Merge pull request #1834 from NREL/lixi_docs
Browse files Browse the repository at this point in the history
Clarify dehumidifier and pool/spa docs
  • Loading branch information
shorowit authored Sep 17, 2024
2 parents 7522094 + 963f14b commit 640cc10
Showing 1 changed file with 8 additions and 1 deletion.
9 changes: 8 additions & 1 deletion docs/source/workflow_inputs.rst
Original file line number Diff line number Diff line change
Expand Up @@ -4643,8 +4643,9 @@ If not entered, the simulation will not include a dehumidifier.
.. note::

Dehumidifiers are currently modeled as located within conditioned space; the model is not suited for a dehumidifier in, e.g., a wet unconditioned basement or crawlspace.
Dehumidifiers are currently modeled as located within conditioned space; the model is not suited for a dehumidifier in, e.g., a wet basement or crawlspace where there is significant moisture from the ground.
Therefore the dehumidifier Location is currently restricted to "conditioned space".
Like an HVAC system, the dehumidifier operates as needed to maintain the RH setpoint for the conditioned space.

HPXML Cooking Range/Oven
************************
Expand Down Expand Up @@ -4835,6 +4836,7 @@ If not entered, the simulation will not include a pool.

.. [#] Type choices are "in ground", "on ground", "above ground", "other", "unknown", or "none".
If "none" is entered, the simulation will not include a pool.
Any other value entered will indicate the presence of a pool; the specific value chosen does not affect the energy model.
Pool Pump
~~~~~~~~~
Expand All @@ -4856,6 +4858,7 @@ If not entered, the simulation will not include a pool pump.

.. [#] Type choices are "single speed", "multi speed", "variable speed", "variable flow", "other", "unknown", or "none".
If "none" is entered, the simulation will not include a pool pump.
Any other value entered will indicate the presence of a pool pump; the specific value chosen does not affect the energy model.
.. [#] If Value not provided, defaults based on the `2010 BAHSP <https://www1.eere.energy.gov/buildings/publications/pdfs/building_america/house_simulation.pdf>`_: 158.5 / 0.070 * (0.5 + 0.25 * NumberofBedrooms / 3 + 0.25 * ConditionedFloorArea / 1920).
If NumberofResidents provided, this value will be adjusted using the equations from RECS in :ref:`building_occupancy`.
.. [#] If WeekdayScheduleFractions or WeekendScheduleFractions not provided (and :ref:`schedules_detailed` not used), then :ref:`schedules_default` are used.
Expand All @@ -4881,6 +4884,7 @@ If not entered, the simulation will not include a pool heater.

.. [#] Type choices are "none, "gas fired", "electric resistance", or "heat pump".
If "none" is entered, the simulation will not include a pool heater.
Any other value entered will indicate the presence of a pool heater; the specific value chosen affects only the default kWh/year and therm/year values as described below.
.. [#] If Value not provided, defaults as follows:
\- **gas fired [therm/year]**: 3.0 / 0.014 * (0.5 + 0.25 * NumberofBedrooms / 3 + 0.25 * ConditionedFloorArea / 1920) (based on the `2010 BAHSP <https://www1.eere.energy.gov/buildings/publications/pdfs/building_america/house_simulation.pdf>`_)
Expand Down Expand Up @@ -4909,6 +4913,7 @@ If not entered, the simulation will not include a permanent spa.

.. [#] Type choices are "in ground", "on ground", "above ground", "other", "unknown", or "none".
If "none" is entered, the simulation will not include a permanent spa.
Any other value entered will indicate the presence of a permanent spa; the specific value chosen does not affect the energy model.
Permanent Spa Pump
~~~~~~~~~~~~~~~~~~
Expand All @@ -4930,6 +4935,7 @@ If not entered, the simulation will not include a permanent spa pump.

.. [#] Type choices are "single speed", "multi speed", "variable speed", "variable flow", "other", "unknown", or "none".
If "none" is entered, the simulation will not include a permanent spa pump.
Any other value entered will indicate the presence of a permanent spa pump; the specific value chosen does not affect the energy model.
.. [#] If Value not provided, defaults based on the `2010 BAHSP <https://www1.eere.energy.gov/buildings/publications/pdfs/building_america/house_simulation.pdf>`_: 59.5 / 0.059 * (0.5 + 0.25 * NumberofBedrooms / 3 + 0.25 * ConditionedFloorArea / 1920).
If NumberofResidents provided, this value will be adjusted using the equations from RECS in :ref:`building_occupancy`.
.. [#] If WeekdayScheduleFractions or WeekendScheduleFractions not provided (and :ref:`schedules_detailed` not used), then :ref:`schedules_default` are used.
Expand All @@ -4955,6 +4961,7 @@ If not entered, the simulation will not include a permanent spa heater.

.. [#] Type choices are "none, "gas fired", "electric resistance", or "heat pump".
If "none" is entered, the simulation will not include a permanent spa heater.
Any other value entered will indicate the presence of a permanent spa heater; the specific value chosen affects only the default kWh/year and therm/year values as described below.
.. [#] If Value not provided, defaults as follows:
\- **gas fired [therm/year]**: 0.87 / 0.011 * (0.5 + 0.25 * NumberofBedrooms / 3 + 0.25 * ConditionedFloorArea / 1920) (based on the `2010 BAHSP <https://www1.eere.energy.gov/buildings/publications/pdfs/building_america/house_simulation.pdf>`_)