- Phasing is the process in which the motor rotates 360 degrees in the CW direction once and we can determine the feedback offset angle
- 4 12V batteries in series connection were used to provide 48V(high voltage) to do the phasing process.
- RFE and RUN signal were given to the motorcontroller by attaching external push buttons
- First time testing videos
Steps:
-
Check that the switch in branch K4(discharge relay) is closed and has been closed for at least 15 seconds, once it has been closed for 15 sec, open the switch
-
Changes in the N-Drive software (installation guide attached in the end)
- Set Speed 2 at Pos-Reference to 100
- Set Inom eff in settings to 20A
- Set Mpole in settings to 20
- Set FB pole in settings to 2
- Set Mtemp to 32767(to resolve the motor temp issue value, for actual working the value must be set in between 14500-15000 which refers to 90-100 degree celcius)
- Set Imax pk to 3%
-
Give the RFE signal {It is mentioned in one of the emails that this can be done before applying the HV }
-
Close the switch in K3(negative AIR)
-
To initial Pre-Charge, close the switch in branch K2(Precharge relay)
-
Using the N-Drive Software determine when the DC-BUS is at least 90% of the total applied voltage (Check NDrive->Extra->Vdc-Bus (0xeb).
-
Once the DC-BUS voltage is at least 90% , close the switch in branch K1(Positive AIR) [It was not charged exactly to 90% but was actually showing around 50-51V even though the supply was only 48V]
-
Once the switch in branch K1(positive AIR) has been closed, open the switch in branch K2(Precharge)
-
High voltage is now being supplied to the motor controller and the system is considered live and should be handled carefully and cautiously
-
Changes in N-Drive software
- Auto ~> Special functions ~> select [fn4] Phasing-Rotating
- Press START (**The next step must be done before 10 s are over)
- Switch on X1-G (RUN: Run enable)
-
The motor must then rotate 360° once in CW direction.
-
Disable drive by switching X1-G (RUN) to off (NDrive will tell you) [ Please always deactivate the inverter with the RUN signal before cutting the HV voltage. Even at 48V.The RFE does not need to be disconnected. Disconnecting the RUN input is enough.]
- As seen in the EMRAX-RS_V2 Resolver connector pdf , the wire in the 6th pin of the Feedback plug motor is black-white but no black-white wire is there [Resolved(1)]
- After completing phasing, the N-drive software is supposed to give back the offset angle of our motor, but it gives a garbage value/whatever value you manually set in it
- As mentioned in the initialisation guide the motor is supposed to run during phasing at an Imax pk value of 5% it should draw a current of 2-3A {mentioned in emails by edward} however at 5% it draws 21.2A {as shown in phasing videos} and motor does not run at 5%[Resolved(3)]
- There were translation issues and the wire is supposed to be yellow-white
- We have custom made the connector ourselves by soldering the resistor as well as the connections
- We set the Imax pk value to 3% during our successfull test and the current drawn was 12.7A(as shown in N-drive software)
- The normal connections for battery pack(High voltage) connections are replaced by an external battery pack of 4 12V EXIDE batteries kept in series
- The controlling of the positive AIR which originally is done by a signal from the MASTER PCB(once 90% charging is done of the motor controller capacitor) was replaced by and external push button
- The RS232 serial interface requires a connector from M8 to D9-S. We have custom made the connector by soldering the wires into the RS232 connector.Special drivers are also required to be installed
- The resolver connections are as follow