Skip to content

PV sizing macro power limiting losses issue #2102

Description

@cpaulgilman

Describe the bug

The inverter power limiting loss values reported in the HTML report for the PV System Sizing macro seem too high.

For example, for the default Detailed PV / Single Owner configuration, the total kWh/year lost is 43,732,754 kWh in the macro results compared to 505228 kWh in SAM:

Image

This is because the macro is reporting the total over the lifetime instead of an annual value.

Solution is to modify the macro to report annual values instead of lifetime values.

Issue discovered when responding to https://sam.nrel.gov/forum/forum-general/5049-tips-for-system-sizing.html