Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

add outdoorTemperature to heatpump status reports #220

Open
wants to merge 1 commit into
base: master
Choose a base branch
from

Conversation

sumnerboy12
Copy link

based on documented room/remote temp from here and tested on my Mitsubishi AP50 high wall unit.

@sumnerboy12
Copy link
Author

Hmm - after running it for a few hours I just checked and the unit is now reporting 0x01 for the outdoor temp;

fc 62 01 30 10 03 00 00 0a 00 01 a9 a9 fe 42 00 02 60 82 00 00 d9

Which is reported as -63.5... 😟

@sumnerboy12
Copy link
Author

Ah of course, it only reports a valid outdoor temp if the unit is powered up and running. Not sure if you want to have this given it is not a constant stream of sensor data. Feel free to close the PR if you wish.