I use this board as light switch/high load switch, for a long distant normal one could not reach and I can choose any high current relay and contactor for very high load.
The module include an external antena can reach 200m distant: Z-0001 by WEBEE.
- Connect relay control pin with P1.0.
- Connect your button with P0.0
Ready to flash with your tool download it here: dnckatsw001.hex
Please check: Zigbee2Mqtt
Download Z-Stack Home 1.2.2a it is free but require to register Z-Stack Home
Edit file C:\Texas Instruments\Z-Stack Home 1.2.2a.44539\Projects\zstack\HomeAutomation\SampleLight\Source\zcl_samplelight_data.c with those infor:
const uint8 zclSampleLight_ManufacturerName[] = { 6, 'D','N','C','K','A','T' };
const uint8 zclSampleLight_ModelId[] = { 11, 'D','N','C','K','A','T','_','S','0','0','1' };
const uint8 zclSampleLight_DateCode[] = { 16, '2','0','1','8','0','6','2','3',' ',' ',' ',' ',' ',' ',' ',' ' };
Add report state code to zclSampleLight_LcdDisplayUpdate:
//report state
zclSampleLightSeqNumState++;
zclReportCmd_t rptcmd;
rptcmd.numAttr = 1;
rptcmd.attrList[0].attrID = ATTRID_ON_OFF;
rptcmd.attrList[0].dataType = ZCL_DATATYPE_BOOLEAN;
rptcmd.attrList[0].attrData = (void *)(&zclSampleLight_OnOff);
// Set destination address to indirect
zclSampleLight_DstAddr.addrMode = (afAddrMode_t)Addr16Bit;
zclSampleLight_DstAddr.addr.shortAddr = 0;
zclSampleLight_DstAddr.endPoint=1;
zcl_SendReportCmd(SAMPLELIGHT_ENDPOINT,&zclSampleLight_DstAddr, ZCL_CLUSTER_ID_GEN_ON_OFF, &rptcmd, ZCL_FRAME_SERVER_CLIENT_DIR, true, zclSampleLightSeqNumState );
Disable ZCL_EZMODE and HOLD_AUTO_START build tag by add 'x' before each, and finally build and download to your module