Skip to content

Commit

Permalink
Cited images properly and added link to site in index
Browse files Browse the repository at this point in the history
  • Loading branch information
Armando Pabon committed Aug 8, 2024
1 parent c0b99cc commit d18f3cb
Show file tree
Hide file tree
Showing 2 changed files with 10 additions and 24 deletions.
33 changes: 9 additions & 24 deletions doc/content/demonstration/electrothermal_contact_validation.md
Original file line number Diff line number Diff line change
Expand Up @@ -11,17 +11,17 @@ The sample cases are summarized below:
!media media/cincotti_validation_images/sample_one.png
style=width:80%;margin-left:auto;margin-right:auto;
id=sample_one
caption=Represents the two big spacers configuration in both Samples I and II.
caption=Represents the two big spacers configuration in both Samples I and II [!citep](cincotti2007sps).

!media media/cincotti_validation_images/sample_three.png
style=width:80%;margin-left:auto;margin-right:auto;
id=sample_three
caption=Represents the two big spacers, two small spacers, and one plunger configuration in Sample III.
caption=Represents the two big spacers, two small spacers, and one plunger configuration in Sample III [!citep](cincotti2007sps).

!media media/cincotti_validation_images/sample_four.png
style=width:80%;margin-left:auto;margin-right:auto;
id=sample_four
caption=Represents the two big spacers, two small spacers, one die and plungers configuration in Sample IV.
caption=Represents the two big spacers, two small spacers, one die and plungers configuration in Sample IV [!citep](cincotti2007sps).

Here is a cross-section visual of the SPS system:

Expand Down Expand Up @@ -167,59 +167,44 @@ In this section, results for each sample case will be discussed. Mesh and input

### Sample One

For sample one, the die assembly shown in [sample_one_2nd] was used. Thermal and electric contact resistance was simulated on either contact surface with the stainless steel electrodes, which had the geometry shown in [sps_schematic]. The current source was turned on at t = 0, held for 20 minutes, and then turned off. The assembly was then allowed to cool back to ambient temperature (293 K) for another 40 minutes.

!media media/cincotti_validation_images/sample_one.png
style=width:50%;margin-left:auto;margin-right:auto;
id=sample_one_2nd
caption=Sample one die assembly.
For sample one, the die assembly shown in [sample_one] was used. Thermal and electric contact resistance was simulated on either contact surface with the stainless steel electrodes, which had the geometry shown in [sps_schematic]. The current source was turned on at t = 0, held for 20 minutes, and then turned off. The assembly was then allowed to cool back to ambient temperature (293 K) for another 40 minutes.

!media media/cincotti_validation_images/sample_one_potential.png
style=width:50%;margin-left:auto;margin-right:auto;
id=sample_one_potential
caption=Electric potential results shown here.
caption=Electric potential results shown here [!citep](cincotti2007sps).

!media media/cincotti_validation_images/sample_one_temperature.png
style=width:50%;margin-left:auto;margin-right:auto;
id=sample_one_temperature
caption=Temperature results displayed here.
caption=Temperature results displayed here [!citep](cincotti2007sps).

Cincotti compensated for any deviation in properties in the COMSOL model by using the α and β parameters in the contact conductance calculation. These parameters were experimentally derived parameters. This deviation is much less evident in later sample cases, so the parameters were left unchanged for the remainder of the validation study. It is thus important to note that tuning of the current contact model cannot be neglected when accounting for variations in material properties and model parameters with the experimental setup. Benchmarking against a system of interest should be a first step in the process of using the code implemented here.

### Sample Three

For sample three, the die assembly shown in [sample_three] was used. Thermal and electric contact resistance was simulated on either contact surface with the stainless-steel electrodes, which had the geometry shown in [sps_schematic]. The current source was turned on at t = 0, held for 20 minutes, and then turned off. The assembly was then allowed to cool back to ambient temperature (293 K) for another 40 minutes. A two-dimensional view of the sample three assembly with contact interfaces highlighted is shown in [sample_three_2d].

!media media/cincotti_validation_images/sample_three.png
style=width:50%;margin-left:auto;margin-right:auto;
id=sample_three
caption=Sample three die assembly.

!media media/cincotti_validation_images/sample_three_2d.png
style=width:50%;margin-left:auto;margin-right:auto;
id=sample_three_2d
caption=2D view of sample three.
caption=2D view of sample three [!citep](cincotti2007sps).

Overall, results for both potential and temperature were in good agreement with the COMSOL model and decent agreement with Cincotti experimental data. Both codes had difficulty in the current model with resolving the cool-down period after the current source was turned off.

### Sample Four

For sample four, the die assembly shown in [sample_four] was used. Thermal and electric contact resistance was simulated on either contact surface with the stainless-steel electrodes, which had the geometry shown in [sps_schematic]. The current source was turned on at t = 0, held for 10 minutes, and then turned off. The assembly was then allowed to cool back to ambient temperature (293 K) for another 20 minutes.

!media media/cincotti_validation_images/sample_four.png
style=width:50%;margin-left:auto;margin-right:auto;
id=sample_four
caption=Sample four die assembly.

!media media/cincotti_validation_images/sample_four_potential.png
style=width:50%;margin-left:auto;margin-right:auto;
id=sample_four_potential
caption=Electric potential results shown here.
caption=Electric potential results shown here [!citep](cincotti2007sps).

!media media/cincotti_validation_images/sample_four_temperature.png
style=width:50%;margin-left:auto;margin-right:auto;
id=sample_four_temperature
caption=Temperature results displayed here.
caption=Temperature results displayed here [!citep](cincotti2007sps).

The potential results are shown in [sample_four_potential] with the temperature results shown in [sample_four_temperature]. Considering that sample four is the more geometrically “complicated” model under examination here, there are many horizontal surfaces nearby other vertical surfaces (and vice versa). As previously seen in both conducting and non-conducting powders, heat transfer from the surrounding domain is an important part of the SPS process, and some component of that is lost in this formulation.

Expand Down
1 change: 1 addition & 0 deletions doc/content/demonstration/index.md
Original file line number Diff line number Diff line change
Expand Up @@ -16,6 +16,7 @@ Problems and documentation that describe the basis of [MALAMUTE verification & v
are described in this section.

1. [verification/thermal_contact_verification.md]
2. [demonstration/electrothermal_contact_validation.md]

<!--TODO: These comments should be removed when example problems for MALAMUTE exist-->
!! ## Example Problems
Expand Down

0 comments on commit d18f3cb