{op="consensus_cas", namespace="<ns>"}[2m]))
by (pod)
```

Or `topk(10, ...)` of the same. If every pod is elevated, suspect the backing
store (CRDB) or a shared dependency. If only one pod is elevated while others
sit at single-digit milliseconds, the store is healthy and the problem is
local to that replica. This single comparison eliminates half the hypotheses.

2. **If isolated to one pod: are reads slow too, or only writes?**
Check a trivial read op:

```promql
rate(mz_persist_external_seconds{op="consensus_head", pod="<pod>"}[2m])
/ rate(mz_persist_external_started_count{op="consensus_head", pod="<pod>"}[2m])
```

`consensus_head` is a point read. If it averages multiple seconds, the store
cannot be the cause, because the same store serves other pods in microseconds.
Multi-second point reads mean the process is not polling its futures, i.e. the
runtime itself is stalled. Go to the memory-pressure and CPU-starvation
checks. If reads are fast but only writes (`consensus_cas`) are slow, suspect
shard contention (next step).

3. **Is it shard contention (lost compare-and-set races)?**
A persist command that loses the CaS re-fetches state and retries with no
timeout, so heavy contention inflates wall-clock.

```promql
increase(mz_persist_cmd_cas_mismatch_count{pod="<pod>"}[4m])
```

This metric carries a `cmd` label, so you see which command is contending
(e.g. `downgrade_since`, `compare_and_append`). A large mismatch count on the
command named in the warning confirms a retry loop. Contention alone rarely
produces 60s stalls on its own. It usually compounds with a runtime stall:
each retry has to touch state that is slow to access.

4. **Is the process stalled by memory pressure / swap?**
See `references/memory-pressure.md`. This is the most common root cause of an
isolated replica whose reads AND writes are all slow.

5. **Is the process CPU-starved or throttled?**
See `references/cpu-and-runtime.md`.

## Confirming off-CPU stalls with profiles

When you suspect a runtime stall, a CPU profile is the tie-breaker. In
PolarSignals, list projects and pick the cloud project, then pull an on-CPU
flame graph or table for the pod and time window.

The key inference: the production cloud project typically exposes ONLY an on-CPU
profile (`parca_agent:samples:count:cpu:nanoseconds:delta`), not an off-CPU /
wallclock profile. So you cannot directly profile a blocked thread. Instead, use
on-CPU as a process of elimination: if the relevant subsystem (e.g. persist) is
near-idle on-CPU during a window where its ops were taking seconds, the time was
spent OFF-CPU (blocked on IO, locks, or page faults), not computing. A near-idle
on-CPU profile during a stall is itself the evidence of a blocking, not
compute-bound, problem.

Flame graphs for Rust binaries are huge. Filter the table by `filename` (e.g.
the crate name) and start with a tight `time_range` to avoid oversized results.

## A telling corroboration: scrape blackouts

When a process stalls hard (paging, blocked runtime), it stops serving its own
`/metrics` endpoint, and often the node's cadvisor loses the container too. In
the raw counter series you will see a gap: timestamps jump across the stall
window with no samples in between. If both the app `/metrics` series and the
node cadvisor series blank out over the same window, that is strong independent
evidence the whole process stalled, not that one dependency was slow. Always
look at raw counter series (not just `rate()`) around the incident, because
`rate()` over a gap can silently return empty or interpolate.

## Metric cheat-sheet

* `mz_persist_external_seconds{op,pod}` / `mz_persist_external_started_count{op,pod}`
— average external-op latency. Ops include `consensus_cas`, `consensus_head`,
`consensus_scan`, `consensus_truncate`, `blob_get`, `blob_set`, etc.
* `mz_persist_cmd_cas_mismatch_count{cmd,pod}` — CaS retry / contention per command.
* `mz_persist_cmd_seconds{cmd,pod}` — per-command time, to see which command dominates.
* `mz_metrics_libc_ru_majflt_total{pod}` — major page faults (swap-ins). See memory reference.
* `container_memory_rss`, `container_memory_swap`, `container_memory_working_set_bytes`
— memory footprint. See memory reference.
* `kube_pod_container_resource_limits{resource="memory"}` — the cgroup limit
(dedupe duplicate kube-state-metrics series with `max()`).
* `container_cpu_cfs_throttled_seconds_total`, `mz_metrics_libc_ru_nivcsw_total`
— CPU throttling / involuntary preemption. See CPU reference.

## Writing it up

These investigations usually end in a ticket to the team that owns the
subsystem. Lead with the conclusion (root cause), then the evidence chain in the
order that eliminates alternatives: scope (one pod vs fleet), then the
store-is-healthy proof (sibling latencies, fast point reads elsewhere), then the
local cause (memory/CPU), then how it ties back to the original warning. State
plainly that the warning was a symptom, not the cause, so the next responder
does not chase the wrong layer.
Original file line number Diff line number Diff line change
@@ -0,0 +1,61 @@
# CPU starvation and runtime stalls

A replica can stall even with healthy memory if its threads cannot get CPU, or
if the async runtime is blocked. The symptom overlaps with memory pressure
(every `.await` looks slow), so use these checks to distinguish.

## CPU throttling (cgroup CPU quota)

If the container hits its CPU limit, the kernel throttles it: runnable threads
are forcibly descheduled until the next quota period. Heavy throttling stalls
everything, including the futures running persist ops.

```promql
rate(container_cpu_cfs_throttled_seconds_total{pod="<pod>"}[1m])
rate(container_cpu_cfs_throttled_periods_total{pod="<pod>"}[1m])
/ rate(container_cpu_cfs_periods_total{pod="<pod>"}[1m])
```

The second expression is the fraction of scheduling periods that were throttled.
Sustained high values mean the container is CPU-starved by its own quota.

Involuntary context switches corroborate CPU contention at the process level:

```promql
rate(mz_metrics_libc_ru_nivcsw_total{pod="<pod>"}[1m])
```

A spike in involuntary switches means the scheduler is preempting the process
against its will, i.e. it wants CPU it cannot get. Voluntary switches
(`ru_nvcsw_total`) are the opposite, the process yielding (often blocking on
IO), which points back toward the memory/IO story.

## Async runtime blocked by synchronous work

A subtler cause: a blocking operation on a Tokio worker thread (a blocking
syscall, a long synchronous compute section, a contended std mutex held across
work) starves the runtime. Other tasks on that worker, including persist
heartbeats and consensus client futures, cannot make progress until it returns.

Signals:

* On-CPU profile shows a single subsystem dominating CPU for the whole window
(real compute), while the stalled subsystem is absent. This differs from the
memory-pressure case, where the on-CPU profile is near-idle overall because
threads are off-CPU on page faults.
* No CPU throttling and no major-fault spike, yet ops are slow: look for a
blocking section in the hot path on-CPU.

## Distinguishing the three runtime-stall causes

* Memory/swap: on-CPU near-idle, `ru_majflt` spiking, mem+swap over limit.
* CPU throttle: `cfs_throttled` high, `ru_nivcsw` spiking, on-CPU may be busy.
* Blocking work on runtime: on-CPU shows one subsystem burning CPU, no throttle,
no fault spike.

## Fixes to recommend

* Throttling: raise the CPU limit, or reduce concurrent work on the replica.
* Blocking-on-runtime: move the offending work to a blocking thread pool
(`spawn_blocking`), shorten the synchronous section, or remove the lock held
across the await. Identify the exact frame from the on-CPU profile first.
Original file line number Diff line number Diff line change
@@ -0,0 +1,72 @@
# Memory pressure and swap thrashing

This is the most common root cause of a single replica whose persist reads and
writes are all slow while sibling replicas on the same backing store are fine.
The mechanism: the process working set exceeds physical RAM, the kernel pages
cold memory out to swap, and every later access to a swapped-out page is a major
page fault, a synchronous disk read that blocks the faulting thread. Under heavy
thrashing the runtime spends most of its wall-clock blocked on page-ins, so
every `.await` on an external call appears slow even though the store responded
instantly.

Production replicas may run on swap-enabled nodes (a dedicated nodepool, local
NVMe used as swap). Swap is meant as a soft cushion for transient spikes, not as
a place to hold a multiple of RAM resident. Sustained heavy swap is the incident.

## The decisive signal: major page faults

```promql
rate(mz_metrics_libc_ru_majflt_total{pod="<pod>"}[1m])
```

This is the process's own getrusage major-fault counter. Sustained rates on the
order of tens to hundreds of thousands per second mean the process is thrashing:
threads are continuously blocking on swap-in. Correlate the rate against the
incident window. It typically peaks during the stall and decays afterward,
matching when the slow operation finally completed.

NOTE: this metric is served on the same `/metrics` endpoint that blanks out
during a hard stall, so `rate()` over the exact gap can return empty. Query the
raw counter (`mz_metrics_libc_ru_majflt_total{pod="<pod>"}` as a range) and
compute deltas across the surrounding samples by hand. The jump across the gap
is what you want.

Sibling rusage metrics that corroborate: `mz_metrics_libc_ru_minflt_total`
(minor faults), `mz_metrics_libc_ru_nivcsw_total` (involuntary context switches,
also a CPU-pressure signal), `mz_metrics_libc_ru_maxrss_bytes`.

## Quantify the footprint

```promql
container_memory_rss{pod="<pod>", container="<container>"}
container_memory_swap{pod="<pod>", container="<container>"}
max(kube_pod_container_resource_limits{pod="<pod>", resource="memory"})
```

* `container_memory_rss` near the cgroup memory limit means the container is
pinned at its RAM ceiling.
* `container_memory_swap` is the cgroup memory+swap total. When it greatly
exceeds the RAM limit (and physical node RAM), the difference is resident in
swap. Hundreds of GB in swap is unambiguous thrashing.
* Use `max()` on the limit metric. kube-state-metrics often exposes duplicate
series (multiple scrape endpoints), which makes a bare `/` join fail with a
many-to-many error.

## What it looks like together

* One replica's external ops all in seconds, including trivial point reads.
* Sibling replicas on the same store at milliseconds.
* `ru_majflt` rate spiking into the tens or hundreds of thousands per second.
* mem+swap far above the RAM limit.
* App `/metrics` and node cadvisor scrapes blanking out over the stall window.
* On-CPU profile near-idle for the stalled subsystem (time spent off-CPU).

## Fixes to recommend

* Relieve memory: size the replica up, or reduce the dataflow working set, so it
fits in RAM with swap as headroom rather than primary storage.
* Alert on `rate(mz_metrics_libc_ru_majflt_total)` and `container_memory_swap`
for swap-enabled replicas. A single downstream warning understates how long
the replica was actually thrashing.
* Frame the original "slow op" warning as a symptom so responders fix memory,
not the persist/consensus layer.
Loading